Safety Fuses - Electric Dryer
Both line wires to the dryer are over current protected by a 30 amp cartridge type
fuse. Before removing the access panel make sure power is disconnected to the
dryer. If either of these fuses are open, check resistance line to line and each line to
ground for possible shorts. Never just replace a fuse
without follow up testing. Power from the house circuit
comes in on the right side of the fuse holder.