63
Error Codes (cont.)
•. Check for obstruction in dispenser mechanism and linkages.
•Check the electrical connections at the motor feedback switch
and in the harness.
•Check the electrical connections of water valves in the
harness.
IF ABOVE STEPS DO NOT CLEAR THE PROBLEM:
•Replace dispenser motor assembly.
Dispenser
Problem
E9
Dispenser
Motor
•Ensure pump strainer is clean and free of debris.
•Check for obstruction inside the drain hose.
•Check pump impeller blades and bearing; if evidence of blade
damage or seized bearings are present, replace the pump.
•Check the electrical connections at the pump motor and
harness.
•Measure pump motor resistance. If outside range (9–14 ohms
at room temp.), replace the pump.
Drain Problem
E8 Drain
System
Action
Description
Error Code