PROGRAMMING EXAMPLE (Feature selection data)
Location 23, segment 1
1 = Quick arm
2 = Re-exit
3 = Auto bypass
4 = Silent keypad panic
5 = Audible keypad panic
6 = Keypad auxiliary 1
7 = Keypad auxiliary 2
8 = Multi-keypad tamper
Press the key on the num
eric keypad that corresponds to the feature you wish to
enable/disable. When a LED is “ON”, a feature is enabled, when “OFF” the feature is disabled.
For example, with the 1, 5 & 7 LED’s “ON”, quick arm, audible keypad panic and keypad
auxiliary 2 are enabled.