21
Level lll Cycle Programming – C Values
Several Level III program parameters can be adjusted
to fine-tune a conditioner's operation for non-standard
applications. Typically these parameters will not need to
be adjusted, as the default settings accommodate most
applications. Contact your Water Treatment Professional
before attempting any programming. The parameters
are accessible by pressing and holding the UP and SET
buttons until the display shows a “C” value.
Note: The control must be in the treated water position
to change settings.
C#
Description
Range
Minimum
Increments
Default
Setting
Notes
C1 Backwash
0 – 200
1 Min
10
Flow rate dictated by size of drain line
flow controller
C2 Regenerant Draw
Not
Adjustable
1 Min
See Notes
Automatically calculated from resin
volume and salt dosage settings
C3 Slow Rinse
0 – 200
1 Min
See Notes
Automatically calculated from resin
volume and salt dosage settings
C4 Repressurization
0 – 200
1 Min
3
Allows system to equalize water
pressure across valve discs
C5 Fast Rinse
0 – 200
1 Min
4
Rinses residual regenerant from tank
C6 2nd Backwash
0 – 200
1 Min
1
Disperses non-regenerated areas of the
resin bed
C7 2nd Fast Rinse
0 – 200
1 Min
1
Rinses to Quality
C8 Regenerant Refill
Not
Adjustable
1 Min
See Notes
Automatically calculated from resin
volume and salt dosage settings
C0 Service/Brine Prep
0 - 200
1 Min
120
Used in fill first models only. Brine prep
allows brine to come up to concentration
after refill.