GE PNRV18ZCC01 Скачать руководство пользователя страница 6

UP

Automatic shutoff assembly

Postfilter

Product water tubing
(goes to faucet)

Red tank
shutoff valve

Clamp
sections (2)

Reverse Osmosis 
housing

Top end “This
Side Up”

Flow
control

Cone screen

Reverse Osmosis cap

Green
protective cap

Vacuum
relief valve

Postfilter
line

Prefilter
cartridge

Reverse Osmosis cartridge

End with o-ring seals
downward

Clamp
retainers (2)

Care and cleaning–Filter replacement procedures.

To obtain replacement filters, call GE Appliance Parts at 800-626-2002.

You must replace the prefilter cartridge at least every six months to protect the Reverse Osmosis membrane

from being destroyed by chlorine and/or from plugging with sediments in the water supply valve.
It is time to replace the Reverse Osmosis cartridge when the amber “RO” light, on the faucet base, flashes

continually while Reverse Osmosis water is taken from the faucet.
To signal correct replacement interval for prefilter, postfilter and batteries, the amber “FILTER” indicator

light, on the electronic faucet base, will begin to flash after six months, or 900 gallons of product water use,

whichever occurs first.

Remove the Filters

Be sure you have cleaned your
hands with anti-bacterial soap
before handling inner parts of the
system.

Turn water supply valve to the

Reverse Osmosis system off;

turn clockwise. Turn RO faucet

on and allow tank to completely

drain (this will take a few

minutes).

NOTE:

If the Reverse Osmosis

Filtration System is connected to
your icemaker, YOU MUST turn off
the icemaker by raising the feeler
arm before servicing the filter,
changing the filters or purging the
filtration system. After completing
work, allow four hours for unit to
refill, then lower the feeler arm to
resume icemaking.

Pull the Reverse Osmosis

system away from cabinet;

leave tubing connected. Place

a dry towel under the system.
Remove the clamp retainers

and sections from top of unit.
Lift the Reverse Osmosis cap

straight up (slight resistance is

normal) from the Reverse

Osmosis housing (no need to

disconnect tubing) and move

aside.

NOTE:

If the cap o-ring remained

in the Reverse Osmosis housing,
replace it on the cap.

Remove the Reverse Osmosis

cartridge and the outer

prefilter cartridge from the

Reverse Osmosis housing and

place the Reverse Osmosis

cartridge in a clean plastic bag.

Discard the prefilter cartridge.

Dispose of water from the

Reverse Osmosis housing.
Turn off tank shutoff valve

(red color).

Disconnect tubing at both 

ends of postfilter. Remove

postfilter from holder and

discard. Disconnect postfilter

tube at tank shutoff valve.

Retain postfilter tube.
Hold a container under tank

shutoff valve. Open shutoff

valve and drain water from

tank. (Expect up to 1/2 gallon.)

Sanitize the system. Go to

Sanitizing the RO System

section

and follow steps 1–8.

9

8

7

6

5

4

3

2

1

6

CLOSED

OPEN

Operating Instructions

Safety Instructions

Care and Cleaning

Troubleshooting T

ips

Consumer Support

Pre/Post Filter Cartridge Replacements FX18P

Activated Carbon

Reverse Osmosis Cartridge Replacement FX18M

Thin Film Polyamide

Содержание PNRV18ZCC01

Страница 1: ...ification Guidelines 3 Care and Cleaning Battery Replacement 10 Check the System 8 Filter Replacement Procedures 6 8 Flow Control and Screen 9 RO Cartridge Replacement 9 Sanitizing the System 7 10 Troubleshooting Tips Before You Call For Service 12 13 Common Problems 14 Consumer Support Consumer Support Back Cover Warranty 15 The GE RO PNRV18Z Model Series is Tested and Certified by NSF Internatio...

Страница 2: ...luent concentrations of no more than 27 mg L nitrate and 3 mg L nitrite in combination measured as N and is certified for nitrate nitrite reduction only for water supplies with a pressure of 280kPa 40 psig or greater SAVE THESE INSTRUCTIONS READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY Install or store where it will not be exposed to temperatures below freezing or exposed to any type of weathe...

Страница 3: ...n sulfide ppm 0 1 Chlorine in water supply Allowable Feed water pH limits pH 4 10 Percent rejection of TDS minimum new membrane 92 Chlorine removed maximum of 2 0 ppm by the Reverse Osmosis prefilter regular changing of the prefilter is required Chlorine will destroy the Reverse Osmosis membrane Feed water at 50 psig and 77 F with 750 ppm sodium chloride Quality water production amount of waste wa...

Страница 4: ...essurized for fast flow to the faucet when drinking water is needed Check Valve A check valve is built into the bottom end of the Reverse Osmosis housing The check valve prevents a backward flow of product water from the storage area A backward flow could cause rupture of the Reverse Osmosis membrane Automatic Shutoff Assembly To conserve water the drinking water system has an automatic shutoff Wh...

Страница 5: ...of the flashing RO light Long periods of limited or non use can cause the TDS levels to temporarily change If the Reverse Osmosis Filtration System Is Connected to Your Icemaker Before you service the filter change the filters or purge the Filtration system YOU MUST turn off the icemaker by raising the feeler arm Four hours after servicing your unit lower the feeler arm to resume icemaking Purging...

Страница 6: ...osis Filtration System is connected to your icemaker YOU MUST turn off the icemaker by raising the feeler arm before servicing the filter changing the filters or purging the filtration system After completing work allow four hours for unit to refill then lower the feeler arm to resume icemaking Pull the Reverse Osmosis system away from cabinet leave tubing connected Place a dry towel under the sys...

Страница 7: ...nnect to electronics box A small amount of water will drain when fitting is disconnected Remove the clamp retainers and sections from top of the unit Lift the Reverse Osmosis cap straight up slight resistance is normal from the Reverse Osmosis housing no need to disconnect tubing and move aside Dispose of water from the Reverse Osmosis housing NOTE If the cap o ring remained in the Reverse Osmosis...

Страница 8: ...x to bottom of postfilter Snap postfilter into holder The flow arrow printed on the side of the filter should be pointed down Replace batteries in battery case with four new AA alkaline batteries Note orientation and of batteries Weak batteries will give no or a false indication Replacing batteries also resets the six month clock and filter light will flash green NOTE Lights may not operate proper...

Страница 9: ...t force in further after you feel resistance Visually check to be sure it is properly positioned Install the flow control and tighten by hand then another 1 4 turn with pliers DO NOT OVERTIGHTEN AND DISTORT OR CRUSH THE TUBING AND FLOW CONTROL If you are replacing the Reverse Osmosis cartridge return to the Reverse Osmosis Cartridge Replacement instructions Otherwise open red tank shutoff valve an...

Страница 10: ...e Osmosis system and after servicing inner parts of the Reverse Osmosis system including replacement of prefilter postfilter and Reverse Osmosis cartridge It is important to wash hands with anti bacterial soap before handling inner parts of the system See the Sanitize the System section for instructions CAUTION If installing unit in New Construction ensure house plumbing is flushed thoroughly befo...

Страница 11: ...11 Consumer Support Operating Instructions Safety Instructions Care and Cleaning Troubleshooting Tips Notes www GEAppliances com ...

Страница 12: ...e Reverse Osmosis Replace the Reverse Osmosis membrane cartridge of this flashing light membrane is no longer flow control and screen removing the required amount of Total Dissolved Solids Water supply to the Reverse Increase water pressure precondition the water etc Osmosis system not within as needed to conform before doing maintenance on specifications the Reverse Osmosis system Incorrect brine...

Страница 13: ...Water leaking from Drain side of faucet air gap Inspect and eliminate restriction or plug It is important faucet air gap hole 3 8 tubing plugged that there are no dips loops or low spots in the drain line restricted or incorrectly from the faucet air gap to the drain pipe Refer to connected to the drain Installation Instructions for proper drain connection If drain line adapter was used as the dra...

Страница 14: ...ges Leak at fittings Use pliers to tighten fittings until leak stops Do not overtighten FILTER light flashes Batteries not changed Replace batteries See step 5 under Replace the Filters yellow When batteries are replaced the light will flash green and the 6 months timer will be reset RO light flashes Prefilter cartridge Remove RO cap and look at end of prefilter cartridge yellow assembled upside d...

Страница 15: ...ights and you may also have other rights which vary from state to state To know what your legal rights are consult your local or state consumer affairs office or your state s Attorney General Warrantor General Electric Company Louisville KY 40225 For The Period Of GE Will Replace One Year Any part of the Reverse Osmosis Filtration System which fails due to a defect in materials or From the date of...

Страница 16: ... about special discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories www GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes V...