NX-4-EUR Control Panel 

  

 

Installation manual 

imagination at work 

Содержание NX-4-EUR

Страница 1: ...GE Security NetworX TM Series NX 4 EUR Control Panel Installation manual g imagination at work ...

Страница 2: ...NX 4 EUR Installation manual Page 2 02 07 06 ...

Страница 3: ...THE MODULE TO PROGRAM 30 PROGRAMMING A LOCATION 30 EXITING THE PROGRAM MODE 32 LOADING FACTORY DEFAULTS 32 ENROLLING MODULES AND KEYPADS 32 IMPORTANT REMARKS 33 TAMPER MEMORIZATION 33 DISABLING TAMPER ALARMS IN PROGRAM MODE 33 COUNTRY CODE 33 KEYPAD TAMPER LOCKOUT 33 CLC TS 50131 3 COMPLIANCY 34 CONTROL PANEL PROGRAMMING LOCATIONS 35 TELEPHONE NUMBER 1 35 FORMAT SELECTIONS 36 REPORTING EVENTS TO P...

Страница 4: ...6 TECHNICAL SPECIFICATIONS NX 108 NX 116 NX 124 86 TECHNICAL SPECIFICATIONS NX 1308 NX 1316 NX 1324 87 TECHNICAL SPECIFICATIONS NX 148 87 APPENDIX 1 REPORTING FIXED CODES IN CONTACT ID AND SIA 88 APPENDIX 2 REPORTING ZONE CODES IN SIA OR CONTACT ID 89 APPENDIX 3 EXPANDER NUMBERS FOR REPORTING EXPANDER TROUBLE 91 KEYPADS 91 WIRELESS RECEIVER NX 448E 91 OUTPUT MODULE NX 507E OR NX 508E 91 CE DECLARA...

Страница 5: ...ess audio verification and input output modules all reported with SIA and Contact ID formats which are extremely fast and very comprehensive Thanks to the NetworX design a fully loaded system can be housed in one single metal enclosure establishing for the first time a logical solution and design response to modular systems Two modules can be added to expand the capabilities of the NX 4 ORDERING I...

Страница 6: ...digit code This code can then be used to enter the new arm disarm codes see location 41 Automatic arming If programmed the NX 4 will Auto Arm at a specified time At this time the keypad will start beeping before the panel arms and this for the amount of time set as warning time warning timer The arming process will be stopped during the warning time if a code is entered on the keypad or when movem...

Страница 7: ...y closed tamper switch see wiring diagram The box tamper can be programmed to report and or sound the siren and or the keypad These terminals can be enabled or disabled by programming see locations 37 segment 2 and 3 and location 39 Built In siren driver The NX 4 has a built in 112 dB siren driver If desired this built in driver can easily be converted to a 1 amp voltage output by programming see ...

Страница 8: ...r more trips within a specified time on one or more zones that are programmed as cross zones before it will report an alarm During the time between trips the NX 4 can be programmed to sound the keypad and or the siren The NX 4 can also be programmed to report an alarm after two or more trips on the same zone The first trip on a cross zone is also logged see locations 37 segment 1 39 40 and 110 169...

Страница 9: ...nel is not disarmed before the entry delay expires The alarm report will also be sent If both features Exit Error Report and Exit Error Delay 1 are not enabled the siren will sound if any entry exit zone is faulted as soon as the exit delay expires If the option Exit Error Delay 1 is enabled the siren will sound if only an entry exit 1 zone is faulted see location 23 segment 3 and location 37 segm...

Страница 10: ...by downloading All reportable events are reported to the log Keypad activated panics The NX 4 has three keypad activated panics that will send reports to the central station auxiliary 1 Fire auxiliary 2 Medical and keypad panic Auxiliary 1 will activate the steady Fire siren auxiliary 2 will sound the keypad and the keypad panic can be programmed to be silent or audible see location 23 segment 1 K...

Страница 11: ...ies to NX 1208E NX 1248E keypads In this mode the control panel will bypass all zones that have the Entry Guard feature enabled See location 23 and 111 169 On board zone disable The 4 zones on the NX 4 panel can be disabled in order to obtain a completely wireless alarm system A mix of hardwired and wireless zones is also possible see location 37 segment 5 Program code The factory default for the ...

Страница 12: ...ee location 37 segment 2 and location 38 Telephone line monitor The NX 4 has a telephone line monitor which monitors the voltage and current of the telephone line in order to detect a faulty phone line This condition can also be reported to the central station If the report is enabled only the telephone line restore will be reported A telephone line cut is always logged see locations 37 segment 3 ...

Страница 13: ... armed see location 23 segment 2 Zone Doubling This feature allows you to use the four zones on the panel as eight normally closed zones When this feature is used European double E O L configuration cannot be used THIS FEATURE DOES NOT INCREASE THE TOTAL NUMBER OF AVAILABLE ZONES BEYOND 8 If one of the eight zones must be a fire zone it must be one of Zones 1 to 4 The corresponding upper zone will...

Страница 14: ...ired functions press LED Keypad feature enabled 1 Box tamper on 2 Enable silent keypad option no entry exit delay sounder no chime 3 Enable Ding Dong sound for chime If this is off the chime will be a single tone see location 40 4 Enable keypress silence option Silences the pulsing keypad sounder for 5 seconds when a key is pressed 5 Enable armed status suppression Will not allow the keypad to dis...

Страница 15: ...de day of week 1 Sun month 10 s digit month 1 s digit day 10 s digit 3 day 1 s digit year 10 s digit year 1 s digit 9 7 SET SYSTEM CLOCK 1 Enter 9 7 the Service LED will flash 2 Enter master code hour 10 s digit hour 1 s digit minutes 10 s digit minutes 1 s digit Note the clock is a 24 hour clock 9 8 INITIATE CALLBACK Pressing 9 8 while the system is disarmed will cause the control panel to perfor...

Страница 16: ...nly after closing window 3 Activate output 3 4 Master arm disarm can program other codes 4 Activate output 4 5 Arm disarm code 5 Arm disarm code 6 Allowed to bypass zones see location 23 6 Allowed to bypass zones see location 23 7 Code will send open close reports 7 Code will send open close reports 8 If this LED is on LED s 1 7 will use the chart too the right 8 If this LED is off LED s 1 7 will ...

Страница 17: ...ATION 43 IF YOU WANT TO LET THE END USER ADD NEW CODES YOU MUST REMOVE THE PARTITION AUTHORITY FROM ALL BLANK CODES CHIME ACTIVATING WALKTEST 1 Enter CHIME 2 Enter Master code 3 Activate all sensors to test Each activation of a sensor is confirmed with a ding dong sound with a corresponding flashing zone indicator 4 Enter Master code Herewith the walktest mode is left Remark Walktest mode is not p...

Страница 18: ...hting Use the scroll keys again to set the desired brightness When completed exit by pressing 9 2 PROGRAMMING CUSTOM MESSAGES IN THE KEYPAD 1 Enter 9 2 The LCD screen will prompt for the Go To Program code 2 Enter program code The LCD will now prompt you to enter the message number followed by Zones 1 through 16 custom messages are message numbers 1 16 respectively Message 193 Custom message top l...

Страница 19: ...a single tone 4 5 SEC SILENCE Enable keypress silence option Silences the pulsing keypad sounder for 5 seconds when a key is pressed 5 ARMED ZONE INFO Enable armed status suppression If this is on the keypad will not display faulted or bypassed zones when the system is armed 6 BEEP ON PANICS Enable panic fire medical beep tone Will sound a short beep to verify that the keypress has been accepted 7...

Страница 20: ...rogramming user codes Option 4 ON suppresses beeps when an RF transmission is lost Option 5 Reserved Do not program Option 6 Option 7 Disable ARM and BYPASS led for Norway Sweden NX 148E v3 47 Any zone Alarm has priority over the Pre Alarm message Type code to disarm on the LCD screen NX 148E v3 49 Option 8 Reserved Do not program 9 4 SET KEYPAD NUMBER AND PARTITION 1 Enter 9 4 The LCD screen will...

Страница 21: ...option ex Log Review 90 you can immediately select the wanted option by pressing the 9 0 keys By doing this you don t have to browse through the user s menu In the following table you will find all functions that can be executed by the user USER S MENU Option Description English 1 Description English 2 Zone Review Zone Review 0 Set Tone Set Tone 1 Master Mode Master Mode 2 Service Check Service Ch...

Страница 22: ...the central monitoring station 9 5 SET INCREMENTS HOURS DAYS ELAPSED SINCE LAST AUTOTEST 1 Enter 9 5 The LCD screen will prompt for a code 2 Enter program code The LCD will now display the elapsed time screen 3 Enter 100 s digit 10 s digit 1 s digit 9 7 SET SYSTEM TIME AND DATE 1 Enter 9 7 The LCD screen will prompt for a code 2 Enter master code The date and time will be displayed with the curren...

Страница 23: ...y from one language to another and the other way around Step 1 Press 4 9 The LCD display switches to the other language Step 2 To switch back to the other language only step 1 has to be repeated 5 CHANGING USER CODES Note For partitioned systems someone changing the code of another person must have access to all partitions or to more partitions than the user being changed 1 Enter 5 The LCD screen ...

Страница 24: ...w Master code Output 4 enable Sched arm only Output 3 enable Arm only Output 2 enable Reserved Output 1 enable 4 Enter a partition number The LCD screen will prompt you for the next user code Note The default allows access to all partitions The first keypress will remove access to the partition To re establish access press the partition number again When completed press 5 If another user code need...

Страница 25: ...h a ding dong sound The zone texts of the sensors who have reacted are displayed one by one on the screen 4 Enter mastercode The walktest mode is left Remark 1 All activations and restore conditions occurred during the walk test can be verified by consulting the memory file see function 9 0 2 A walk test mode is not possible if any partition is armed or if the communicator is active NX 4 EUR Insta...

Страница 26: ...ED will light up and the binary data for the first segment of this location will be shown by the zone LED s While entering new data the Ready LED will begin flashing to indicate that a data change is in process The flashing will continue until the new data are stored by pressing the key When you press the key the keypad will advance to the next segment and will display its data Repeat this procedu...

Страница 27: ...e the data has been programmed press the key to enter the data and advance to the next segment of that location After the last segment of a location has been programmed press the key to exit from that location this turns the Ready LED off and the Armed LED on As before you are now ready to enter another programming location If you try to program a number that is too large for a particular segment ...

Страница 28: ...l as described above If necessary go on to program the rest of the control panel and the devices When you exit from program mode the control panel will automatically enroll the devices The enrolling process takes about 12 seconds during which time the Service LED will light up If a module has been enrolled but it is not detected by the control the Service LED will light up PROGRAMMING EXAMPLE Nume...

Страница 29: ...ary 1 7 Keypad auxiliary 2 8 Multi keypad tamper Press the key on the numeric keypad that corresponds to the feature you wish to enable disable When a LED is ON a feature is enabled when OFF the feature is disabled For example with the 1 5 7 LED s ON quick arm audible keypad panic and keypad auxiliary 2 are enabled NX 4 EUR Installation manual Page 29 02 07 06 ...

Страница 30: ...he right The data will be displayed on the bottom line The hex equivalent will be shown in parenthesis To change the data in the current location enter the number followed by The data will be entered and the segment will be incremented by 1 The data for this segment will now be displayed Continue this process until the last segment is programmed When you reach the last segment the keypad will prom...

Страница 31: ...tely select a character from the underlying table By doing this you can quickly form a word without having to scroll down all characters in the list Follow the procedure below to select a character Step 1 Enter the double figured number of the wanted character of the table below Step 2 Confirm the character by pressing the key Step 3 Repeat steps 1 and 2 until the complete word is formed Step 4 Co...

Страница 32: ...hat the locations will be for the module selected Note the timeout for the program mode is 15 minutes LOADING FACTORY DEFAULTS To load the factory defaults enter the program mode using the above procedure then type 9 1 0 The keypad will beep 3 times to show that loading is in progress The loading takes about 6 seconds ENROLLING MODULES AND KEYPADS For supervision purposes the presence of all keypa...

Страница 33: ...mper alarms Note that the timeout for the program mode is 15 minutes Country code The NX 4 has the ability to set different country codes Each country code has specific default settings Before start programming the NX 4 it is important to select the country code that is required Once the country code has been selected it will remain set even after an installer reset When changing the country code ...

Страница 34: ...de location 37 segment 6 option 5 6 digit user codes location 41 option 1 keypad shutdown mode location 41 option 5 A warning device should be protected by a tamper loop Programmable outputs that are used for warning devices must operate for a minimum of 90 seconds and a maximum of 15 minutes unless other requirements are demanded by local or national regulations swinger shutdown counter loc 38 sh...

Страница 35: ...e account code so program a 10 in the segment immediately after the last digit of the account code If the account code is 6 digits long program all 6 segments LOCATION 2 COMMUNICATOR FORMAT FOR PHONE N 1 1 segment numerical data Location 2 contains the communicator format used to transmit to the receiver that is connected to phone N 1 Consult the instructions for your central station receiver to d...

Страница 36: ...rved 9 Radionics extended fast with parity Extended event code 1800hz transmit 2300hz handshake single round w parity 40 PPS extended hex capability 10 Reserved 11 Ademco Silent Knight Slow 1900hz transmit 1400hz handshake 10 PPS double round parity 12 Silent Knight 4 2 fast Two digit event code 1900hz transmit 1400hz handshake 20 PPS double round parity 13 Sescoa Franklin Fast 1800hz transmit 230...

Страница 37: ...artition you should program location 4 as a 0 and use location 5 to select those partitions that are to be reported to phone N 1 If no events are to be reported to phone N 1 both locations should be programmed as 0 LOCATION 4 EVENTS REPORTED TO PHONE N 1 2 segments feature selection data Segment 1 1 Alarms 2 Opening and closings 3 Zone bypass and bypass restores 4 Zone trouble and trouble restores...

Страница 38: ...mpatible and select from the 15 formats listed on page 33 If you require a format other than those listed review the override options described in Location 18 to create the appropriate format In order to create a special format a 15 must be programmed in location 8 in addition to the entries in location 18 If this location contains a 0 format 1 will be used when phone N 2 is dialled LOCATION 9 DIA...

Страница 39: ... split reporting and the split is based on partition then location 10 should be programmed as 0 and location 11 should be used to select those partitions that are to be reported to phone N 2 If no events are to be reported to phone N 2 both locations should be at 0 LOCATION 10 EVENTS REPORTED TO PHONE N 2 2 segments of feature selection data Segment 1 1 Alarms 2 Opening and closings 3 Zone bypass ...

Страница 40: ...atible and select from the 15 formats listed on page 33 If you require a format other than those listed review the override options described in location 18 to create the appropriate format In order to create a special format a 15 must be programmed in location 14 in addition to the entries in location 18 If this location contains a 0 format 1 will be used when phone N 3 is dialled LOCATION 15 DIA...

Страница 41: ...rting and the split is based on partition then location 16 should be programmed to 0 and location 17 should be used to select those partitions that are to be reported to phone N 3 If no events are to be reported to phone N 3 both locations should be at 0 LOCATION 16 EVENTS REPORTED TO PHONE N 3 2 segments feature selection data Segment 1 1 Alarms 2 Opening and closings 3 Zone bypass and bypass res...

Страница 42: ...format no handshake required 2 On for 1400 2300 handshake 3 Reserved 4 Reserved 5 On for Contact ID 6 On for SIA 7 On for 3 digit event code 8 On for DTMF Segment 3 Reserved Segment 4 Inter digit time for pulse format The inter digit time is the value programmed on this location divided by the pulse rate PPS of the programmed format This is programmed in a binary way in order to program the value ...

Страница 43: ... On locks programming of all locations associated with the communicator can only be viewed from the keypad must be changed by downloading 7 On locks out download section If On locations 19 22 cannot be viewed from the keypad can only be viewed from the keypad when Off 8 On enables call back at auto test interval LOCATION 22 DOWNLOAD CALL BACK NUMBER 20 segments numerical data If a telephone number...

Страница 44: ...r feature keypad lockout Segment 2 1 On enables the LED extinguish feature 2 On enables the require code for bypassing feature 3 On enables the zone bypassed sounder alert feature 4 On enables the AC power low battery sounder alert feature 5 On enables bypass toggle 6 On enables silent auto arm 7 On enables the automatic instant feature of entry exit zones 8 On enables final set door Segment 3 1 O...

Страница 45: ...ll be used when a delay 1 zone type initiates an entry delay Valid entries are 10 255 seconds Segment 2 Exit time 1 This is the exit time that will be used for all zones designated as delay 1 Valid entries are 10 255 seconds Segment 3 Entry time 2 This is the entry time that will be used when a delay 2 zone type initiates an entry delay Valid entries are 10 255 seconds Segment 4 Exit time 2 This i...

Страница 46: ... armed and no entry or exit delay is being timed It is delayed during entry and exit delay times This zone will bypass automatically if enabled in segment 1 of location 23 6 2 INSTANT This zone creates an instant alarm whenever it is tripped and the armed LED is on 7 2 24 HOUR SILENT Creates an instant silent alarm regardless of the arming state of the control panel It will not display on the keyp...

Страница 47: ...rtition or partitions of the control panel where it is resident as long as the zone is shorted This zone type will disarm the partition or partitions of the control where it is resident as long as the zone is open Keyswitch arming will report as user 99 18 2 ENTRY EXIT DELAY 1 FORCE ARMABLE A trip will start entry delay 1 Absence of a trip during exit delay will enable the automatic bypass or inst...

Страница 48: ...ne creates an instant alarm whenever the system is armed This zone is force armable see feature definitions pages 5 11 28 2 INSTANT ZONE ACTIVITY MONITOR ENABLED This zone creates an instant alarm whenever the system is armed It will send a report if the zone activity time is reached without a change of state see location 40 segment 11 and locations 110 169 29 INSTANT ZONE WITH END OF LINE RESISTO...

Страница 49: ...nd for expander trouble 3 On for zones to restore immediately Off for zones to restore only when the siren is off or disarmed 4 On if dynamic battery test is performed at arming Off if dynamic battery test is performed at disarming See location 40 5 On if battery missing test is performed every 12 seconds 6 On if manual bell test is performed during 4 4 test function 7 On if manual communicator te...

Страница 50: ...X 7002 is enrolled by the panel and if the NX 7002 is used as backup GSM voice channel for the PSTN dialler of the panel Also telephone line monitoring needs to be enabled in location 40 Do not use this feature as the only backup feature of the PSTN dialler but use this in addition with the standard backup options as described in the NX 7002 manual LOCATION 38 SWINGER SHUTDOWN COUNT Location 38 co...

Страница 51: ...n time Segment 11 Zone activity monitor feature timed in hours days 0 255 0 disabled Segment 12 Auto arming warning timer 1 255 minutes Segment 13 Auto arming retry timer 1 255 minutes Segment 14 Programming Timeout 1 255 minutes 0 15 minutes LOCATION 41 CODE REQUIREMENTS 1 segment feature data Segment 1 1 On enables the 6 digit code option If 6 digit option is enabled all arm disarm codes and the...

Страница 52: ... arm disarm code can change user codes 5 On enables Go To Program Code as an arm disarm code 6 On enables Go To Program Code to bypass zones 7 On enables Go To Program Code opening and closing reports 8 Reserved Segment 2 Reserved LOCATION 44 DURESS CODE 6 segments numerical data Location 43 contains the Duress code This Location contains either 4 or 6 digits If the 6 digit code option is enabled ...

Страница 53: ...he opening and closing time in locations 52 and 53 6 On if output should be inverted 0 volts going to 12 volts when activated 7 Reserved 8 Reserved LOCATION 47 AUXILIARY OUTPUT 1 EVENT AND TIME 2 segments numerical data Segment 1 Use the chart below to select the event that will activate auxiliary output 1 relay 1 Segment 2 Program the timing from 0 255 minutes or seconds depending on the data pro...

Страница 54: ...xit 49 Key FOB function 1 20 Entry or exit 50 Key FOB function 2 21 Armed state 51 Always ON 22 Disarmed state 52 Autoarm warning time 23 Ready 53 Any siren when in away mode 24 Not ready 54 Progress of entry exit follows keypad buzzer 25 Fire 55 Auxiliary communication failure 26 Fire trouble 56 Radio test 27 Chime 57 Any siren when armed in any mode 28 Expander trouble 58 Alarm memory pulsating ...

Страница 55: ...nly valid on those days programmed in location 54 This is also the time when the panel will automatic disarm Note Opening time must be earlier than closing time so that autoarm Aux outputs or code authorisation can function properly Segment 1 Program the hour of the opening time Segment 2 Program the minutes after the hour of the opening time LOCATION 53 CLOSING TIME AUTOMATIC ARMING TIME 2 segmen...

Страница 56: ...ly after close window will arm disarm on Tuesday 4 Arm only after close window will arm disarm on Wednesday 5 Arm only after close window will arm disarm on Thursday 6 Arm only after close window will arm disarm on Friday 7 Arm only after close window will arm disarm on Saturday 8 Reserved LOCATION 55 DAYS OF THE WEEK FOR AUTO ARMING 1 Segment feature selection data Location 55 selects the days on...

Страница 57: ... 2 4 Reserved Segment 5 Zones 1 8 Restore Code Segment 6 8 Reserved LOCATION 57 BYPASS COMMUNICATOR CODE SLOW SPEED FORMATS ONLY 8 segments numerical data Location 57 contains the event code for a zone Bypass with a 4 2 and 3 1 format For a 4 2 format the digit programmed in this location will be sent as the tens digit As ones digit the zone number 1 8 will be reported e g zone 1 1 zone 8 8 When u...

Страница 58: ...ONLY 8 segments numerical data Location 61 contains the event code for a zone Sensor missing for a 4 2 and 3 1 format For a 4 2 format the digit programmed in this location will be sent as the tens digit As ones digit the zone number 1 8 will be reported e g zone 1 1 zone 8 8 To report a restore the restore code of location 56 will be used Segment 1 Zones 1 8 Sensor Missing Code Segment 2 8 Reserv...

Страница 59: ...ion Segment 1 contains the tens digit and segment 2 contains the ones digit For a 3 1 format only the segment 1 digit tens will be sent LOCATION 67 BOX TAMPER BOX TAMPER RESTORE COMMUNICATOR CODE SLOW SPEED FORMATS ONLY 4 segments numerical data Location 67 contains the tens and ones digits that will be sent for a 4 2 and 3 1 format if the Box Tamper feature is enabled in location 37 Segment 1 con...

Страница 60: ...cal data Location 71 contains the tens and ones digits for a 4 2 and 3 1 format that will be sent if siren supervision reporting is enabled Segment 1 contains the tens digit of the Bell Tamper Reporting Segment 2 contains the ones digit of the Bell Tamper Reporting Segment 3 contains the tens digit of the Bell Tamper Restore Segment 4 contains the ones digit of the Bell Tamper Restore For a 3 1 fo...

Страница 61: ... must be used Segment 1 Codes 1 8 Opening Code Segment 2 8 Reserved LOCATION 78 CLOSING COMMUNICATOR CODE SLOW SPEED FORMATS ONLY 8 segments numerical data Location 78 contains the tens digit for a 4 2 and 3 1 format if Closing Reporting is enabled For a 4 2 format the digit programmed in this section will be sent as the tens digit of the alarm event code As ones digit the user number will be repo...

Страница 62: ...End Program Reporting Segment 4 contains the ones digit of the End Program Reporting For a 3 1 format only the segment 1 digit resp segment 3 digit tens will be sent LOCATION 82 END DOWNLOAD COMMUNICATOR CODE SLOW SPEED FORMATS ONLY 4 segments numerical data Location 82 contains the tens and ones digits for a 4 2 and 3 1 format that will be sent if End Downloading Reporting is enabled Segment 1 an...

Страница 63: ...y 1 zone follows timer 1 Entry and Exit times 6 Delay 2 zone follows timer 2 Entry and Exit times 7 Interior turn on if this zone should Automatically Bypass or Bypass for Stay Arming 8 Local only turn on if this zone should not be reported Remark for a maintained keyswitch ON OFF program both keyswitch and local Segment 2 1 On if configuration group will beep the keypad for alarm 2 On if configur...

Страница 64: ...ta Use the Configuration Group Characteristic Selections described in Location 111 LOCATION 114 CONFIGURATION GROUP 3 ALARM EVENT CODE 1 segment numerical data Location 114 contains the event code that is sent for a Contact ID or SIA report The desired event code should be chosen from the list on pages 121 122 The zone ID will be the zone that is in alarm This location is not used for slow speed f...

Страница 65: ...tact ID or SIA report The desired event code should be chosen from the list on pages 121 122 The zone ID will be the zone that is in alarm This location is not used for slow speed formats like 4 2 and 3 1 This location may also contain the alarm report code for the Robofon format value 00 99 LOCATION 121 CONFIGURATION GROUP 6 CHARACTERISTIC SELECT 5 segments feature selection data Use the Configur...

Страница 66: ...127 CONFIGURATION GROUP 9 CHARACTERISTIC SELECT 5 segments feature selection data Use the Configuration Group Characteristic Selections described in Location 111 LOCATION 128 CONFIGURATION GROUP 10 ALARM EVENT CODE 1 segment numerical data Location 128 contains the event code that is sent for a Contact ID or SIA report The desired event code should be chosen from the list on pages 121 122 The zone...

Страница 67: ...tact ID or SIA report The desired event code should be chosen from the list on pages 121 122 The zone ID will be the zone that is in alarm This location is not used for slow speed formats like 4 2 and 3 1 This location may also contain the alarm report code for the Robofon format value 00 99 LOCATION 135 CONFIGURATION GROUP 13 CHARACTERISTIC SELECT 5 segments feature selection data Use the Configu...

Страница 68: ... 141 CONFIGURATION GROUP 16 CHARACTERISTIC SELECT 5 segments feature selection data Use the Configuration Group Characteristic Selections described in Location 111 LOCATION 142 CONFIGURATION GROUP 17 ALARM EVENT CODE 1 segment numerical data Location 142 contains the event code that is sent for a Contact ID or SIA report The desired event code should be chosen from the list on pages 121 122 The zo...

Страница 69: ...tact ID or SIA report The desired event code should be chosen from the list on pages 121 122 The zone ID will be the zone that is in alarm This location is not used for slow speed formats like 4 2 and 3 1 This location may also contain the alarm report code for the Robofon format value 00 99 LOCATION 149 CONFIGURATION GROUP 20 CHARACTERISTIC SELECT 5 segments feature selection data Use the Configu...

Страница 70: ...e the Configuration Group Characteristic Selections described in Location 111 LOCATION 156 CONFIGURATION GROUP 24 ALARM EVENT CODE 1 segment numerical data Location 156 contains the event code that is sent for a Contact ID or SIA report The desired event code should be chosen from the list on pages 121 122 The zone ID will be the zone that is in alarm This location is not used for slow speed forma...

Страница 71: ...21 122 The zone ID will be the zone that is in alarm This location is not used for slow speed formats like 4 2 and 3 1 This location may also contain the alarm report code for the Robofon format value 00 99 LOCATION 163 CONFIGURATION GROUP 27 CHARACTERISTIC SELECT 5 segments feature selection data Use the Configuration Group Characteristic Selections described in Location 111 LOCATION 164 CONFIGUR...

Страница 72: ...code that is sent for a Contact ID or SIA report The desired event code should be chosen from the list on pages 121 122 The zone ID will be the zone that is in alarm This location is not used for slow speed formats like 4 2 and 3 1 This location may also contain the alarm report code for the Robofon format value 00 99 LOCATION 169 CONFIGURATION GROUP 30 CHARACTERISTIC SELECT 5 segments feature sel...

Страница 73: ...the address from the location chart Keypad Part 1 1 192 2 200 3 208 4 216 5 224 6 232 7 240 8 248 LOCATION 213 PROGRAMMING THE COUNTRY CODE 1 segment numerical data The NX 4 has the ability to set different country codes Each country code has specific default settings Before start programming the NX 4 it is important to select the country code that is required see table below Once the country code...

Страница 74: ...6 Siren Telephone Fault 6 Failure To Communicate 7 Test Reports 7 Alarm Restore 4 34 8 Program Download Log Full 8 Tamper Restore 5 35 RESERVED 6 35 PHONE 2 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 7 35 PHONE 2 ACCOUNT CODE 10 10 10 10 10 10 8 35 PHONE 2 REPORTING FORMAT 0 9 35 PHONE 2 DIAL ATTEMPTS BACKUP CONTROL 8 0 PHONE 2 SELECTING EVENTS TO REPORT TO PHONE 2 Segment 1 Circl...

Страница 75: ...t Off 1900hz 1 On pager format no handshake required 2 On 2300hz handshake Off 1400hz 2 On 1400 2300 handshake 3 On chksum parity Off double round par 3 Reserved 4 On 2 digit event code Off 1 digit code 4 Reserved 5 On extended reporting Off non extended 5 On Contact ID 6 Reserved 6 On SIA 7 On 20 PPS Off 10 or 40 PPS 7 On 3 digit event code 8 On 10 PPS Off 20 or 40 PPS 8 On DTMF Segment 3 RESERVE...

Страница 76: ...to open 1 Disables auto bypassing of force armable zones 2 Auto arm in stay mode 2 Reserved 3 Enables instant night 3 Reserved 4 Tamper when sensor lost if armed 4 Reserved 5 Enables instant stay toggle 5 Reserved 6 Arming with tamper mem comm failure 6 Reserved 7 Arming with battery trouble 7 Reserved 23 41 8 Keyswitch zone arms in stay mode 8 Reserved ENTRY EXIT TIMERS Segment 1 Entry Time 1 30 ...

Страница 77: ...y power overcurrent report enabled 5 Siren supervision report enabled 6 Restore Telephone Line Cut report enabled 7 A B alarm 8 Expander trouble report enabled Segment 4 Circle Numbers To Program 1 Failure To Communicate report enabled 2 Log Full report enabled 3 Autotest report enabled 4 Start and End Programming report enabled 5 End Download report enabled 6 Sensor Low Battery report enabled 7 S...

Страница 78: ...wer Up Delay 0 60 seconds 0 Segment 4 Siren Time 1 255 minutes 3 Segment 5 Telephone Line Cut delay 0 255 seconds 0 Segment 6 Cross Zone Time 0 255 minutes 5 Segment 7 Chime Time in 50 mS increments 0 255 5 Segment 8 Dialer delay 0 255 seconds 0 Segment 9 Fire Alarm Verification Time 120 255 seconds 0 Segment 10 Listen In Time 0 255 seconds 0 Segment 11 Zone monitor timer hours days 0 255 0 Segmen...

Страница 79: ...46 50 Reserved 8 8 AUXILIARY OUTPUT 1 EVENT TIME open collector 1 Segment 1 Program the event number for output 1 7 Each siren activation 47 50 Segment 2 Program the timing for output 1 0 sec follow event AUXILIARY OUTPUT 2 EVENT TIME relays 2 and open collector 2 Segment 1 Program the event number for output 2 7 Each siren activation 48 50 Segment 2 Program the timing for output 1 0 sec follow ev...

Страница 80: ...Segment 1 Zone 1 8 Trouble Code 0 59 55 Segment 2 8 Reserved 0 SENSOR LOW BATTERY COMMUNICATOR CODE SLOW SPEED FORMATS ONLY Segment 1 Zone 1 8 Sensor Low Battery Code 0 60 55 Segment 2 8 Reserved 0 SENSOR MISSING COMMUNICATOR CODE SLOW SPEED FORMATS ONLY Segment 1 Zone 1 8 Sensor Missing Code 0 61 55 Segment 2 8 Reserved 0 COMMUNICATOR CODES FOR SLOW SPEED FORMATS ONLY 62 55 DURESS 0 0 63 55 AUXIL...

Страница 81: ... Fast Loop Response 5 Dialer Delay zone 2 Double End of Line Tamper zone 6 Swinger zone 3 Trouble zone Fire and Day zone 7 Restore reporting 4 Cross Zone 8 Listen In Segment 4 Circle Numbers To Program 1 Zone activity monitor 5 Reserved 2 End of line resistor defeat 6 Reserved 3 Zone acts as request to exit input 7 Reserved 4 Zone acts as acces control zone 8 Reserved Segment 5 Circle Numbers To P...

Страница 82: ...66 CONFIGURATION GROUP 19 ALARM EVENT CODE 7 147 66 CONFIGURATION GROUP 19 CHARACTERISTIC SELECT 6 1257 25678 148 66 CONFIGURATION GROUP 20 ALARM EVENT CODE 7 149 66 CONFIGURATION GROUP 20 CHARACTERISTIC SELECT 5 1245 25678 150 66 CONFIGURATION GROUP 21 ALARM EVENT CODE 20 151 66 CONFIGURATION GROUP 21 CHARACTERISTIC SELECT 24 125 278 152 67 CONFIGURATION GROUP 22 ALARM EVENT CODE 20 153 67 CONFIG...

Страница 83: ...right Inside the can there are four slots for board insertion two on the top and two on the bottom of the can These allow the PC board to be positioned vertically as shown in the diagram When you slide the board between the grooves of the slots make sure the terminal strip is toward the front opening toward you to allow for the wire connections Note For installation service or maintenance a set of...

Страница 84: ...RMINAL ANY COM TERMINAL ANY COM TERMINAL DOUBLED ZONE CONFIGURATION THE 3 74K RESISTOR IS FOR ZONES 1 4 THE 6 98K RESISTOR IS FOR ZONES 5 8 6 98K E O L 5 8 ANY ZONE TERMINAL 3 74K E O L 1 4 IF A DOUBLED ZONE IS USED AS A FIRE ZONE THE HIGH ZONE 5 8 IS NOT USABLE EUROPEAN 1E O L 2E O L ZONE DOUBLING ZONES 5 8 BLUE WHT GRAY BRN 6 98K BRN ZONE DOUBLING ZONES 1 4 ORG VIOLET YEL BRN 3 74K BRN E O L RES...

Страница 85: ...f device to KEYPAD Current is limited to 250 mA when output is negative and 250µA when output is positive KP DATA Connect to the data terminal on the keypads and the expanders Maximum wire run is 800 m with 2 mm wire The minimum wire sizes at 75 150 300 and 600 m are 0 12 0 33 0 83 and 1 3 mm respectively These numbers are for one keypad at the end of the wire and a voltage drop of max 2 Volts Whe...

Страница 86: ... or yelp Loop response selectable 50 ms or 500 ms Dimensions PCB board only 223 x 90 mm Weight PCB board only 206 g Classifications Security Grade 2 Environmental Class 2 Applied standards EMC EN50130 4 Environmental EN50130 5 Control and Indicating equipment Technical specifications NX 108 NX 116 NX 124 Operating power Nominal 12 Vdc Minimum maximum 9 Vdc 14 Vdc Operating temperature 0 50 C Dimen...

Страница 87: ...9 mA 29 mA Current consumption in alarm 55 mA 47 mA 55 mA Maximum all LED s ON sounder ON 90 mA 110 mA 130 mA Weight 264 g 264 g 270 g Technical specifications NX 148 Operating power Nominal 12 Vdc Minimum maximum 9 Vdc 14 Vdc Operating temperature 0 50 C Dimensions 158 x 135 x 30 mm Current consumption 20 mA Nominal quiescent minimum lighting 25 mA Nominal quiescient maximum lighting 48 mA Curren...

Страница 88: ...MPER RESTORE device number 137 TR KEYPAD TAMPER 137 TA KEYPAD PANIC audible 120 PA KEYPAD PANIC silent 121 HA DURESS 121 HA KEYPAD AUXILIARY 1 110 FA KEYPAD AUXILIARY 2 100 MA RF SENSOR LOST zone number 381 T RF SENSOR RESTORE zone number 381 R SENSOR LOW BATTERY zone number 384 XT SENSOR BATTERY RESTORE zone number 384 XR ZONE TROUBLE zone number 380 T ZONE TROUBLE RESTORE zone number 380 R ZONE ...

Страница 89: ...ion group event code Programmed Event Code SIA Code Description 0 HA Holdup Alarm 1 FA Fire Alarm 2 PA Panic alarm 3 BA Burglary Alarm 4 BA Burglary Alarm 5 BA Burglary Alarm 6 UA Untyped Alarm 7 BA Burglary Alarm 8 BA Burglary Alarm 9 UA Untyped Alarm 10 HA Holdup Alarm 11 MA Medical Alarm 12 PA Panic alarm 13 TA Tamper Alarm 14 RP Periodic Test 15 GA Gas Alarm 16 KA Heat Alarm 17 WA Water Alarm ...

Страница 90: ...22 Silent Panic 1 110 Fire Alarm 2 120 Panic alarm 3 130 Burglary Alarm 4 131 Perimeter Alarm 5 132 Interior Alarm 6 133 24 Hour Burglary 7 134 Entry Alarm 8 135 Day Night Alarm 9 150 Non Burglary 24 Hour 10 121 Duress Alarm 11 100 Medical Alarm 12 123 Audible Panic Alarm 13 137 Tamper Alarm 14 602 Periodic Test 15 151 Gas Detected 16 158 High Temp 17 154 Water Leakage 18 140 General Alarm 19 140 ...

Страница 91: ... 4 216 5 224 6 232 7 240 8 248 Wireless receiver NX 448E Wireless receiver DIP 1 DIP 2 DIP 3 Expander number reported 1 OFF 35 OFF OFF 2 ON OFF OFF 36 3 OFF ON OFF 37 4 ON ON OFF 38 5 OFF OFF ON 39 6 ON OFF ON 32 7 OFF ON ON 33 8 ON ON ON 34 Output module NX 507E or NX 508E Output module DIP 1 DIP 2 DIP 3 Expander number reported 1 ON ON OFF 24 2 OFF OFF ON 25 3 ON OFF ON 26 4 OFF ON ON 27 5 ON 28...

Страница 92: ...CE DECLARATION NX 4 EUR Installation manual Page 92 02 07 06 ...

Страница 93: ...NX 4 EUR Installation manual Page 93 02 07 06 ...

Страница 94: ...NX 4 EUR Installation manual Page 94 02 07 06 ...

Страница 95: ...NX 4 EUR Installation manual Page 95 02 07 06 ...

Страница 96: ...NX 4 EUR Installation manual Page 96 02 07 06 ...

Страница 97: ...NX 4 EUR Installation manual Page 97 02 07 06 ...

Страница 98: ...NX 4 EUR Installation manual Page 98 02 07 06 ...

Страница 99: ...NX 4 EUR Installation manual Page 99 02 07 06 ...

Страница 100: ...sion of GE Security EMEA bvba COPYRIGHT 2006 GE Security EMEA bvba All rights reserved GE Security EMEA bvba grants the right to reprint this manual for internal use only GE Security EMEA bvba reserves the right to change information without notice ...