background image

UNDERSTANDING THE LIGHTS 

Armed Light 

The  armed light is “on” when the system is armed.  The armed light is “off” 
when it is disarmed.  The armed light will flash when there has been an alarm 
during the previous arm cycle. 

Bypass Light 

The  bypass light is “on” when any zone is bypassed. The zone(s) that is 
bypassed will also be illuminated.  If the bypass light is “off”, no zones are 
bypassed. 

Cancel Light 

The  cancel light will flash during an abort delay time.  If a code is entered 
followed by the [CANCEL] key while this light is flashing, all abortable reports 
will stop the communication process. Note: The abort feature must be 
enabled
. Entering a code followed by the [CANCEL] key during or after an 
alarm report to the central station will cause the cancel light to come on. It will 
stay on until the central station has received the cancel report. Note: The 
cancel feature must be enabled.
 No additional keypad tones will be emitted. 

Chime Light 

The chime light is “on” when the chime feature is “on”;  “off” otherwise. 

Exit Light 

The exit light is “on” during the exit delay. During the last 10 seconds of the exit 
delay, the exit light will flash rapidly and the keypads will beep rapidly as a 
warning to the user that the exit time is about to expire. (The user may want to 
disarm the system if the exit light is flashing in order to prevent an alarm. The 
user may then re-arm the system and exit before the delay expires.) 

Fire Light 

A steady fire light means a fire zone has been faulted. A rapidly flashing fire 
light
 means that a fire zone is in a trouble condition. 

Instant Light 

The instant light is “on” when there is no delay on your entry/exit door(s). Any 
time the instant light
 is “on” and the exit delay has expired, the opening 
of an entry/exit door will produce an immediate alarm
. The instant light can 
be toggled on or off by pressing the [Stay] key while the system is armed. 
When the instant light is “off”, the entry/exit door(s) is delayed.  

Power Light 

The power light is on if the primary power is on. The power light will flash if the 
system has a low battery condition. 

Ready Light 

The ready light is “on” when the system is ready to arm and “flashes” if ready to 
force arm. The ready light is off when the system is not ready to arm because 
of a zone(s) being faulted. 

Содержание NX-108E - Security NetworX NX-4 System

Страница 1: ...NETWORX TM NX 4 User manual...

Страница 2: ...te a previous alarm INSTANT Light is on when there is no entry exit delay FIRE Light is on to indicate fire alarm flashes to indicate a trouble condition with your fire system ZONE LIGHTS are on stead...

Страница 3: ...s s Auto Bypass s Chime Quick Arm s Auto Instant Communicator Test Re Exit Battery Test Forced Arming s Siren Test s These features should not be enabled on UL listed systems ENTRY EXIT DELAY TIMES Ex...

Страница 4: ...F SECURITY YOU WILL OBTAIN WITH THIS SYSTEM RELATES SPECIFICALLY WITH TWO MAJOR FACTORS 1 The quantity quality and placement of security devices attached to this system 2 The knowledge you have of the...

Страница 5: ...Arming Your System In The Stay Mode 7 Using The Quick Arm 8 Disarming Your System 8 Cancel Abort Feature 9 Bypassing Zones 9 Group Bypass 9 Unbypassing 9 Turning The Door Chime On And Off 9 CHANGING U...

Страница 6: ...ress PIN in lieu of the User PIN will operate normally without additional audible or visual indicators Forced Arming An option that allows the system to be turned on ARMED with one or more zones open...

Страница 7: ...t is on during the exit delay During the last 10 seconds of the exit delay the exit light will flash rapidly and the keypads will beep rapidly as a warning to the user that the exit time is about to e...

Страница 8: ...programmed for these functions the following reports can be sent Fire Key This key can activate the fire alarm when pressed for two seconds If your system is connected to a monitoring center an emerg...

Страница 9: ...end of the exit delay the keypads beep one longer tone 1 second The user may wish to disarm and re arm the system if more time is needed ARMING YOUR SYSTEM IN THE STAY MODE STAY is used when the user...

Страница 10: ...or ARMING ONLY and will not disarm the security system This is ideal for a maid or baby sitter code etc CHANGING MODES WHILE YOUR SYSTEM IS ARMED Pressing the STAY key will turn on off toggle a delay...

Страница 11: ...ASS key again Step 5 The corresponding zone light will illuminate indicating the zone has been bypassed Repeat steps 3 and 4 for any other zone s that need to be bypassed Step 6 Press the BYPASS key a...

Страница 12: ...r code needs to be programmed return to Step 5 Step 9 Press the key while the ready light is flashing to exit the User Code Programming Mode ASSIGNING USER CODE AUTHORITY LEVELS Assign authority level...

Страница 13: ...to all user numbers Step 7 Press the key to exit the Assigning Authority Level Program OTHER KEYPAD FUNCTIONS SETTING THE KEYPAD TONE Step 1 Press r 0 Keypad is now in the Adjust Tone mode Step 2 Pres...

Страница 14: ...d The number of the faulted zone s will be displayed on the LCD keypad It will also be entered into alarm memory and the internal log Step 3 The keypad will begin to beep after 15 minutes in this mode...

Страница 15: ...For 2007 enter 0 7 SETTING THE SYSTEM CLOCK Step 1 Press r 9 7 Step 2 Enter the Master Code Step 3 Enter the hour code which must be two 2 digits Note The clock is a 24 hour clock Refer to the followi...

Страница 16: ...idly for the last 10 seconds of an exit delay and beeps 1 second at the end of the exit delay Pulses when the armed status changes and the AC power is off Pulses when the armed status changes and any...

Страница 17: ...that are tampered Press the key to return to the 1 of 8 service lights 3 ZONE LOW BATTERY Press the 3 key The zone light s will illuminate showing which zone s has a low battery This only applies to w...

Страница 18: ...dures In a home sleep with bedroom door closed this will increase your escape time If you suspect fire test the door for heat If you think it is safe brace your shoulder against the door and open it c...

Страница 19: ...17 SYSTEM NOTES...

Страница 20: ...NX 4 USER S MANUAL NX4UD04 REV D FEB 2004...

Отзывы: