![GE NX-4-EUR Скачать руководство пользователя страница 49](http://html.mh-extra.com/html/ge/nx-4-eur/nx-4-eur_installation-manual_123030049.webp)
LOCATION 25 - ZONES 1-8 CONFIGURATION GROUP (8 segments, numerical data)
Location 25 contains the configuration group (zone type) for zones 1-8. Segment 1 is for zone
1, and segment 8 is for zone 8. You will find the default configurations in the table above.
LOCATION 26-36 - RESERVED
General options
LOCATION 37 - SIREN AND SYSTEM SUPERVISION (7 segments, feature selection data)
Location 37 is used to enable various system feature and reporting options.
Segment 1
1 = On: if siren sounds for “Telephone Line Cut” when armed
2 = On: if siren sounds for “Telephone Line Cut” when disarmed
3 = On: if siren blast at arming (pulse)
4 = On: if siren blast at exit expiration (pulse)
5 = On: if siren blast at closing kiss-off (pulse)
6 = On: if siren sounds during a “Cross Zone” verification time
7 = On: if siren sounds for a zone or box tamper
8 = On: if siren blasts 1 time for keyswitch or wireless arming; 2 times for
disarming
Segment 2
1 = On: if siren driver should be a voltage output. Off: if on-board siren
driver is enabled
2 = On: if sirens sound for expander trouble
3 = On: for zones to restore immediately. Off: for zones to restore only
when the siren is off or disarmed
4 = On: if dynamic battery test is performed at arming. Off: if dynamic
battery test is performed at disarming (See location 40)
5 = On: if battery missing test is performed every 12 seconds
6 = On: if manual bell test is performed during [*]-[4]-[4] test function
7 = On: if manual communicator test is performed during [*]-[4]-[4] test
function
8 = On: if Box Tamper terminals on the control panel are enabled
Segment 3
1 = On: if box tamper report is enabled
2 = On: if AC fail reporting is enabled
3 = On: if low battery reporting is enabled
4 = On: if Aux. power overcurrent report is enabled
5 = On: if siren supervision report is enabled
6 = On: if restore telephone line cut report is enabled
7 = On: A+B Alarm. Off: cross-zoning
8 = On: if expander trouble reporting is enabled
Segment 4
1 = On: if fail to communicate report is enabled
2 = On: if log full report is enabled
3 = On: if autotest report is enabled
4 = On: if start/end programming report is enabled
5 = On: if end download report is enabled
6 = On: if sensor low battery report is enabled
7 = On: if sensor missing report is enabled
NX-4-EUR Installation manual
Page 49
02/07/06
Содержание NX-4-EUR
Страница 1: ...GE Security NetworX TM Series NX 4 EUR Control Panel Installation manual g imagination at work ...
Страница 2: ...NX 4 EUR Installation manual Page 2 02 07 06 ...
Страница 92: ...CE DECLARATION NX 4 EUR Installation manual Page 92 02 07 06 ...
Страница 93: ...NX 4 EUR Installation manual Page 93 02 07 06 ...
Страница 94: ...NX 4 EUR Installation manual Page 94 02 07 06 ...
Страница 95: ...NX 4 EUR Installation manual Page 95 02 07 06 ...
Страница 96: ...NX 4 EUR Installation manual Page 96 02 07 06 ...
Страница 97: ...NX 4 EUR Installation manual Page 97 02 07 06 ...
Страница 98: ...NX 4 EUR Installation manual Page 98 02 07 06 ...
Страница 99: ...NX 4 EUR Installation manual Page 99 02 07 06 ...