6 PMC423 Port Serial, Front/Rear I/O Hardware Reference Manual

Overview

Introduction

The

 

PMC423*

 

is

 

a

 

versatile

 

sixteen

 

port

 

serial

 

controller

 

in

 

PCI

 

Mezzanine

 

Card

 

(PMC)

 

format.

 

Signaling

 

characteristics

 

of

 

each

 

port

 

can

 

be

 

controlled

 

for

 

RS232,

 

RS422

 

or

 

RS485

 

operations.

 

The

 

signaling

 

protocol

 

configuration

 

is

 

per

 

four

 

channels,

 

providing

 

four

 

independent

 

configuration

 

settings.

 

The

 

serial

 

interfaces

 

are

 

implemented

 

using

 

an

 

Octal

 

UART.

 

This

 

combines

 

compatibility

 

with

 

the

 

most

 

commonly

 

used

 

components

 

(16C550

 

compatible

 

register

 

set),

 

with

 

full

 

support

 

of

 

PCI

 

attributes

 

(e.g.,

 

32

bit

 

data

 

transfers)

 

for

 

increased

 

performance.

 

This

 

allows

 

rapid

 

integration

 

to

 

legacy

 

systems,

 

while

 

providing

 

an

 

evolutionary

 

path

 

for

 

enhanced

 

software

 

to

 

improve

 

performance.

Product Features

The

 

PMC423

 

is

 

a

 

powerful

 

and

 

flexible

 

method

 

to

 

integrate

 

serial

 

data

 

channels

 

to

 

a

 

PCI

 

system.

  

Features

 

include:

  

 

Sixteen

 

independent

 

serial

 

channels

 

Programmable

 

baud

 

rate

 

from

 

100

bits/second

 

to

 

921.6Kbits/s

 

(*with

 

default

 

Crystal

 

at

 

14.7456

 

MHz)

 

UART

 

register

 

sets

 

compatible

 

with

 

16C550

 

64

 

Byte

 

First

in/First

out

 

(FIFO)

 

per

 

channel

 

Full

 

PCI

 

compatibility

 

(32

bit/33

 

and

 

66

 

MHz

 

PCI

 

capable)

 

Signaling

 

characteristics

 

of

 

each

 

channel

 

pair

 

(RS232/RS422/RS485)

 

 

configured

 

with

 

software

 

Two

 

Input/Output

 

(I/O)

 

routings:

– Sixteen

 

ports

 

front

 

connection

– Sixteen

 

ports

 

rear

 

(J4)

 

connection

NOTE

Customer may specify the speed of the Crystal. 

Software Support

GE

 

provides

 

full

 

software

 

support

 

for

 

all

 

of

 

the

 

popular

 

software

 

environments

 

(e.g.,

 

VxWorks

®

,

 

LynxOS

®

,

 

Windows

 

NT

®

,

 

Solaris

TM

).

 

Each

 

driver

 

has

 

been

 

developed

 

specifically

 

for

 

the

 

real

time

 

data

 

acquisition

 

market.

Содержание PMC423 Series

Страница 1: ...GE Intelligent Platforms Publication No RX URMH 006 Rev C Hardware Reference PMC423 Port Serial Front Rear I O ...

Страница 2: ...Document History Hardware Reference Manual Document Number RX URMH 006 Rev C July 13 2011 ...

Страница 3: ...w 6 1 Handling and Installation 10 1 1 Handling Precautions 10 1 2 Unpacking Procedures 10 1 3 Installation 11 1 4 Front Panel Connectors and Indicators 12 1 5 I O Signal Pinouts 14 1 5 1 RS485 Support SW2 SW12 15 2 Theory of Operation 17 2 1 PMC423 Block Diagram 17 Maintenance 19 ...

Страница 4: ... I O Hardware Reference Manual List of Figures Figure 1 1 Installation of PMC Module 11 Figure 1 2 Front Panel Connectors and Indicator 12 Figure 1 3 PIM422 13 Figure 1 4 Default Switch Settings 16 Figure 2 1 PMC423 Block Diagram 17 ...

Страница 5: ...List of Tables 5 List of Tables Table 1 1 I O Signal Pinouts PMC423 14 Table 1 2 RS485 Support Switches SW2 SW12 15 ...

Страница 6: ... for enhanced software to improve performance Product Features The PMC423 is a powerful and flexible method to integrate serial data channels to a PCI system Features include Sixteen independent serial channels Programmable baud rate from 100 bits second to 921 6Kbits s with default Crystal at 14 7456 MHz UART register sets compatible with 16C550 64 Byte First in First out FIFO per channel Full PC...

Страница 7: ... Chapter 1 Handling and Installation describes the handling installation front panel I O pin assignments and RS485 support for the PMC423 Chapter 2 Theory of Operation provides information for local device connections the bridge to the host PCI and the general systemʹs function Maintenance provides GE s contact information relative to the care and maintenance of the unit ...

Страница 8: ...n such an environment constitutes a definite safety hazard Keep Away from Live Circuits Operating personnel must not remove product covers Component replacement and internal adjustments must be made by qualified maintenance personnel Do not replace components with power cable connected Under certain conditions dangerous voltages may exist even with the power cable removed To avoid injuries always ...

Страница 9: ...nnel CAUTION CAUTION denotes a hazard It calls attention to an operating procedure practice or condition which if not correctly performed or adhered to could result in damage to or destruction of part or all of the system NOTE NOTE denotes important information It calls attention to a procedure practice or condition which is essential to highlight TIP Tip denotes a bit of expert information LINK T...

Страница 10: ...e board is placed on a bench for configuring etc it is suggested that conductive material be inserted under the board to provide a conductive shunt Unused boards should be stored in the same protective boxes in which they were shipped 1 2 Unpacking Procedures Any precautions found in the shipping container should be observed All items should be carefully unpacked and thoroughly inspected for damag...

Страница 11: ...module into the mating connectors on the host s printed circuit board 5 Make sure the PMC module is seated properly into the common mezzanine card CMC connectors on the host 6 Use screws to fasten PMC to the host CMC 7 Remove the four screws from the bottom of the stand offs of the PMC 8 Line up the J1 and J2 connectors on the host CMC to the J1 and J2 connectors on the PMC 9 Ensure all connectors...

Страница 12: ...rs and Indicators The front panel connector is a high density small computer system interface SCSI female connector AMP part number AMP 796055 1 Figure 1 2 Front Panel Connectors and Indicator LED indicators controlled by the MPIO pins of the UART High Density SCSI connector PMC423 PIM422 ...

Страница 13: ...Handling and Installation 13 Figure 1 3 PIM422 TOP BOTTOM ...

Страница 14: ...d is available on the front panel connector on pins 9 27 43 and 61 Table 1 1 I O Signal Pinouts PMC423 Port Signal Front Panel Pin J4 Pin Port Signal Positive Negative Positive Negative 1 RX 2 1 2 1 TX 4 3 4 3 2 RX 6 5 6 5 TX 8 7 8 7 3 RX 11 10 10 9 TX 13 12 12 11 4 RX 15 14 14 13 TX 17 16 16 15 5 RX 19 18 18 17 TX 21 20 20 19 6 RX 23 22 22 21 TX 25 24 24 23 7 RX 28 26 26 25 TX 30 29 28 27 8 RX 32...

Страница 15: ...m used for details As shipped from factory all switches are in the Open state Where SW3 4 means Switch pack 4 switch 4 etc NOTE NOTE The above applies to the Rev D and later revisions of the board For earlier revisions please e mail support huntsville ip ge com Table 1 2 RS485 Support Switches SW2 SW12 Port 1 SW1 1 SW2 1 SW9 1 2 SW1 2 SW2 2 SW9 2 3 SW1 3 SW2 3 SW9 3 4 SW1 4 SW2 4 SW9 4 5 SW3 1 SW4...

Страница 16: ...16 PMC423 Port Serial Front Rear I O Hardware Reference Manual Figure 1 4 Default Switch Settings ...

Страница 17: ... communication RS232 RS422 etc are configured via the software The card generates the necessary voltage for the serial signaling onboard using the 5V supply This allows the PMC423 to operate from the 3 3V and 5V supply only There are two eight port serial devices that are after the PCI to PCI bridge for a total of sixteen ports Due to the density of the serial ports the hardware handshake signals ...

Страница 18: ...urring all bus protocol overhead for every character transferred and control operations The Octal UART utilized on the PMC423 supports 32 bit transfers allowing four characters to be transferred in a single bus operation Reducing programmed I O operations is critical to achieving good performance in PCI systems While the extended transfer options offer an opportunity to maximize performance in man...

Страница 19: ... board from the chassis 8 Quality of cables and I O connections If products must be returned contact GE for a Return Material Authorization RMA Number This RMA Number must be obtained prior to any return RMA request forms can be obtained from www ge ip com rma GE Technical Support is available at 1 800 433 2682 in North America or 1 780 401 7700 for international calls Requests for Technical Suppo...

Страница 20: ...S CONTENTS ARE PROVIDED AS IS WITH NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTIES OF DESIGN MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ALL OTHER LIABILITY ARISING FROM RELIANCE UPON ANY INFORMATION CONTAINED HEREIN IS EXPRESSLY DISCLAIMED GE Intelligent Platforms Information Centers Americas 1 800 322 3616 or 1 256 880 0444 ...

Отзывы: