Location
Term
Definition
option is visible only if the
Keyswitch
input type option is
enabled.
2.1.3.1.3.11
Req. To Exit
A zone characteristic that enables the zone to act as a
request to exit input.
2.1.3.1.3.12 Holdup
A zone characteristic that enables the zone to act as a
holdup zone. The holdup zone can be activated by a
switch, a push button, or a panic button on a keyfob
assigned to the holdup zone type. Holdup is a silent alarm
with reported HA SIA code. See Appendix 7 for more
information.
2.1.3.1.4 Sound
A menu entry that groups sounder characteristics for a
particular zone type. These characteristics determine the
sounds produced by the sirens and keypads when the
selected zone is activated.
2.1.3.1.4.1
Yelping Siren (Burglary)
A menu option that sounds a burglary siren when a zone is
activated.
2.1.3.1.4.2 Steady
Siren
(Fire)
A menu option that sets whether a zone type activates a
fire or a burglary siren.
2.1.3.1.4.3 Audible
Keypad
A menu option that activates the keypad buzzer when an
alarm occurs.
2.1.3.1.4.4 Chime
A menu option that sets whether a zone type activates a
chime.
A chime is generally a single stroke signal and is often used
as an indication on a shop door. This can be set as a zone
type. There is a beep on chime activation and no beep on
deactivation.
2.1.3.1.5 Reporting
A menu entry that groups reporting options for the
selected zone type.
2.1.3.1.5.1
Local Only
A zone characteristic that causes that zone not to report
alarms to the central station. Locally, the sirens are
activated according to the other zone type characteristics.
This option is visible only if the
Keyswitch
input type option
is disabled.
2.1.3.1.5.2 Restore
Reporting
A menu option that causes restore events to be reported to
the central station.
2.1.3.1.5.3 Dialer
Delay
A menu option that sets the length of time (in seconds) the
dialer waits before reporting an abortable alarm. If the
system is disarmed during this time, the abortable alarm is
not sent to the central station. The delay can be from 0-255
seconds. A value of 0 means that there is no abort delay.
Содержание NetworX V3
Страница 1: ...NetworX Version 3 Alarm System Installation Manual 1070138 ...
Страница 10: ...NetworX Version 3 Installation Manual 10 Section A Installing and programming a basic system ...
Страница 50: ...NetworX Version 3 Installation Manual 50 Section B Programming the system ...
Страница 257: ...NetworX Version 3 Installation Manual 257 Section C References ...
Страница 286: ...NetworX Version 3 Installation Manual 286 ...