background image

10  PMC423 Port Serial, Front/Rear I/O Hardware Reference Manual

1 • Handling and Installation

1.1 Handling Precautions

CAUTION

Handle the board by the edges or front panel only.

Electronic

 

assemblies

 

use

 

devices

 

that

 

are

 

sensitive

 

to

 

static

 

discharge.

 

Some

 

of

 

the

 

components

 

assembled

 

on

 

GE

 

products

 

may

 

be

 

sensitive

 

to

 

electrostatic

 

discharge

 

and

 

damage

 

may

 

occur

 

on

 

boards

 

that

 

are

 

subjected

 

to

 

a

 

high

 

energy

 

electrostatic

 

field.

 

Observe

 

anti

static

 

procedures

 

when

 

handling

 

these

 

boards.

  

All

 

products

 

should

 

be

 

in

 

an

 

anti

static

 

plastic

 

bag

 

or

 

conductive

 

foam

 

for

 

storage

 

or

 

shipment.

 

Work

 

at

 

an

 

approved

 

anti

static

 

workstation

 

when

 

unpacking

 

boards.

 

When

 

the

 

board

 

is

 

placed

 

on

 

a

 

bench

 

for

 

configuring,

 

etc.,

 

it

 

is

 

suggested

 

that

 

conductive

 

material

 

be

 

inserted

 

under

 

the

 

board

 

to

 

provide

 

a

 

conductive

 

shunt.Unused

 

boards

 

should

 

be

 

stored

 

in

 

the

 

same

 

protective

 

boxes

 

in

 

which

 

they

 

were

 

shipped.

1.2 Unpacking Procedures 

Any

 

precautions

 

found

 

in

 

the

 

shipping

 

container

 

should

 

be

 

observed.

 

All

 

items

 

should

 

be

 

carefully

 

unpacked

 

and

 

thoroughly

 

inspected

 

for

 

damage

 

that

 

might

 

have

 

occurred

 

during

 

shipment.

 

The

 

board(s)

 

should

 

be

 

checked

 

for

 

broken

 

components,

 

damaged

 

printed

 

circuit

 

board(s),

 

heat

 

damage

 

and

 

other

 

visible

 

contamination.

 

All

 

claims

 

arising

 

from

 

shipping

 

damage

 

should

 

be

 

filed

 

with

 

the

 

carrier

 

and

 

a

 

complete

 

report

 

sent

 

to

 

GE

 

Technical

 

Support.

 

Remove

 

the

 

PMC423

 

from

 

the

 

shipping

 

box

 

and

 

anti

static

 

packaging.

  

Verify

 

that

 

it

 

is

 

not

 

damaged

 

and

 

that

 

all

 

items

 

are

 

present

 

by

 

referring

 

to

 

the

 

packing

 

list.

Содержание PMC423 Series

Страница 1: ...GE Intelligent Platforms Publication No RX URMH 006 Rev C Hardware Reference PMC423 Port Serial Front Rear I O ...

Страница 2: ...Document History Hardware Reference Manual Document Number RX URMH 006 Rev C July 13 2011 ...

Страница 3: ...w 6 1 Handling and Installation 10 1 1 Handling Precautions 10 1 2 Unpacking Procedures 10 1 3 Installation 11 1 4 Front Panel Connectors and Indicators 12 1 5 I O Signal Pinouts 14 1 5 1 RS485 Support SW2 SW12 15 2 Theory of Operation 17 2 1 PMC423 Block Diagram 17 Maintenance 19 ...

Страница 4: ... I O Hardware Reference Manual List of Figures Figure 1 1 Installation of PMC Module 11 Figure 1 2 Front Panel Connectors and Indicator 12 Figure 1 3 PIM422 13 Figure 1 4 Default Switch Settings 16 Figure 2 1 PMC423 Block Diagram 17 ...

Страница 5: ...List of Tables 5 List of Tables Table 1 1 I O Signal Pinouts PMC423 14 Table 1 2 RS485 Support Switches SW2 SW12 15 ...

Страница 6: ... for enhanced software to improve performance Product Features The PMC423 is a powerful and flexible method to integrate serial data channels to a PCI system Features include Sixteen independent serial channels Programmable baud rate from 100 bits second to 921 6Kbits s with default Crystal at 14 7456 MHz UART register sets compatible with 16C550 64 Byte First in First out FIFO per channel Full PC...

Страница 7: ... Chapter 1 Handling and Installation describes the handling installation front panel I O pin assignments and RS485 support for the PMC423 Chapter 2 Theory of Operation provides information for local device connections the bridge to the host PCI and the general systemʹs function Maintenance provides GE s contact information relative to the care and maintenance of the unit ...

Страница 8: ...n such an environment constitutes a definite safety hazard Keep Away from Live Circuits Operating personnel must not remove product covers Component replacement and internal adjustments must be made by qualified maintenance personnel Do not replace components with power cable connected Under certain conditions dangerous voltages may exist even with the power cable removed To avoid injuries always ...

Страница 9: ...nnel CAUTION CAUTION denotes a hazard It calls attention to an operating procedure practice or condition which if not correctly performed or adhered to could result in damage to or destruction of part or all of the system NOTE NOTE denotes important information It calls attention to a procedure practice or condition which is essential to highlight TIP Tip denotes a bit of expert information LINK T...

Страница 10: ...e board is placed on a bench for configuring etc it is suggested that conductive material be inserted under the board to provide a conductive shunt Unused boards should be stored in the same protective boxes in which they were shipped 1 2 Unpacking Procedures Any precautions found in the shipping container should be observed All items should be carefully unpacked and thoroughly inspected for damag...

Страница 11: ...module into the mating connectors on the host s printed circuit board 5 Make sure the PMC module is seated properly into the common mezzanine card CMC connectors on the host 6 Use screws to fasten PMC to the host CMC 7 Remove the four screws from the bottom of the stand offs of the PMC 8 Line up the J1 and J2 connectors on the host CMC to the J1 and J2 connectors on the PMC 9 Ensure all connectors...

Страница 12: ...rs and Indicators The front panel connector is a high density small computer system interface SCSI female connector AMP part number AMP 796055 1 Figure 1 2 Front Panel Connectors and Indicator LED indicators controlled by the MPIO pins of the UART High Density SCSI connector PMC423 PIM422 ...

Страница 13: ...Handling and Installation 13 Figure 1 3 PIM422 TOP BOTTOM ...

Страница 14: ...d is available on the front panel connector on pins 9 27 43 and 61 Table 1 1 I O Signal Pinouts PMC423 Port Signal Front Panel Pin J4 Pin Port Signal Positive Negative Positive Negative 1 RX 2 1 2 1 TX 4 3 4 3 2 RX 6 5 6 5 TX 8 7 8 7 3 RX 11 10 10 9 TX 13 12 12 11 4 RX 15 14 14 13 TX 17 16 16 15 5 RX 19 18 18 17 TX 21 20 20 19 6 RX 23 22 22 21 TX 25 24 24 23 7 RX 28 26 26 25 TX 30 29 28 27 8 RX 32...

Страница 15: ...m used for details As shipped from factory all switches are in the Open state Where SW3 4 means Switch pack 4 switch 4 etc NOTE NOTE The above applies to the Rev D and later revisions of the board For earlier revisions please e mail support huntsville ip ge com Table 1 2 RS485 Support Switches SW2 SW12 Port 1 SW1 1 SW2 1 SW9 1 2 SW1 2 SW2 2 SW9 2 3 SW1 3 SW2 3 SW9 3 4 SW1 4 SW2 4 SW9 4 5 SW3 1 SW4...

Страница 16: ...16 PMC423 Port Serial Front Rear I O Hardware Reference Manual Figure 1 4 Default Switch Settings ...

Страница 17: ... communication RS232 RS422 etc are configured via the software The card generates the necessary voltage for the serial signaling onboard using the 5V supply This allows the PMC423 to operate from the 3 3V and 5V supply only There are two eight port serial devices that are after the PCI to PCI bridge for a total of sixteen ports Due to the density of the serial ports the hardware handshake signals ...

Страница 18: ...urring all bus protocol overhead for every character transferred and control operations The Octal UART utilized on the PMC423 supports 32 bit transfers allowing four characters to be transferred in a single bus operation Reducing programmed I O operations is critical to achieving good performance in PCI systems While the extended transfer options offer an opportunity to maximize performance in man...

Страница 19: ... board from the chassis 8 Quality of cables and I O connections If products must be returned contact GE for a Return Material Authorization RMA Number This RMA Number must be obtained prior to any return RMA request forms can be obtained from www ge ip com rma GE Technical Support is available at 1 800 433 2682 in North America or 1 780 401 7700 for international calls Requests for Technical Suppo...

Страница 20: ...S CONTENTS ARE PROVIDED AS IS WITH NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTIES OF DESIGN MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ALL OTHER LIABILITY ARISING FROM RELIANCE UPON ANY INFORMATION CONTAINED HEREIN IS EXPRESSLY DISCLAIMED GE Intelligent Platforms Information Centers Americas 1 800 322 3616 or 1 256 880 0444 ...

Отзывы: