GE Pro Elite 268-716-150-1248 Скачать руководство пользователя страница 25

25

Cycle Sequence Table

C# 

 Cycle Description

Time in Minutes

C0

Service

C4*

Repressurize

3

C8

Brine Refill 

Calculated

C0

Brine Make-up

120

C1

Backwash

14

C2

Brine Draw

Calculated

C3

Slow Rinse

Calculated

C4*

2nd Repressurize

3

C5

Fast Rinse

6

C6

2nd Backwash

1

C7

2nd Fast Rinse

1

*Note: C4 repressurization does not have flow to drain.

6.  Fill the media tank with water.

A.  While the controller is in the backwash (C1) 

cycle, open the water supply valve very slowly 

to approximately the 1/4 open position.

 

WARNING: If opened too rapidly or too 

far, media may be lost out of the tank 

into the valve or the plumbing. In the 1/4 

open position, you should hear air slowly 

escaping from the valve drain line.

B.  When all of the air has been purged from the 

media tank (water begins to flow steadily from 

the drain line), open the main supply valve all of 

the way. This will purge the remaining air from  

the tank.

C.  Allow water to run to drain until the water runs 

clear from the drain line. This purges any refuse 

from the media bed. 

D.  Turn off the water supply and let the system 

stand for about five minutes. This will allow any 

air trapped to escape from the tank. 

7.  Add water to the regenerant tank (conditioner only).

A.  With a bucket or hose, add enough water to 

the regenerant tank to have water visable.

Note: We recommend that you do not put regenerant 

into the tank until after the control valve has been put 

into operation. With no regenerant in the tank, it is 

much easier to view water flow and motion in the tank.

8.  Press and hold the SET and UP button for five seconds 

to cancel regeneration, and cycle the control back to 

the service position. 

9.  Start another regeneration. Advance the controller to 

the brine refill position (C8) to prime the line between 

the regenerant tank and the valve (conditioner only).

A.  Slowly open the main water supply valve again 

to the fully open position. Be sure not to open 

too rapidly, as that would push the media out 

of the media tank.

Note: As you advance through each cycle, there will be 

a slight delay before you can advance to the next cycle. 

There will be a pause after the brine draw and slow 

rinse cycles (system pause). This cycle allows the water/

air pressure to equalize on each side of the valve discs.

B.  With the water supply completely open, when 

you arrive at the brine tank refill cycle, the 

controller will direct water down through the 

line and into the tank. Watch the bottom of 

the tank until all air bubbles have been purged 

from the line and the water level is rising.

C.  Let the water flow down the line to the tank 

only until the rising water is visible.

D.  Simultaneously press and release the SET and 

UP buttons to advance to the Brine Make-up 

cycle. After the Brine Make-up cycle is reached, 

press the SET and UP buttons to advance to 

the Brine Draw/Slow Rinse cycle.

10.  Draw water from the regenerant tank.

A.  With the controller in this position, check to see 

that the water in the regenerant tank is being 

drawn out of the tank. The water level in the 

tank should recede very slowly.

B.  If the water in the regenerant tank does not 

recede, or goes up, refer to the Troubleshooting 

section.

11.  If the water level is receding from the regenerant 

tank, wait for the tank check valve to stop the water 

flow. Press the SET and UP buttons to advance the 

controller back to the treated water position.

12.  Finally, turn on a faucet plumbed after the water 

conditioner. Run the faucet until the water runs clear.

The Water Conditioning System is Now 

Fully Operational.

Содержание Pro Elite 268-716-150-1248

Страница 1: ...Pro Elite Professional Series Water Treatment System by GE Operation Manual Pro Elite Analyzer...

Страница 2: ...Cursors 17 Button Functions 17 Programming Overview 18 Analyzer Control Operation 18 Level I Programming 18 Level l Programming Analyzer Conditioner 19 Level II Programming P Values 20 Programming the...

Страница 3: ...d to minimize the amount of regenerant brine and water used in its operation Efficiency rated water softeners shall have a rated salt efficiency of not less that 3350 grains of total hardness exchange...

Страница 4: ...ghtened plumber tape may be used on connections that do not use an O ring seal Do not use pipe dope type sealants on the valve body Do not use pliers or pipe wrenches Do not use petroleum based lubric...

Страница 5: ...x 36 48 3 x 91 5 cm 19 x 36 48 3 x 91 5 cm Salt Storage 240 lbs 109 kg 240 lbs 109 kg 240 lbs 109 kg Drain Water Rate 2 7 gpm 10 2 L m 3 9 gpm 14 7 L m 3 9 gpm 14 7 L m Service Connection Size 1 NPT 1...

Страница 6: ...conditioner be installed in a protected environment When installing the water conditioning system outdoors several items must be considered Moisture The valve and control are rated for NEMA 3 locatio...

Страница 7: ...nism 3 Jacket Resin Tank 11 Tank Collar 4 Base 12 Riser Tube 5 268 Logix PE Valve w 716 Control 13 Upper Basket 6 Resin Tank 14 Cover 7 Door Access Sensor 15 Shield 8 Sensors Wired Probes Brine Tank 1...

Страница 8: ...8 Equipment Installation Dimensions 36 9 938 1 60 7 1541 6 28 2 715 9 32 2 817 5 53 4 1356 6 55 1398 1 5 0 127 2 5 63 5...

Страница 9: ...Floor Drain Figure 1 Standard Basement Before Installation Cold water lines shown Soft Water Hard Water Outside Faucet Outside Faucet Bath Tub Lavatory Toilet Kitchen Laundry Tubs Pump or Meter Hot W...

Страница 10: ...y the cover aside for now To Assemble the Media Tank 1 If the floor under the media tank is uneven the leveling feet may be installed Slowly lay the tank on its side Press or tap the feet into the poc...

Страница 11: ...B Y P A S S B Y P A S S Water Conditioner Water Conditioner In Out In Out Figure 7 Model 1265 Bypass Included Water Conditioner Water Conditioner Water Conditioner Water Conditioner Normal Operation I...

Страница 12: ...drain line connection This will provide an adequate siphon trap Tie or wire the hose in place at the drain point Also provide an air gap of at least 1 1 2 inch between the end of the hose and the drai...

Страница 13: ...ure hose in place Drain Air Gap Figure 12 Electrical Connection Note There are no user serviceable parts in the AC adapter motor or the control board The Analyzer control operates on a 12 volt alterna...

Страница 14: ...enerant draw is completed when the air check closes Slow Rinse Downflow Cycle C3 Water flow moves the regenerant through the resin at a specific rate and rinses to the drain The resin is regenerated R...

Страница 15: ...optical sensor which is rotated approximately 90 degrees out of phase Note If electrical power is not available the camshaft can be rotated counterclockwise by hand if the motor is removed Cycle Indic...

Страница 16: ...sed such as those sold for commercial laundries adjust the dosage accordingly 1 Dosage Polystyrene resin 1 2 fluid ounce 35 5 mL per cubic foot Non resinous exchangers 0 8 fluid ounce 23 7 mL per cubi...

Страница 17: ...as a solid icon during regeneration 12 When hourglass is flashing this indicates that the control is moving to a regeneration cycle Appears as a solid icon during a cancelled regeneration and the cont...

Страница 18: ...formation in memory for 8 to 24 hours depending on the installation If the super capacitor is exhausted the Analyzer control will display four dashes immediately upon power up The Time of Day and Day...

Страница 19: ...ress then or press press then PM Cubic feet 1 0 to 2 0 Lbs ft 3 Time Day Regeneration Time Day Time Day Regeneration Time Day Time Day Regeneration Time Day Time Day Regeneration Time Day Time Day Reg...

Страница 20: ...lt Setting 3 18 50 290 1 10 9 110 Lbs Cu ft3 g L Set in Level I Programming P7 Capacity View Only 1 140 0 1 14 0 1 0 1 Calculated Kilograins Kilograms Values dependent on P9 setting P8 Not Used P9 Uni...

Страница 21: ...Flow rate dictated by size of drain line flow controller C2 Regenerant Draw Not Adjustable 1 Min See Notes Automatically calculated from resin volume and salt dosage settings C3 Slow Rinse 0 200 1 Min...

Страница 22: ...n for three seconds while H4 number of regenerations since last reset is being displayed will reset the numbers stored in H4 H5 H6 H7 and H8 Holding the set key down for three seconds while H9 months...

Страница 23: ...rol reaches the backwash cycle the hourglass is no longer displayed and the motor will turn off Pressing the SET button will display the time remaining for the current cycle 4 Fill the media tank with...

Страница 24: ...h the control in the treated water position press and hold the REGEN button on the control for five seconds This will initiate a manual regeneration The control will display an hourglass indicating th...

Страница 25: ...her regeneration Advance the controller to the brine refill position C8 to prime the line between the regenerant tank and the valve conditioner only A Slowly open the main water supply valve again to...

Страница 26: ...immediate manual regeneration A solid regeneration icon will be displayed The control will immediately begin a regeneration Delayed Second Regeneration Pressing and releasing the REGEN button while th...

Страница 27: ...27 Pro Elite Valve Exploded View and Parts List BYPASS BYPASS 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17 18 19 11 12...

Страница 28: ...18 1010154 O Ring Tank 1 4000585 Skirt Pro Elite Lt Gray 1 19 1232370 O Ring Riser Tube 1 8 1000811 Transformer 120 VAC 60 Hz N American Plug 1 20 4001033 Probe Cable Clips Kit 1 9 3019221 Motor Optic...

Страница 29: ...29 19 21 22 23 24 25 2 3 4 5 6 7 9 10 12 13 14 15 16 17 18 11 Conditioner Tank and Regenerant Tank Assembly Exploded View and Parts List 1 A A A 26 20 8 27 28 5 26 29...

Страница 30: ...tton GE Logo 1 4 1 26 1234170 Screw 8 18 x 9 16 Type 25 4 10 4000347 Cover Brine Tank Pro Elite 1 27 4001265 Washer Countersunk Finishing SS 4 11 4000348 Collar Brine Tank Pro Elite 1 28 4001266 Screw...

Страница 31: ...CH15024 Cap Brine Well 4 Dia Caplug STP 4 1 6 60068 8 06 Brine Float w One Grommet As Purchased 1 7 60002 27 Air Check Assembly 1 8 BR10332 Tubing Insert Brass 2 CH20774 Overflow Fitting Assembly 1 CH...

Страница 32: ...ical sensor is connected and in place Verify that motor gear has engaged cam gear If everything is connected try replacing in this order 1 Wire harness motor optical sensor assembly 2 Control Camshaft...

Страница 33: ...ing to instructions b Remove restriction c Clean injector and screen d Replace injector and cap Contact dealer e Remove foreign matter from disc and check disc for closing by pushing in on stem Replac...

Страница 34: ...Pentair Residential Filtration LLC 5730 North Glen Park Road Milwaukee WI 53209 4454 USA 262 238 4400 Phone 262 238 4402 Fax 2011 Pentair Residential Filtration LLC P N 4001051 Rev D MR14...

Отзывы: