background image

Installation Instructions

10

STEP 14 CONNECT WATER SUPPLY

Connect water supply line to the 90° elbow.

• Slide compression nut, then ferrule over end of water line.
• Insert water line into 90° elbow.
• Slide ferrule against elbow and secure with compression nut.

IMPORTANT

 – Check to be sure that door spring 

does not rub or contact the fill hose or water supply line. Test 
by opening and closing the door. Reroute the lines if a rubbing 
noise or interference occurs.

Figure EE

Figure FF

STEP 15 CONNECT DRAIN LINE

FOLLOW ALL LOCAL CODES AND ORDINANCES.

The molded end of the drain hose will fit 5/8" through 1" 
diameter inlet ports on the air gap, waste tee or disposer.
• Determine size of inlet port
• Cut drain hose connector on the marked line, if required, to fit 

the inlet port.

• If a longer drain hose is required, add up to 42" of length for 

a total of 10' to the factory installed hose. Use 5/8" or 7/8" 
inside diameter hose and a coupler to  
connect the two  
hose ends.  
Secure the  
connection with  
hose clamps.

Figure GG

• Secure the drain hose to the air gap, waste tee or disposer 

with clamps.

Note:

 TOTAL DRAIN HOSE LENGTH MUST NOT EXCEED 10' FOR 

PROPER DRAIN OPERATION.

DRAIN LINE INSTALLATION

• Connect drain line to air gap, waste tee or disposer using 

either previously determined method.

Waste Tee Installation

Figure HH

�������

�������

Disposer Installation

Waste Tee Installation

Figure JJ

Disposer Installation

Method 2 – Drain Hose Routing

Route the drain hose of the dishwasher to a minimum height of 32" from 
the floor with the supplied hanger as shown.

IMPORTANT

 – When connecting  

drain line to disposer, check to be sure  
that drain plug has been removed.  
DISHWASHER WILL NOT DRAIN IF  
PLUG IS LEFT IN PLACE.

Tip:

 Avoid unnecessary service call charges. Always be sure 

disposer drain plug has been removed before attaching 
dishwasher drain hose to the disposer.

������

������

����

�������

90

°

Elbow

90

°

Elbow

Ferrule

Door Spring

Hot Water

Supply Line

Compression Nut

05A-1183CC

����������

�������

����������

����������

923-10A

Cutting Line

1"

5/8"

IMPORTANT:

Do not cut corrugated

portion of hose

18"

Min.

32"

Min.

05A-1183GG

Fasten drain hose at least at

32" height with hanger supplied

IMPORTANT

 

– Either one of the above methods 

must be used or dishwasher will not operate properly.

Method 1 – Air gap with waste tee or disposer

Insert the drain hose to air gap as shown.

32"

Min.

18"

Min.

05A-1183FF

Fasten drain hose at least at

32" height with hanger supplied

Содержание Profile PDW8680N

Страница 1: ...acket or front brace depending on the model The 10 hex head screw is packaged in a small bag within the user bag Use these parts when making electrical connections 2006 General Electric Company Pub No...

Страница 2: ...L WASH SPEED CYCLE CHINA CRYSTAL RINSE ONLY 2 4 8 DELAY HOURS ADDED HEAT PRE WASH HEATED DRY READ CAREFULLY KEEP THESE INSTRUCTIONS PDW8200 Series PDW9200 Series PDW8400 Series PDW9700 Series PDW8700...

Страница 3: ...e tee for house plumbing if applicable Electrical cable or power cord if applicable Screw type hose clamps Strain relief for electrical connection Hand shut off valve Water line 3 8 min copper Coupler...

Страница 4: ...r disposer connection is less than 18 above floor to prevent siphoning DETERMINE DRAIN METHOD The type of drain installation depends on the following questions Do local codes or ordinances require an...

Страница 5: ...he cable must be routed as shown in Figure E Cable must extend a minimum of 24 from the rear wall For power cord connections install a 3 prong grounding type receptacle in the sink cabinet rear wall 6...

Страница 6: ...ptional but strongly recommended and may be required by local codes Water connection is on the left side of the dishwasher Install the hot water inlet line using no less than 3 8 copper tubing Route t...

Страница 7: ...r PDW9700 series and PDW9900 series otherwise proceed to Step 6 Remove the 2 toekick brace screws from the upper set of mounting holes and toekick brace Set aside for use in Step 19 Figure J STEP 3 RE...

Страница 8: ...t aside earlier and remove hose clamp attached to hose Be careful not to damage the drain hose Slip the hose clamp over the pump end of the hose Figure R STEP 10 SLIDE DISHWASHER PARTIALLY INTO CABINE...

Страница 9: ...hwasher as shown in Figure U Leave a 1 2 minimum gap between the underside of the countertop and the top of the dishwasher door as shown in Figure X Note For flush installations of the PDW9700 Series...

Страница 10: ...in the correct position shown in Step 11 Figure Y Figure Z STEP 13 SECURE DISHWASHER TO COUNTERTOP OR CABINET In this step you will need the 2 Phillips special head screws set aside prior to Step 1 T...

Страница 11: ...Note TOTAL DRAIN HOSE LENGTH MUST NOT EXCEED 10 FOR PROPER DRAIN OPERATION DRAIN LINE INSTALLATION Connect drain line to air gap waste tee or disposer using either previously determined method Waste...

Страница 12: ...See Step 2 Figure H If door drops or closes when released adjust spring tension Check to be sure that wiring is secure under the dishwasher not pinched or in contact with door springs or other compone...

Страница 13: ...ck drain lines If leaks are found turn off power at the breaker and correct plumbing as necessary Restore power after corrections are made See Step 8 and 15 Open dishwasher door and make sure most of...

Страница 14: ......

Страница 15: ......

Страница 16: ......

Страница 17: ...sumer Industrial General Electric Company Louisville Kentucky 40225 ge com 2005 General Electric Company Pub No 31 30588 Dwg No 206C1559P127 ND 05A 1183 2 05 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT N...