Diagnostics
– Error Codes
Lid Lock Not Open/Close
Lid Lock (Service and Display to user)
This failure occurs when the lid can
not be locked or unlocked. The control
attempts 5 times to release or
lock the lid , if the lid is not released,
the control goes to pause state and
will wait 4.25 minutes to try
again to release or lock the lid, if the
lid continues without release or lock,
the control attempts one more time.
If the lid will still not release or lock,
the control goes to failure state.