 Space mounting clips  

18 inches (457mm) apart 

Attaching Contour Sections 

Starting from one end, attach the Tetra Contour LS to the  
mounting clips. Secure light guide by twisting tie-wire around  
the mounting clip and light guide.  

NOTE:  Wires can be concealed by tucking wires between  
mounting clips and Tetra Contour LS system.   

Must be used with Tetra 24 Volt 
Power Supplies. Refer to the 

Power 

  

 

 

Supply Installation Instructions 

for

 

more information on the power supply.

Install one mounting clip at each end and then a minimum  
of one mounting clip every 18 inches (457mm). 
NOTE:  Standard neon mounting hardware can also be used. 

Electrical Connections 

Planning 

For planning the layout, measure the perimeter of the building and divide by 8 ft. (2.44m) to determine the required quantity of Tetra  
Contour LS systems. See table  below for guidelines about cutting resolution.  
For seamless designs, accessories are available for straight runs and 90 degree corners. 
NOTE:  Do not use more than one suffix code for each respective application, as mixing suffix codes may result in appearance variation.  
Suffix code can be found on the packaging label. 

NOTE:  Tetra Contour LS is intended for straight runs.  

Insert wire connectors into weather 
box. Fill with electrical grade silicone 
and close box.  

NOTE: Examples of electrical grade 

silicone include

 

GE RTV 6700 Series 

Sealant, GE White Blanc RTV 162, Dow  
Corning 3145, Dow Corning RTV 748  

WARNING 

Risk of electrical shock. 

 Turn power OFF  

before inspection, installation or removal. 

CAUTION 

Risk of damage. 

 Must use electrical grade silicone. 

Secure the weather box using a         
#6 or #8 (M2 or M3) screw. 
NOTE:  When using twist - on  
connectors, weather box is required  
for all outdoor electrical connections. 

Weather box can be painted 

If it is necessary to cut the Tetra Contour LS for a better fit,  
refer to the Cutting Resolution table above. 
NOTE: Tetra Contour LS can only be cut on wires. 
NOTE:  Tetra Contour LS extension sections can only be cut  
on “Cut Here” markings. 

Electrical Grade Silicone 

If Tetra Contour LS sections are cut, apply electrical grade  
silicone to exposed wires and attach end cap. 

Tetra Contour LS extension 

Tetra Contour LS  

Tetra Contour LS 

Tetra Contour LS extension 

Cutting Resolution Table 

SKU 

Color 

Cutting Resolution 

GERDXNAA2 - RD 

Red 

2.67 inches (68mm) 

GEGLXNAA2 - GL 

Green 

2.00 inches (51mm) 

GEBLXNAA2 - BL 

Blue 

2.00 inches (51mm) 

GEWHXNAA2 - WH 

White 

2.00 inches (51mm) 

SKU 

Color 

Cutting Resolution 

GERDXNLA2 - RD 

Red 

8 inches (203mm) 

GEGLXNLA2 - GL 

Green 

8 inches (203mm) 

GEBLXNLA2 - BL 

Blue 

8 inches (203mm) 

GEWHXNLA2 - WH 

White 

8 inches (203mm) 

Continue attaching all the sections to the remaining  
mounting clips, leaving a 3/8 inch (10mm) gap between  
sections to allow for expansion or contraction. 

Plug together all adjacent Tetra Contour LS sections and  
tuck wires behind Tetra Contour LS sections or behind  
accessory pieces. 

3/8 in. (10mm) gap 

Using twist-on wire connectors,  
connect the white wire with red  
stripe (+) from the LED strip to the  
red wire (+) of the power supply.  
Connect the white wire (-) from the  
LED strip to the black wire (-) of the  
power supply. 
NOTE: Grounding and bonding  
must be done in accordance with  
National Electrical Code (Article  
600). See power supply instructions. 

White with  

red stripe (+) 

Red (+) 

White ( - ) 

Black ( - ) 

To power supply 

Run a wire from the power supply to  
a section of Tetra Contour LS. 
NOTE:  Power supply connection  
must be contained in an acceptable  
UL/NEMA enclosure. 

Power  

supply 

To Tetra Contour LS 

Red (+) 

Black ( - ) 

Cut off the quick connector on  
the Tetra Contour LS that you are  
connecting to the power supply. 

Содержание Tetra Contour LS

Страница 1: ...h red stripe of the LED strip to the red wire of the power supply and the white wire of the LED strip to the black wire of the power supply Troubleshooting RISK OF ELECTRIC SHOCK Turn power OFF before inspection installation or removal Properly ground Tetra Power Supply enclosure RISK OF FIRE Follow all NEC and local codes Use only UL approved wire for input output connections Minimum size 18 AWG ...

Страница 2: ...quired for all outdoor electrical connections Weather box can be painted 1 If it is necessary to cut the Tetra Contour LS for a better fit refer to the Cutting Resolution table above NOTE Tetra Contour LS can only be cut on wires NOTE Tetra Contour LS extension sections can only be cut on Cut Here markings Electrical Grade Silicone 2 If Tetra Contour LS sections are cut apply electrical grade sili...

Страница 3: ...quired for all outdoor electrical connections Weather box can be painted 1 If it is necessary to cut the Tetra Contour LS for a better fit refer to the Cutting Resolution table above NOTE Tetra Contour LS can only be cut on wires NOTE Tetra Contour LS extension sections can only be cut on Cut Here markings Electrical Grade Silicone 2 If Tetra Contour LS sections are cut apply electrical grade sili...

Страница 4: ...h red stripe of the LED strip to the red wire of the power supply and the white wire of the LED strip to the black wire of the power supply Troubleshooting RISK OF ELECTRIC SHOCK Turn power OFF before inspection installation or removal Properly ground Tetra Power Supply enclosure RISK OF FIRE Follow all NEC and local codes Use only UL approved wire for input output connections Minimum size 18 AWG ...

Отзывы: