– 48 –
To remove the fl owmeter:
Caution:
It may be necessary to bend the process
tube in order to remove the water valve. If it is
necessary to bend the process tube, use extreme
caution.
Remove the ¼-in. hex-head screw that holds the
water valve to the cabinet.
Lift and move the valve to the right to disengage
the tab at the top of the valve.
1.
2.
Note:
The fl owmeter is attached to a mounting
bracket that is held to the cabinet with a ¼-in. hex-
head screw and 2 tabs.
Note:
When replacing or repairing the water line
tubing, ensure the end of the tubing is cut
square and fully inserted into the water valve
and fl owmeter.
Do not discard mounting bracket. The mounting
bracket is not available as a replacement part.
•
•
Process Tube
Water Lines
Wire Harness
Outlet Tube
Inlet Tube
Flowmeter
The fl owmeter is located in the machine
compartment behind the water valve. The water
valve must be removed to access the fl owmeter.
Lift and rotate the fl owmeter bracket
counterclockwise to disengage the 2 tabs at the
top of the bracket.
Carefully pull out the bracket and fl owmeter.
Disconnect the water lines from the fl owmeter.
Disconnect the wire harness from the fl owmeter.
Remove three ¼-in. hex-head screws from the
mounting bracket.
4.
5.
6.
7.
8.
Remove the ¼-in. hex-head screw from the
fl owmeter bracket.
3.
Outlet Tube
Inlet Tube