DIAGNOSTIC STATUS CODES
TRANSISTOR PUMP CONTROL
Page 46
January 2000
Section 4.7 Pump Control Codes
PUMP
STATUS CODE
DESCRIPTION OF STATUS
CAUSE OF STATUS INDICATION
-117
“Card Type” selection is invalid.
This status code will be displayed when the card type
selection value is set to an invalid number.
MEMORY RECALL
NO
CORRECTIVE ACTIONS
TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Pump
Controller
SYMPTOM
Control will not operate.
POSSIBLE CAUSE
Invalid card type selection.
•
=
Review function 17 in the Handset
Instruction sheets. Adjust and set
card type value as instructed by OEM
service manual.
Verify that the correct logic card
catalog number is installed in the
controller.
NO
GRAPHIC
FOR THIS
STATUS CODE
PUMP
STATUS CODE
DESCRIPTION OF STATUS
CAUSE OF STATUS INDICATION
-127
Control logic card power supply is less
than 10 VDC.
This status code is displayed when the logic card
power supply is less than 10 volts.
MEMORY RECALL
YES
CORRECTIVE ACTIONS
TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Pump
Controller
SYMPTOM
Control will not operate.
POSSIBLE CAUSE
Discharged Battery
•
=
Check battery to insure proper state of
charge.
Loose connection at P1.
•
=
Insure that the wire connection at P1 is
tight.
Defective logic card
•
=
Replace control.
FU3
KEY SWITCH
P1 P2
FU2
POWER CONNECTIONS
POS
A1
NEG
A2
FI
E
L
D
A
R
MA
TURE
+
-
FU1
LINE