Care and cleaning–RO cartridge replacement.

www.GEAppliances.com

Flow Control and Screen 

The flow control regulates the flow of water

through the Reverse Osmosis cartridge at the

required rate so high quality product water 

is produced.
When servicing the Reverse Osmosis

system, check the flow control and tubing to

it, to make sure the tube and surrounding

surfaces are clean and unrestricted. A small,

cone-shaped screen is located in front of the

flow control to help keep it clean. If the flow

control or screen is plugged with foreign

particles, the Reverse Osmosis cartridge

cannot discharge minerals and impurities

to the drain. If this happens, it will only take

a short time for the cartridge to plug,

making it useless.

Make sure the red tank shutoff valve is

closed, water supply valve is closed (turn

clockwise), and the RO water faucet is

open to the system. Drain system until

water stops flowing.
Locate the flow control and screen.

Remove the straight tubing from the 

top of the Reverse Osmosis system.

Remove the flow control from the end

of the tubing with a clean knife edge.

Remove the screen; a toothpick may 

be needed for the interior portion of 

the cap.

If you are replacing the flow control and

screen, discard them. If you are checking

the flow control, screen and tubing for

blockage, clean these parts of any debris.

Do not blow through the flow control. 

It will contaminate the part.

Replace the screen by placing the cone

end into the cap and carefully push it in.

CAUTION:

Do not force in further after

you feel resistance. Visually check to be

sure it is properly positioned. 

Install the flow control and tighten by

hand, then another 1/4 turn with pliers.

DO NOT OVERTIGHTEN AND DISTORT OR
CRUSH THE TUBING AND FLOW CONTROL.

If you are replacing the Reverse Osmosis

cartridge, return to the 

Reverse Osmosis

Cartridge Replacement

instructions.

Otherwise, open red tank shutoff 

valve and water supply valve (turn

counterclockwise). Close the RO 

water faucet.

7

6

5

4

3

2

1

Reverse
Osmosis cap

Cone
screen

Flow control

Reverse Osmosis Cartridge Replacement

NOTE: 

When replacing the Reverse Osmosis

cartridge, also install a new flow control and
screen.

It’s time to replace the Reverse Osmosis

cartridge when the amber “RO” light on the

faucet base flashes continually while Reverse

Osmosis water is taken from the faucet.

Follow steps 1 through 5 in the 

Remove

the Filters 

section.

Place the prefilter cartridge back in the

Reverse Osmosis housing. Note “THIS

END UP” on one end. Then slide the

new Reverse Osmosis cartridge into the

prefilter end with 2 o-rings first. Also

note “up” arrow on side. See 

Replace 

the Filter

section, step 1 for diagram. 

Remove and replace the flow control and

screen. See the 

Flow Control and Screen

section below.
Lightly lubricate the cap o-ring seal with

only clean silicone grease. Then, push the

cap into position and install the clamp

sections and retainers.
Turn on the water supply valve and

PURGE THE REVERSE OSMOSIS
CARTRIDGE. 

See the 

Purging the Reverse

Osmosis System

section on page 5.

CAUTION:

The Reverse Osmosis cartridge

contains a food grade preservative that
should be purged from the system before 
first use or whenever the Reverse Osmosis
cartridge is replaced. The preservative will
give product water an unpleasant 

taste 

and odor.

5

4

3

2

1

Содержание PNRV18ZCC01

Страница 1: ...ification Guidelines 3 Care and Cleaning Battery Replacement 10 Check the System 8 Filter Replacement Procedures 6 8 Flow Control and Screen 9 RO Cartridge Replacement 9 Sanitizing the System 7 10 Troubleshooting Tips Before You Call For Service 12 13 Common Problems 14 Consumer Support Consumer Support Back Cover Warranty 15 The GE RO PNRV18Z Model Series is Tested and Certified by NSF Internatio...

Страница 2: ...luent concentrations of no more than 27 mg L nitrate and 3 mg L nitrite in combination measured as N and is certified for nitrate nitrite reduction only for water supplies with a pressure of 280kPa 40 psig or greater SAVE THESE INSTRUCTIONS READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY Install or store where it will not be exposed to temperatures below freezing or exposed to any type of weathe...

Страница 3: ...n sulfide ppm 0 1 Chlorine in water supply Allowable Feed water pH limits pH 4 10 Percent rejection of TDS minimum new membrane 92 Chlorine removed maximum of 2 0 ppm by the Reverse Osmosis prefilter regular changing of the prefilter is required Chlorine will destroy the Reverse Osmosis membrane Feed water at 50 psig and 77 F with 750 ppm sodium chloride Quality water production amount of waste wa...

Страница 4: ...essurized for fast flow to the faucet when drinking water is needed Check Valve A check valve is built into the bottom end of the Reverse Osmosis housing The check valve prevents a backward flow of product water from the storage area A backward flow could cause rupture of the Reverse Osmosis membrane Automatic Shutoff Assembly To conserve water the drinking water system has an automatic shutoff Wh...

Страница 5: ...of the flashing RO light Long periods of limited or non use can cause the TDS levels to temporarily change If the Reverse Osmosis Filtration System Is Connected to Your Icemaker Before you service the filter change the filters or purge the Filtration system YOU MUST turn off the icemaker by raising the feeler arm Four hours after servicing your unit lower the feeler arm to resume icemaking Purging...

Страница 6: ...osis Filtration System is connected to your icemaker YOU MUST turn off the icemaker by raising the feeler arm before servicing the filter changing the filters or purging the filtration system After completing work allow four hours for unit to refill then lower the feeler arm to resume icemaking Pull the Reverse Osmosis system away from cabinet leave tubing connected Place a dry towel under the sys...

Страница 7: ...nnect to electronics box A small amount of water will drain when fitting is disconnected Remove the clamp retainers and sections from top of the unit Lift the Reverse Osmosis cap straight up slight resistance is normal from the Reverse Osmosis housing no need to disconnect tubing and move aside Dispose of water from the Reverse Osmosis housing NOTE If the cap o ring remained in the Reverse Osmosis...

Страница 8: ...x to bottom of postfilter Snap postfilter into holder The flow arrow printed on the side of the filter should be pointed down Replace batteries in battery case with four new AA alkaline batteries Note orientation and of batteries Weak batteries will give no or a false indication Replacing batteries also resets the six month clock and filter light will flash green NOTE Lights may not operate proper...

Страница 9: ...t force in further after you feel resistance Visually check to be sure it is properly positioned Install the flow control and tighten by hand then another 1 4 turn with pliers DO NOT OVERTIGHTEN AND DISTORT OR CRUSH THE TUBING AND FLOW CONTROL If you are replacing the Reverse Osmosis cartridge return to the Reverse Osmosis Cartridge Replacement instructions Otherwise open red tank shutoff valve an...

Страница 10: ...e Osmosis system and after servicing inner parts of the Reverse Osmosis system including replacement of prefilter postfilter and Reverse Osmosis cartridge It is important to wash hands with anti bacterial soap before handling inner parts of the system See the Sanitize the System section for instructions CAUTION If installing unit in New Construction ensure house plumbing is flushed thoroughly befo...

Страница 11: ...11 Consumer Support Operating Instructions Safety Instructions Care and Cleaning Troubleshooting Tips Notes www GEAppliances com ...

Страница 12: ...e Reverse Osmosis Replace the Reverse Osmosis membrane cartridge of this flashing light membrane is no longer flow control and screen removing the required amount of Total Dissolved Solids Water supply to the Reverse Increase water pressure precondition the water etc Osmosis system not within as needed to conform before doing maintenance on specifications the Reverse Osmosis system Incorrect brine...

Страница 13: ...Water leaking from Drain side of faucet air gap Inspect and eliminate restriction or plug It is important faucet air gap hole 3 8 tubing plugged that there are no dips loops or low spots in the drain line restricted or incorrectly from the faucet air gap to the drain pipe Refer to connected to the drain Installation Instructions for proper drain connection If drain line adapter was used as the dra...

Страница 14: ...ges Leak at fittings Use pliers to tighten fittings until leak stops Do not overtighten FILTER light flashes Batteries not changed Replace batteries See step 5 under Replace the Filters yellow When batteries are replaced the light will flash green and the 6 months timer will be reset RO light flashes Prefilter cartridge Remove RO cap and look at end of prefilter cartridge yellow assembled upside d...

Страница 15: ...ights and you may also have other rights which vary from state to state To know what your legal rights are consult your local or state consumer affairs office or your state s Attorney General Warrantor General Electric Company Louisville KY 40225 For The Period Of GE Will Replace One Year Any part of the Reverse Osmosis Filtration System which fails due to a defect in materials or From the date of...

Страница 16: ... about special discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories www GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes V...

Отзывы: