NetworX Version 3 Installation Manual
81
Location
Term
Definition
2.4.2.5
Answer Machine Defeat
A menu entry used to defeat an answering machine. If two-
call Answer Machine Defeat AMD is enabled, two telephone
calls are required to defeat the answering machine. On the
first call, the phone rings once or twice. The control panel
detects the rings and starts a 45-second timer. During this
timer, the control panel answers the next call on the first
ring. This is not recommended for commercial applications.
2.4.2.6
Call PC on Autotest
A menu option that allows the panel to use call back when
the central station performs an autotest. After the test
report is delivered to the central station, the panel calls the
up/download software using the call back phone number.
Actions, such as upload event log and download phone
numbers, can be selected in the up/download software.
2.4.2.7
Require Code for Download
A menu option that requires a user code to be entered
before downloading can start.
2.4.2.8 Lockout
A menu entry that groups options that lock certain system
functions.
2.4.2.8.1 System
Shutdown
A menu option that allows the up/download software to
shutdown the control panel. This option can be set only
from the up/download software. The shutdown LCD
message is shown to explain the reason for the shutdown.
During shutdown the system is completely inactive. It is not
possible to arm/disarm the system and no reports or sirens
are activated.
2.4.2.8.2 Local
Programming
A
Communications
menu option that disables the installer
menu. This option can be set only through the
up/download software.
2.3.2.8.3 Comms
Settings
A menu option that prevents the installer changing the
communication settings (telephone numbers, account
codes and so on). This option must be set using the
up/download software.
2.4.2.8.4 Download
Settings
A menu option that prevents the installer changing the
following download settings:
Answer Machine Defeat
Callback Required
Lockout>System Shutdown
Lockout>Local Programming
Lockout>Comms Settings
Lockout>Download Settings
Call PC on Autotest
This option must be set through the up/download
software.
2.4.3 Autotest
A menu entry that groups options that configure the
automatic test run by the system.
2.4.3.1 Hours/Days?
A menu option that specifies whether the autotest occurs
after a specified number of days or hours. The autotest can
be suppressed if another report has been sent.
2.4.3.2 Interval
A menu option that sets the length of time between
autotests. The basic unit is set in the Hours/Days? option.
The
Hour
and
Minute
options set the time at which the test
Содержание NetworX V3
Страница 1: ...NetworX Version 3 Alarm System Installation Manual 1070138 ...
Страница 10: ...NetworX Version 3 Installation Manual 10 Section A Installing and programming a basic system ...
Страница 50: ...NetworX Version 3 Installation Manual 50 Section B Programming the system ...
Страница 257: ...NetworX Version 3 Installation Manual 257 Section C References ...
Страница 286: ...NetworX Version 3 Installation Manual 286 ...