62
Error Codes (cont.)
•Ensure manual water valves are fully open.
•Check if water strainers on solenoid valve assembly
are clogged.
•Check for obstructions inside inlet water hoses.
•Ensure solenoid valves do not leak when the valves are
de-energized and the washer is powered down.
•Measure coil resistance for both valves. If outside
range (1000–1250 ohms at room temp.), replace
solenoid valve assembly.
IF ABOVE STEPS DO NOT CLEAR THE PROBLEM:
•Replace solenoid valve assembly.
Fill Problem
E7 Slow Fill
•Check integrity of wiring and connections between
main control and Water Level Sensor.
•Check integrity of Water Level Sensor; replace if
necessary.
•Check drain system.
IF ABOVE STEPS DO NOT CLEAR THE PROBLEM:
•Replace the main control.
Water Level Sensor
Problem
E6 Pressure
Switch
Action
Description
Error Code
CONFIDENTIAL AND PROPRIETARY INFORMATION-NOT FOR PUBLIC DISCLOSURE. September 2008