![GE Profile PB975 Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/ge/profile-pb975/profile-pb975_technical-service-manual_2200522051.webp)
– 51 –
Tuck the insulation up under the 2 wire
5.
insulation retainers.
Disconnect the two wires from the bake element
6.
terminals.
Remove two ¼” hex-head screws securing the
7.
ground wire and the bake element to the frame
of the range.
Grasp the bake element on both sides and
8.
gently pull it towards you as you remove it from
the frame.
Disconnect
Note:
Upon reassembly, ensure displaced insulation
around oven and components is returned to its
original position.
The probe outlet is held in place with two ¼-in. hex-
head screws.
After removing the two ¼-in. hex-head screws, the
outlet and wiring can then be pulled down from the
oven wall approximately 3 inches.
Note:
When replacing the meat probe outlet, cut
the probe wires and splice the new probe using
approved heat resistant connectors.
Meat Probe and Outlet (PB975)
The lower oven is equipped with a meat probe
outlet. The meat probe outlet is connected to
the lower oven control board in the control
compartment at location J6. The meat probe has a
resistance value of 30K-50K
Ω
at room temperature.
The probe outlet is accessed through a cutout near
the front right side of the broiler shield.
Cutout