Check with your state and local public works

department for plumbing and sanitation codes. 

You must follow these guidelines as you install 

the Reverse Osmosis system. 

Using a qualified

installer is recommended

.

If house water pressure is over the maximum 

(125 pounds per square inch), install a pressure

reducing valve in the water supply line to the

Reverse Osmosis system.

Be sure the water supply conforms with the

Specification guidelines.

If the water supply

conditions are unknown, contact your municipal

water company or your local health department for

a list of contaminants in your area and a list of

laboratories certified by your state to analyze

drinking water.

WARNING: 

Before using the Reverse Osmosis

system for the first time, the system must be purged.
The Reverse Osmosis cartridge contains a food
grade preservative that must be purged from the
system. The preservative will give product water 
an unpleasant taste and odor.

This product reduces fluoride in drinking water.

Please consult your dentist if you have questions.

WARNING: 

Do not use with water that is

microbiologically unsafe or of unknown quality
without adequate disinfection before or after the
system. Systems certified for cyst reduction may 
be used on disinfected water that may contain
filterable cysts. This system shall only be used for
arsenic reduction on chlorinated water supplies
containing detectable residual free chlorine at the
system inlet. Water systems using an in-line
chlorinator should provide a one minute chlorine
contact time before the RO system. This Reverse
Osmosis unit contains a replaceable membrane
cartridge treatment component critical for effective
reduction of Total Dissolved Solids. The water
should be tested periodically to verify that the
system is performing satisfactorily. This system is
acceptable for treatment of influent concentrations
of no more than 27 mg/L nitrate and 3 mg/L nitrite 
in combination measured as N and is certified for
nitrate/nitrite reduction only for water supplies 
with a pressure of 280kPa (40 psig) or greater.

SAVE THESE INSTRUCTIONS

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.

Install or store where it will not be exposed to

temperatures below freezing or exposed to any 

type of weather. Water freezing in the system will

break it. Do not attempt to treat water over 100°F.

Do not install on 

HOT WATER.

The temperature 

of the water supply to the Reverse Osmosis 

system must be between the minimum of 40°F.

and the maximum of 100°F. See the 

Specification

guidelines.

Do Not

open the water supply valve until the pipes

have been flushed.

Extended non-use of the Reverse Osmosis system

If the system is not used for one week or more,

open the RO water faucet, allow the system to

drain. Close the RO water faucet and allow the

system to regenerate the water supply.

WARNING: 

Discard all unused parts and

packaging material after installation. Small parts
remaining after the installation could be a choke hazard.

Sanitize upon installation of the Reverse Osmosis

system and after servicing inner parts, including

replacement of prefilter, postfilter and Reverse

Osmosis cartridge. It is important to have clean

hands while handling inner parts of the system. See

the 

Sanitizing the Reverse Osmosis System 

section.

IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.

WARNING!

For your safety, the information in this manual must be followed to minimize the risk of
property damage or personal injury.

SAFETY PRECAUTIONS

PROPER INSTALLATION AND MAINTENANCE

This Reverse Osmosis system must be properly installed and located in accordance with the
Installation 

Instructions before it is used. If you did not receive Installation Instructions, 

you can receive one by calling us toll-free at the GE Answer Center

®

, 800.626.2000.

2

Operating Instructions

Safety Instructions

Care and Cleaning

Troubleshooting T

ips

Consumer Support

Содержание PNRV18ZCC01

Страница 1: ...ification Guidelines 3 Care and Cleaning Battery Replacement 10 Check the System 8 Filter Replacement Procedures 6 8 Flow Control and Screen 9 RO Cartridge Replacement 9 Sanitizing the System 7 10 Troubleshooting Tips Before You Call For Service 12 13 Common Problems 14 Consumer Support Consumer Support Back Cover Warranty 15 The GE RO PNRV18Z Model Series is Tested and Certified by NSF Internatio...

Страница 2: ...luent concentrations of no more than 27 mg L nitrate and 3 mg L nitrite in combination measured as N and is certified for nitrate nitrite reduction only for water supplies with a pressure of 280kPa 40 psig or greater SAVE THESE INSTRUCTIONS READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY Install or store where it will not be exposed to temperatures below freezing or exposed to any type of weathe...

Страница 3: ...n sulfide ppm 0 1 Chlorine in water supply Allowable Feed water pH limits pH 4 10 Percent rejection of TDS minimum new membrane 92 Chlorine removed maximum of 2 0 ppm by the Reverse Osmosis prefilter regular changing of the prefilter is required Chlorine will destroy the Reverse Osmosis membrane Feed water at 50 psig and 77 F with 750 ppm sodium chloride Quality water production amount of waste wa...

Страница 4: ...essurized for fast flow to the faucet when drinking water is needed Check Valve A check valve is built into the bottom end of the Reverse Osmosis housing The check valve prevents a backward flow of product water from the storage area A backward flow could cause rupture of the Reverse Osmosis membrane Automatic Shutoff Assembly To conserve water the drinking water system has an automatic shutoff Wh...

Страница 5: ...of the flashing RO light Long periods of limited or non use can cause the TDS levels to temporarily change If the Reverse Osmosis Filtration System Is Connected to Your Icemaker Before you service the filter change the filters or purge the Filtration system YOU MUST turn off the icemaker by raising the feeler arm Four hours after servicing your unit lower the feeler arm to resume icemaking Purging...

Страница 6: ...osis Filtration System is connected to your icemaker YOU MUST turn off the icemaker by raising the feeler arm before servicing the filter changing the filters or purging the filtration system After completing work allow four hours for unit to refill then lower the feeler arm to resume icemaking Pull the Reverse Osmosis system away from cabinet leave tubing connected Place a dry towel under the sys...

Страница 7: ...nnect to electronics box A small amount of water will drain when fitting is disconnected Remove the clamp retainers and sections from top of the unit Lift the Reverse Osmosis cap straight up slight resistance is normal from the Reverse Osmosis housing no need to disconnect tubing and move aside Dispose of water from the Reverse Osmosis housing NOTE If the cap o ring remained in the Reverse Osmosis...

Страница 8: ...x to bottom of postfilter Snap postfilter into holder The flow arrow printed on the side of the filter should be pointed down Replace batteries in battery case with four new AA alkaline batteries Note orientation and of batteries Weak batteries will give no or a false indication Replacing batteries also resets the six month clock and filter light will flash green NOTE Lights may not operate proper...

Страница 9: ...t force in further after you feel resistance Visually check to be sure it is properly positioned Install the flow control and tighten by hand then another 1 4 turn with pliers DO NOT OVERTIGHTEN AND DISTORT OR CRUSH THE TUBING AND FLOW CONTROL If you are replacing the Reverse Osmosis cartridge return to the Reverse Osmosis Cartridge Replacement instructions Otherwise open red tank shutoff valve an...

Страница 10: ...e Osmosis system and after servicing inner parts of the Reverse Osmosis system including replacement of prefilter postfilter and Reverse Osmosis cartridge It is important to wash hands with anti bacterial soap before handling inner parts of the system See the Sanitize the System section for instructions CAUTION If installing unit in New Construction ensure house plumbing is flushed thoroughly befo...

Страница 11: ...11 Consumer Support Operating Instructions Safety Instructions Care and Cleaning Troubleshooting Tips Notes www GEAppliances com ...

Страница 12: ...e Reverse Osmosis Replace the Reverse Osmosis membrane cartridge of this flashing light membrane is no longer flow control and screen removing the required amount of Total Dissolved Solids Water supply to the Reverse Increase water pressure precondition the water etc Osmosis system not within as needed to conform before doing maintenance on specifications the Reverse Osmosis system Incorrect brine...

Страница 13: ...Water leaking from Drain side of faucet air gap Inspect and eliminate restriction or plug It is important faucet air gap hole 3 8 tubing plugged that there are no dips loops or low spots in the drain line restricted or incorrectly from the faucet air gap to the drain pipe Refer to connected to the drain Installation Instructions for proper drain connection If drain line adapter was used as the dra...

Страница 14: ...ges Leak at fittings Use pliers to tighten fittings until leak stops Do not overtighten FILTER light flashes Batteries not changed Replace batteries See step 5 under Replace the Filters yellow When batteries are replaced the light will flash green and the 6 months timer will be reset RO light flashes Prefilter cartridge Remove RO cap and look at end of prefilter cartridge yellow assembled upside d...

Страница 15: ...ights and you may also have other rights which vary from state to state To know what your legal rights are consult your local or state consumer affairs office or your state s Attorney General Warrantor General Electric Company Louisville KY 40225 For The Period Of GE Will Replace One Year Any part of the Reverse Osmosis Filtration System which fails due to a defect in materials or From the date of...

Страница 16: ... about special discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories www GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes V...

Отзывы: