TEST FUNCTION – Optional 

If programmed, this function will perform a battery test, communicator test, and/or 
a siren test. No alarms will be sent and no reports will be sent unless a 
communicator test is performed, at which time a test signal will be sent. 

 
Step 1 

Press [

r

]-[4].  The test will be performed as programmed. 

 
Step 2 

If the siren test is performed, enter a user code to silence the siren. 

WALK TEST 

If enabled, it will permit a temporary walk-through test where all zones become 
silent and do not report alarms to the central station.  
 

Step 1 

Press  [

r

]-[Chime]-[user code].  During this test the chime light will 

flash on the LED keypad.   

Step 2 

Each time a zone is faulted, the zone light on the LED keypad will 
illuminate and the chime will sound. The number of the faulted 
zone(s) will be displayed on the LCD keypad.  It will also be entered 
into alarm memory and the internal log.   

Step 3 

The keypad will begin to beep after 15 minutes in this mode.  This 
beeping indicates that the “Walk-Test” mode will be automatically 
exited in 5 minutes. 

Step 4 

To exit at any time during this mode, enter a user code.  Otherwise 
the 

A

Walk-Test Mode

@

 will automatically exit after 20 minutes.   

RESET FUNCTION 

This function is used to reset Smoke Detectors, Zone Troubles, and Zone 
Tampers. 
 

Step 1 

Disarm the system if not disarmed. 

 
Step 2 

Press [

r

]-[7].   Resets have now been performed. 

 
Step 3 

If the keypad begins beeping, the reset did not execute properly. 
Enter your code to silence the keypad. Wait a few minutes and 
repeat step 2 to attempt another reset. If the keypad still beeps after 
repeated attempts, please contact your installer. 

SETTING THE SYSTEM DATE 

Step 1 

Press the [

r

]-[9]-[6]. 

 
Step 2 

Enter the “Master Code”.  

 

Содержание NX-108E - Security NetworX NX-4 System

Страница 1: ...NETWORX TM NX 4 User manual...

Страница 2: ...te a previous alarm INSTANT Light is on when there is no entry exit delay FIRE Light is on to indicate fire alarm flashes to indicate a trouble condition with your fire system ZONE LIGHTS are on stead...

Страница 3: ...s s Auto Bypass s Chime Quick Arm s Auto Instant Communicator Test Re Exit Battery Test Forced Arming s Siren Test s These features should not be enabled on UL listed systems ENTRY EXIT DELAY TIMES Ex...

Страница 4: ...F SECURITY YOU WILL OBTAIN WITH THIS SYSTEM RELATES SPECIFICALLY WITH TWO MAJOR FACTORS 1 The quantity quality and placement of security devices attached to this system 2 The knowledge you have of the...

Страница 5: ...Arming Your System In The Stay Mode 7 Using The Quick Arm 8 Disarming Your System 8 Cancel Abort Feature 9 Bypassing Zones 9 Group Bypass 9 Unbypassing 9 Turning The Door Chime On And Off 9 CHANGING U...

Страница 6: ...ress PIN in lieu of the User PIN will operate normally without additional audible or visual indicators Forced Arming An option that allows the system to be turned on ARMED with one or more zones open...

Страница 7: ...t is on during the exit delay During the last 10 seconds of the exit delay the exit light will flash rapidly and the keypads will beep rapidly as a warning to the user that the exit time is about to e...

Страница 8: ...programmed for these functions the following reports can be sent Fire Key This key can activate the fire alarm when pressed for two seconds If your system is connected to a monitoring center an emerg...

Страница 9: ...end of the exit delay the keypads beep one longer tone 1 second The user may wish to disarm and re arm the system if more time is needed ARMING YOUR SYSTEM IN THE STAY MODE STAY is used when the user...

Страница 10: ...or ARMING ONLY and will not disarm the security system This is ideal for a maid or baby sitter code etc CHANGING MODES WHILE YOUR SYSTEM IS ARMED Pressing the STAY key will turn on off toggle a delay...

Страница 11: ...ASS key again Step 5 The corresponding zone light will illuminate indicating the zone has been bypassed Repeat steps 3 and 4 for any other zone s that need to be bypassed Step 6 Press the BYPASS key a...

Страница 12: ...r code needs to be programmed return to Step 5 Step 9 Press the key while the ready light is flashing to exit the User Code Programming Mode ASSIGNING USER CODE AUTHORITY LEVELS Assign authority level...

Страница 13: ...to all user numbers Step 7 Press the key to exit the Assigning Authority Level Program OTHER KEYPAD FUNCTIONS SETTING THE KEYPAD TONE Step 1 Press r 0 Keypad is now in the Adjust Tone mode Step 2 Pres...

Страница 14: ...d The number of the faulted zone s will be displayed on the LCD keypad It will also be entered into alarm memory and the internal log Step 3 The keypad will begin to beep after 15 minutes in this mode...

Страница 15: ...For 2007 enter 0 7 SETTING THE SYSTEM CLOCK Step 1 Press r 9 7 Step 2 Enter the Master Code Step 3 Enter the hour code which must be two 2 digits Note The clock is a 24 hour clock Refer to the followi...

Страница 16: ...idly for the last 10 seconds of an exit delay and beeps 1 second at the end of the exit delay Pulses when the armed status changes and the AC power is off Pulses when the armed status changes and any...

Страница 17: ...that are tampered Press the key to return to the 1 of 8 service lights 3 ZONE LOW BATTERY Press the 3 key The zone light s will illuminate showing which zone s has a low battery This only applies to w...

Страница 18: ...dures In a home sleep with bedroom door closed this will increase your escape time If you suspect fire test the door for heat If you think it is safe brace your shoulder against the door and open it c...

Страница 19: ...17 SYSTEM NOTES...

Страница 20: ...NX 4 USER S MANUAL NX4UD04 REV D FEB 2004...

Отзывы: