3–8
PQMII POWER QUALITY METER – INSTRUCTION MANUAL
CHAPTER 3: OPERATION
3.4
Default Messages
3.4.1
Description
Up to 10 default messages can be selected to display sequentially when the PQMII is left
unattended. If no keys are pressed for the default message time in the
S1 PQMII SETUP
Ö
PREFERENCES
Ö
DEFAULT MESSAGE TIME
setpoint, then the currently displayed message will
automatically be overwritten by the first default message. After three seconds, the next
default message in the sequence will display if more than one is selected. Alarm messages
will override the default message display. Any setpoint or measured value can be selected
as a default message.
Messages are displayed in the order they are selected.
3.4.2
Adding a Default Message
Use the
MESSAGE
keys to display any setpoint or actual value message to be added to the
default message queue and follow the steps shown below. When selecting a setpoint
message for display as a default, do not modify the value using the
VALUE
keys or the
PQMII will recognize the
ENTER
key as storing a setpoint instead of selecting a default
message
If 10 default messages are already selected, the first message is erased and the new
message is added to the end of the queue.
3.4.3
Deleting a Default Message
Use the
MESSAGE
keys to display the default message to be erased. If default messages
are not known, wait until the PQMII starts to display them and then write them down. Use
the
MESSAGE
keys to display the setpoint or actual value message to be deleted from the
default message queue and follow the steps below.
THREE
P
HASE REAL
P
OWER =
1000 kW
TO ADD THIS DEFAULT
MESSAGE
P
RESS
ENTER
NEW DEFAULT
MESSAGE SELECTED
ACTUAL VALUE OR SETPOINT
TO BE STORED AS DEFAULT
MESSAGE
DISPLAYED FOR 3 SECONDS
WHEN STORE KEY PRESSED
TWICE
DISPLAYED FOR 3 SECONDS
WHEN STORE KEY PRESSED
AD
EF
MSG
.
CDR
ENTER
ENTER
ENTER
Содержание PQM II
Страница 8: ...TOC VI PQMII POWER QUALITY METER INSTRUCTION MANUAL TABLE OF CONTENTS ...
Страница 12: ...1 4 PQMII POWER QUALITY METER INSTRUCTION MANUAL CHAPTER 1 OVERVIEW FIGURE 1 2 Feature Highlights ...
Страница 19: ...CHAPTER 1 OVERVIEW PQMII POWER QUALITY METER INSTRUCTION MANUAL 1 11 FIGURE 1 9 Trace Memory Capture ...
Страница 58: ...3 10 PQMII POWER QUALITY METER INSTRUCTION MANUAL CHAPTER 3 OPERATION ...
Страница 78: ...4 20 PQMII POWER QUALITY METER INSTRUCTION MANUAL CHAPTER 4 SOFTWARE FIGURE 4 6 Voltage Disturbance Recorder ...
Страница 84: ...4 26 PQMII POWER QUALITY METER INSTRUCTION MANUAL CHAPTER 4 SOFTWARE ...
Страница 170: ...6 32 PQMII POWER QUALITY METER INSTRUCTION MANUAL CHAPTER 6 MONITORING ...
Страница 196: ...7 26 PQMII POWER QUALITY METER INSTRUCTION MANUAL CHAPTER 7 APPLICATIONS ...
Страница 198: ...8 2 PQMII POWER QUALITY METER INSTRUCTION MANUAL CHAPTER 8 WARRANTY ...
Страница 208: ...A 10 PQMII POWER QUALITY METER INSTRUCTION MANUAL APPENDIX A ...
Страница 216: ...B VIII PQM POWER QUALITY METER INSTRUCTION MANUAL CHAPTER B INDEX ...