GE PNRV18ZCC01 Скачать руководство пользователя страница 4

About the reverse osmosis system.

UP

What the Reverse Osmosis System Does

Reverse Osmosis removes Total Dissolved Solids (TDS) and organic matter from water by
diffusing it through a special membrane. The membrane separates minerals and impurities
from the water and they are flushed to the drain. High quality product water goes directly 
to the drinking water faucet or to the storage tank. The system makes a good supply of
drinking water each day (see 

Specification guidelines

). How much it makes depends on the

feed water supply pressure, temperature and quality.
The system includes an electronic faucet assembly with an integrated water testing feature.

When water is taken from the faucet, a green indicator light means removal is within the

specified limits and water quality is good.
Prefilters and postfilters are replaceable cartridges. The carbon prefilter removes chlorine

while also filtering sediments. The postfilter removes any other undesirable tastes and 

odors before you use the water.

How the Reverse Osmosis System Works

Prefilter—

Water from the cold supply pipe enters the Reverse Osmosis assembly and 

is directed to the prefilter cartridge. 

NOTE: 

Before going to the prefilter, supply water first passes through the electronics box to

measure TDS.

The prefilter is a replaceable sediment cartridge with activated carbon in its composition.

The cartridge removes sand, silt, dirt, other sediments and up to 2.0 ppm of chlorine from

the feed water. The prefilter reduces chlorine in the feed water because 

CHLORINE DESTROYS

THE REVERSE OSMOSIS MEMBRANE. 

Filtered, clean, chlorine-reduced water flows from the

prefilter to the Reverse Osmosis membrane cartridge.

Product Water Storage—

The storage area holds up to 1.9 gallons of product water. 

The flexible bladder keeps water pressurized for fast flow to the faucet when drinking

water is needed.

Check Valve—

A check valve is built into the bottom end of the Reverse Osmosis housing.

The check valve prevents a backward flow of product water from the storage area. 

A backward flow could cause rupture of the Reverse Osmosis membrane.

Automatic Shutoff Assembly—

To conserve water, the drinking water system has an

automatic shutoff. When the storage tank has filled to capacity and the RO water faucet 

is closed, pressure closes the shutoff. Water flow to the Reverse Osmosis housing is 

shutoff until Reverse Osmosis water is used again, and pressure drops in the Reverse

Osmosis system.

Reverse Osmosis Cartridge—

The cartridge, inside the Reverse Osmosis housing, includes 

a tightly wound, special membrane. Water is forced through the cartridge where the

membrane removes the dissolved solids and organic matter. High quality product water

exits the Reverse Osmosis housing and goes to the storage area. Reject water, with the

dissolved solids and organic matter, leaves the housing and is discharged to the drain.

Postfilter—

After leaving the storage area, but before going to the faucet, product water

goes to the postfilter. The postfilter is also the activated carbon type sediment filter. 

Any remaining tastes, odors, or sediments are removed from product water. Clean, 

high quality drinking water flows through the tubing and to the faucet.

Flow Control—

The flow control regulates flow of water through the Reverse Osmosis

cartridge at the required rate to produce high quality water. The control is located in 

the drain tubing, at the Reverse Osmosis cap fitting. A small, cone-shaped screen fits over

the front end of the flow control to help prevent plugging with drain water sediments.

7

6

5

4

3

2

1

Further description of this illustration
is in the Care and Cleaning section.

6

1

1

2

3

4

5

7

Automatic
shutoff
assembly

4

Operating Instructions

Safety Instructions

Care and Cleaning

Troubleshooting T

ips

Consumer Support

Содержание PNRV18ZCC01

Страница 1: ...ification Guidelines 3 Care and Cleaning Battery Replacement 10 Check the System 8 Filter Replacement Procedures 6 8 Flow Control and Screen 9 RO Cartridge Replacement 9 Sanitizing the System 7 10 Troubleshooting Tips Before You Call For Service 12 13 Common Problems 14 Consumer Support Consumer Support Back Cover Warranty 15 The GE RO PNRV18Z Model Series is Tested and Certified by NSF Internatio...

Страница 2: ...luent concentrations of no more than 27 mg L nitrate and 3 mg L nitrite in combination measured as N and is certified for nitrate nitrite reduction only for water supplies with a pressure of 280kPa 40 psig or greater SAVE THESE INSTRUCTIONS READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY Install or store where it will not be exposed to temperatures below freezing or exposed to any type of weathe...

Страница 3: ...n sulfide ppm 0 1 Chlorine in water supply Allowable Feed water pH limits pH 4 10 Percent rejection of TDS minimum new membrane 92 Chlorine removed maximum of 2 0 ppm by the Reverse Osmosis prefilter regular changing of the prefilter is required Chlorine will destroy the Reverse Osmosis membrane Feed water at 50 psig and 77 F with 750 ppm sodium chloride Quality water production amount of waste wa...

Страница 4: ...essurized for fast flow to the faucet when drinking water is needed Check Valve A check valve is built into the bottom end of the Reverse Osmosis housing The check valve prevents a backward flow of product water from the storage area A backward flow could cause rupture of the Reverse Osmosis membrane Automatic Shutoff Assembly To conserve water the drinking water system has an automatic shutoff Wh...

Страница 5: ...of the flashing RO light Long periods of limited or non use can cause the TDS levels to temporarily change If the Reverse Osmosis Filtration System Is Connected to Your Icemaker Before you service the filter change the filters or purge the Filtration system YOU MUST turn off the icemaker by raising the feeler arm Four hours after servicing your unit lower the feeler arm to resume icemaking Purging...

Страница 6: ...osis Filtration System is connected to your icemaker YOU MUST turn off the icemaker by raising the feeler arm before servicing the filter changing the filters or purging the filtration system After completing work allow four hours for unit to refill then lower the feeler arm to resume icemaking Pull the Reverse Osmosis system away from cabinet leave tubing connected Place a dry towel under the sys...

Страница 7: ...nnect to electronics box A small amount of water will drain when fitting is disconnected Remove the clamp retainers and sections from top of the unit Lift the Reverse Osmosis cap straight up slight resistance is normal from the Reverse Osmosis housing no need to disconnect tubing and move aside Dispose of water from the Reverse Osmosis housing NOTE If the cap o ring remained in the Reverse Osmosis...

Страница 8: ...x to bottom of postfilter Snap postfilter into holder The flow arrow printed on the side of the filter should be pointed down Replace batteries in battery case with four new AA alkaline batteries Note orientation and of batteries Weak batteries will give no or a false indication Replacing batteries also resets the six month clock and filter light will flash green NOTE Lights may not operate proper...

Страница 9: ...t force in further after you feel resistance Visually check to be sure it is properly positioned Install the flow control and tighten by hand then another 1 4 turn with pliers DO NOT OVERTIGHTEN AND DISTORT OR CRUSH THE TUBING AND FLOW CONTROL If you are replacing the Reverse Osmosis cartridge return to the Reverse Osmosis Cartridge Replacement instructions Otherwise open red tank shutoff valve an...

Страница 10: ...e Osmosis system and after servicing inner parts of the Reverse Osmosis system including replacement of prefilter postfilter and Reverse Osmosis cartridge It is important to wash hands with anti bacterial soap before handling inner parts of the system See the Sanitize the System section for instructions CAUTION If installing unit in New Construction ensure house plumbing is flushed thoroughly befo...

Страница 11: ...11 Consumer Support Operating Instructions Safety Instructions Care and Cleaning Troubleshooting Tips Notes www GEAppliances com ...

Страница 12: ...e Reverse Osmosis Replace the Reverse Osmosis membrane cartridge of this flashing light membrane is no longer flow control and screen removing the required amount of Total Dissolved Solids Water supply to the Reverse Increase water pressure precondition the water etc Osmosis system not within as needed to conform before doing maintenance on specifications the Reverse Osmosis system Incorrect brine...

Страница 13: ...Water leaking from Drain side of faucet air gap Inspect and eliminate restriction or plug It is important faucet air gap hole 3 8 tubing plugged that there are no dips loops or low spots in the drain line restricted or incorrectly from the faucet air gap to the drain pipe Refer to connected to the drain Installation Instructions for proper drain connection If drain line adapter was used as the dra...

Страница 14: ...ges Leak at fittings Use pliers to tighten fittings until leak stops Do not overtighten FILTER light flashes Batteries not changed Replace batteries See step 5 under Replace the Filters yellow When batteries are replaced the light will flash green and the 6 months timer will be reset RO light flashes Prefilter cartridge Remove RO cap and look at end of prefilter cartridge yellow assembled upside d...

Страница 15: ...ights and you may also have other rights which vary from state to state To know what your legal rights are consult your local or state consumer affairs office or your state s Attorney General Warrantor General Electric Company Louisville KY 40225 For The Period Of GE Will Replace One Year Any part of the Reverse Osmosis Filtration System which fails due to a defect in materials or From the date of...

Страница 16: ... about special discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories www GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes V...

Отзывы: