![GE NX-4-EUR Скачать руководство пользователя страница 88](http://html.mh-extra.com/html/ge/nx-4-eur/nx-4-eur_installation-manual_123030088.webp)
A
PPENDIX
1: R
EPORTING FIXED CODES IN
C
ONTACT
-ID
AND
SIA
The table below lists the event codes sent for the following reports (if enabled) when using CONTACT ID or SIA formats.
REPORT
CONTACT ID
SIA
MANUAL TEST
601 RX
AUTOTEST
602 RP
OPEN (User Number)
401 OP
CLOSE (User Number)
401 CL
CANCEL (User Number)
406 OC
DOWNLOAD COMPLETE
412 RS
START PROGRAM
627 LB
END PROGRAM
628 LX
RECENT CLOSE (User Number)
401 CR
EXIT ERROR (User Number)
457 EE
EVENT LOG FULL
605 JL
FAIL TO COMMUNICATE
354 RT
EXPANDER TROUBLE (device number)
333
ET
EXPANDER RESTORE (device number)
333
ER
TELEPHONE FAULT
351 LT
TELEPHONE RESTORE
351 LR
SIREN TAMPER
321 YA
SIREN RESTORE
321 YH
AUX POWER OVERCURRENT (device number)
312
YP
AUX POWER RESTORE (device number)
312
YQ
LOW BATTERY (device number)
309 YT
LOW BATTERY RESTORE (device number)
309
YR
AC FAIL (device number)
301 AT
AC RESTORE (device number)
301 AR
BOX TAMPER (device number)
137 TA
BOX TAMPER RESTORE (device number)
137
TR
KEYPAD TAMPER
137 TA
KEYPAD PANIC (audible)
120 PA
KEYPAD PANIC (silent)
121 HA
DURESS
121 HA
KEYPAD AUXILIARY 1
110 FA
KEYPAD AUXILIARY 2
100 MA
RF SENSOR LOST (zone number)
381
*T
RF SENSOR RESTORE (zone number)
381
*R
SENSOR LOW BATTERY (zone number)
384
XT
SENSOR BATTERY RESTORE (zone number)
384
XR
ZONE TROUBLE (zone number)
380 *T
ZONE TROUBLE RESTORE (zone number)
380
*R
ZONE TAMPER (zone number)
137 TA
ZONE TAMPER RESTORE (zone number)
137
TR
ZONE BYPASS (zone number)
570 *B
BYPASS RESTORE (zone number)
570
*U
EARLY OPEN / LATE CLOSE
451 OK
FAIL TO CLOSE
454 CI
ZONE ACTIVITY FAULT
391 NA
ZONE ACTIVITY RESTORE
391 NS
FREEZE ALARM
159 ZA
HEAT ALARM RESTORE
158 KH
MANUAL FIRE ALARM (pull station)
115
FA
THE NUMBER IN PARENTHESES FOLLOWING THE EVENT IS THE NUMBER THAT WILL BE REPORTED AS THE ZONE NUMBER. IF THERE ARE NO
PARENTHESES, THE ZONE WILL BE “0”. SEE APPENDIX 3 FOR THE DEVICE NUMBERS.
* The character transmitted in this slot will be the first character from the event code of the zone that is bypassed or in trouble (see locations
110 - 169).
NX-4-EUR Installation manual
Page 88
02/07/06
Содержание NX-4-EUR
Страница 1: ...GE Security NetworX TM Series NX 4 EUR Control Panel Installation manual g imagination at work ...
Страница 2: ...NX 4 EUR Installation manual Page 2 02 07 06 ...
Страница 92: ...CE DECLARATION NX 4 EUR Installation manual Page 92 02 07 06 ...
Страница 93: ...NX 4 EUR Installation manual Page 93 02 07 06 ...
Страница 94: ...NX 4 EUR Installation manual Page 94 02 07 06 ...
Страница 95: ...NX 4 EUR Installation manual Page 95 02 07 06 ...
Страница 96: ...NX 4 EUR Installation manual Page 96 02 07 06 ...
Страница 97: ...NX 4 EUR Installation manual Page 97 02 07 06 ...
Страница 98: ...NX 4 EUR Installation manual Page 98 02 07 06 ...
Страница 99: ...NX 4 EUR Installation manual Page 99 02 07 06 ...