– 62 –
Precise Fill Troubleshooting
Tr
oubleshooting
NO PRECISE FILL W
ATER
Does normal water
dispense work?
Does dispenser display
Is there
13.6 VDC
between red and black
wires on J4 at dispenser
board
Replace dispenser board
Check:
1.)
W
ater supply
2.)
W
ater valve
3.) Frozen water tank
4.) Wiring between water valve and main control board
5.) Main control board
Ye
s
No
No
Ye
s
No
Check:
1.) Wiring between dispenser and main control board
2.) Wire connector at bottom of freezer door
3.) Main control board
Is there 13.6 VDC
between red and black
wires on flowmeter
Ye
s
Check:
1.) Wiring between flowmeter and J14 on main control board
2.) Main control board
No
Is there 6.5 -7 VDC
between red and white
wires on flowmeter when
1st activated
Ye
s
Replace flowmeter
Note:
If no water is flowing through the flowmeter or no
communication is occurring between the flowmeter
and the main control board, the dispenser will display
“0” and beep after 2 seconds.
No
Check:
1.) Wiring between flowmeter and main control board
2.) Main control board
Ye
s
ST
ART
light up?
Does ice dispense
activate auger motor?
Ye
s
No
Check:
1.) Freezer door switch
2.) Dispenser switch
3.) Wiring connections at bottom of freezer door