background image

8 PMC423 Port Serial, Front/Rear I/O Hardware Reference Manual

Safety Summary

The

 

following

 

general

 

safety

 

precautions

 

must

 

be

 

observed

 

during

 

all

 

phases

 

of

 

the

 

operation,

 

service

 

and

 

repair

 

of

 

this

 

product.

 

Failure

 

to

 

comply

 

with

 

these

 

precautions

 

or

 

with

 

specific

 

warnings

 

elsewhere

 

in

 

this

 

manual

 

violates

 

safety

 

standards

 

of

 

design,

 

manufacture

 

and

 

intended

 

use

 

of

 

this

 

product.

 

GEIP

 

assumes

 

no

 

liability

 

for

 

the

 

customer

ʹ

s

 

failure

 

to

 

comply

 

with

 

these

 

requirements.

Ground the 

System

To

 

minimize

 

shock

 

hazard,

 

the

 

chassis

 

and

 

system

 

cabinet

 

must

 

be

 

connected

 

to

 

an

 

electrical

 

ground.

 

A

 

three

conductor

 

AC

 

power

 

cable

 

should

 

be

 

used.

 

The

 

power

 

cable

 

must

 

either

 

be

 

plugged

 

into

 

an

 

approved

 

three

contact

 

electrical

 

outlet

 

or

 

used

 

with

 

a

 

three

contact

 

to

 

two

contact

 

adapter

 

with

 

the

 

grounding

 

wire

 

(green)

 

firmly

 

connected

 

to

 

an

 

electrical

 

ground

 

(safety

 

ground)

 

at

 

the

 

power

 

outlet.

Do Not Operate in 

an Explosive 

Atmosphere

Do

 

not

 

operate

 

the

 

system

 

in

 

the

 

presence

 

of

 

flammable

 

gases

 

or

 

fumes.

 

Operation

 

of

 

any

 

electrical

 

system

 

in

 

such

 

an

 

environment

 

constitutes

 

a

 

definite

 

safety

 

hazard.

Keep Away from 

Live Circuits

Operating

 

personnel

 

must

 

not

 

remove

 

product

 

covers.

 

Component

 

replacement

 

and

 

internal

 

adjustments

 

must

 

be

 

made

 

by

 

qualified

 

maintenance

 

personnel.

 

Do

 

not

 

replace

 

components

 

with

 

power

 

cable

 

connected.

 

Under

 

certain

 

conditions,

 

dangerous

 

voltages

 

may

 

exist

 

even

 

with

 

the

 

power

 

cable

 

removed.

 

To

 

avoid

 

injuries,

 

always

 

disconnect

 

power

 

and

 

discharge

 

circuits

 

before

 

touching

 

them.

Do Not Service or 

Adjust Alone

Do

 

not

 

attempt

 

internal

 

service

 

or

 

adjustment

 

unless

 

another

 

person

 

capable

 

of

 

rendering

 

first

 

aid

 

and

 

resuscitation

 

is

 

present.

Do Not Substitute 

Parts or Modify 

System

Because

 

of

 

the

 

danger

 

of

 

introducing

 

additional

 

hazards,

 

do

 

not

 

install

 

substitute

 

parts

 

or

 

perform

 

any

 

unauthorized

 

modification

 

to

 

the

 

product.

 

Return

 

the

 

product

 

to

 

GEIP

 

for

 

service

 

and

 

repair

 

to

 

ensure

 

that

 

safety

 

features

 

are

 

maintained.

Dangerous 

Procedure 

Warnings

Warnings,

 

such

 

as

 

the

 

example

 

below,

 

precede

 

only

 

potentially

 

dangerous

 

procedures

 

throughout

 

this

 

manual.

 

Instructions

 

contained

 

in

 

the

 

warnings

 

must

 

be

 

followed.

WARNING

Dangerous voltages, capable of causing death, are present in this system. 

Use extreme caution when handling, testing and adjusting.

Содержание PMC423 Series

Страница 1: ...GE Intelligent Platforms Publication No RX URMH 006 Rev C Hardware Reference PMC423 Port Serial Front Rear I O ...

Страница 2: ...Document History Hardware Reference Manual Document Number RX URMH 006 Rev C July 13 2011 ...

Страница 3: ...w 6 1 Handling and Installation 10 1 1 Handling Precautions 10 1 2 Unpacking Procedures 10 1 3 Installation 11 1 4 Front Panel Connectors and Indicators 12 1 5 I O Signal Pinouts 14 1 5 1 RS485 Support SW2 SW12 15 2 Theory of Operation 17 2 1 PMC423 Block Diagram 17 Maintenance 19 ...

Страница 4: ... I O Hardware Reference Manual List of Figures Figure 1 1 Installation of PMC Module 11 Figure 1 2 Front Panel Connectors and Indicator 12 Figure 1 3 PIM422 13 Figure 1 4 Default Switch Settings 16 Figure 2 1 PMC423 Block Diagram 17 ...

Страница 5: ...List of Tables 5 List of Tables Table 1 1 I O Signal Pinouts PMC423 14 Table 1 2 RS485 Support Switches SW2 SW12 15 ...

Страница 6: ... for enhanced software to improve performance Product Features The PMC423 is a powerful and flexible method to integrate serial data channels to a PCI system Features include Sixteen independent serial channels Programmable baud rate from 100 bits second to 921 6Kbits s with default Crystal at 14 7456 MHz UART register sets compatible with 16C550 64 Byte First in First out FIFO per channel Full PC...

Страница 7: ... Chapter 1 Handling and Installation describes the handling installation front panel I O pin assignments and RS485 support for the PMC423 Chapter 2 Theory of Operation provides information for local device connections the bridge to the host PCI and the general systemʹs function Maintenance provides GE s contact information relative to the care and maintenance of the unit ...

Страница 8: ...n such an environment constitutes a definite safety hazard Keep Away from Live Circuits Operating personnel must not remove product covers Component replacement and internal adjustments must be made by qualified maintenance personnel Do not replace components with power cable connected Under certain conditions dangerous voltages may exist even with the power cable removed To avoid injuries always ...

Страница 9: ...nnel CAUTION CAUTION denotes a hazard It calls attention to an operating procedure practice or condition which if not correctly performed or adhered to could result in damage to or destruction of part or all of the system NOTE NOTE denotes important information It calls attention to a procedure practice or condition which is essential to highlight TIP Tip denotes a bit of expert information LINK T...

Страница 10: ...e board is placed on a bench for configuring etc it is suggested that conductive material be inserted under the board to provide a conductive shunt Unused boards should be stored in the same protective boxes in which they were shipped 1 2 Unpacking Procedures Any precautions found in the shipping container should be observed All items should be carefully unpacked and thoroughly inspected for damag...

Страница 11: ...module into the mating connectors on the host s printed circuit board 5 Make sure the PMC module is seated properly into the common mezzanine card CMC connectors on the host 6 Use screws to fasten PMC to the host CMC 7 Remove the four screws from the bottom of the stand offs of the PMC 8 Line up the J1 and J2 connectors on the host CMC to the J1 and J2 connectors on the PMC 9 Ensure all connectors...

Страница 12: ...rs and Indicators The front panel connector is a high density small computer system interface SCSI female connector AMP part number AMP 796055 1 Figure 1 2 Front Panel Connectors and Indicator LED indicators controlled by the MPIO pins of the UART High Density SCSI connector PMC423 PIM422 ...

Страница 13: ...Handling and Installation 13 Figure 1 3 PIM422 TOP BOTTOM ...

Страница 14: ...d is available on the front panel connector on pins 9 27 43 and 61 Table 1 1 I O Signal Pinouts PMC423 Port Signal Front Panel Pin J4 Pin Port Signal Positive Negative Positive Negative 1 RX 2 1 2 1 TX 4 3 4 3 2 RX 6 5 6 5 TX 8 7 8 7 3 RX 11 10 10 9 TX 13 12 12 11 4 RX 15 14 14 13 TX 17 16 16 15 5 RX 19 18 18 17 TX 21 20 20 19 6 RX 23 22 22 21 TX 25 24 24 23 7 RX 28 26 26 25 TX 30 29 28 27 8 RX 32...

Страница 15: ...m used for details As shipped from factory all switches are in the Open state Where SW3 4 means Switch pack 4 switch 4 etc NOTE NOTE The above applies to the Rev D and later revisions of the board For earlier revisions please e mail support huntsville ip ge com Table 1 2 RS485 Support Switches SW2 SW12 Port 1 SW1 1 SW2 1 SW9 1 2 SW1 2 SW2 2 SW9 2 3 SW1 3 SW2 3 SW9 3 4 SW1 4 SW2 4 SW9 4 5 SW3 1 SW4...

Страница 16: ...16 PMC423 Port Serial Front Rear I O Hardware Reference Manual Figure 1 4 Default Switch Settings ...

Страница 17: ... communication RS232 RS422 etc are configured via the software The card generates the necessary voltage for the serial signaling onboard using the 5V supply This allows the PMC423 to operate from the 3 3V and 5V supply only There are two eight port serial devices that are after the PCI to PCI bridge for a total of sixteen ports Due to the density of the serial ports the hardware handshake signals ...

Страница 18: ...urring all bus protocol overhead for every character transferred and control operations The Octal UART utilized on the PMC423 supports 32 bit transfers allowing four characters to be transferred in a single bus operation Reducing programmed I O operations is critical to achieving good performance in PCI systems While the extended transfer options offer an opportunity to maximize performance in man...

Страница 19: ... board from the chassis 8 Quality of cables and I O connections If products must be returned contact GE for a Return Material Authorization RMA Number This RMA Number must be obtained prior to any return RMA request forms can be obtained from www ge ip com rma GE Technical Support is available at 1 800 433 2682 in North America or 1 780 401 7700 for international calls Requests for Technical Suppo...

Страница 20: ...S CONTENTS ARE PROVIDED AS IS WITH NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTIES OF DESIGN MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ALL OTHER LIABILITY ARISING FROM RELIANCE UPON ANY INFORMATION CONTAINED HEREIN IS EXPRESSLY DISCLAIMED GE Intelligent Platforms Information Centers Americas 1 800 322 3616 or 1 256 880 0444 ...

Отзывы: