64
Error Codes (cont.)
•Check integrity of wiring and connections between main
control and Door Lock mechanism.
•Investigate Door Lock mechanism; check door microswitch
operation, lock and unlock solenoid continuity and contact
integrity; replace Door Lock mechanism if necessary.
•IF ABOVE STEPS DO NOT CLEAR THE PROBLEM:
•Replace the main control.
Door Lock Assembly
Problems
E11 Door Lock
E12 Door Unlock
E13 Door Open
E28 Unexpected
Door Unlock
Detected
•Check integrity of wiring and connections between main
control and motor drive.
•Clear error code and run a cycle.
•If fault persists and reappears, replace the Machine Control.
Communication
Problem Between
Machine Control and
Motor Drive
E10 Motor
Communication
Interface
Action
Description
Error Code