NX-6V2-Control Panel
Installation Instructions
8
ANSI/SIA CP-01 requirements
CP-01 feature descriptions and specifications are listed in
Table 7
. The following are requirements for compliance with ANSI/SIA
CP-01 standards.
Note:
Where a conflict exists, UL requirements take precedence over ANSI/SIA requirements.
• Minimum system requirements:
• One control panel
• Two keypads
• Do not enable remote arming in SIA classified installations.
• Off premise transmission must be in the SIA format.
• Do not exceed 1 minute for the
abort
window and
entry delay
.
Note:
A call-waiting cancel on a noncall-waiting line prevents successful connection to the central station.
Table 7.
CP-01 feature descriptions and specifications
CP-01 feature description
Feature description as shown in
manual
Program
location
Seg/opt
Default
CP-01 required setting
Exit time
Exit 1 delay
24
2
60
45 to 240 seconds
Exit 2 delay
24
4
60
45 to 240 seconds
Progress annunciation / disable -
for silent exit
Silent keypad option
93
a
a.
Refer to your keypad installation manual.
2
All annunciators
enabled
Allowed (individual keypads
may be disabled)
Exit time restart (reexit)
This feature is not programmable in the panel.
Enabled
Auto stay arm on unvacated
premises
Auto bypass
23
1/3
Enabled
Enabled
Exit time and progress annuncia-
tion/disable for remote arm
This feature is not programmable in the panel. Exit time and progress are always enabled.
Enabled (disabled for remote
arming)
Entry delays
b
b.
Combined abort window time and entry delay must not exceed one minute.
Entry 1 delay
24
1
30
30 to 240 seconds
Entry 2 delay
24
3
30
30 to 240 seconds
Abort window - for
nonfire zones
Dialer delay
40
8
30
Enabled (may be disabled by
zone/zone type, but no cancel
reports will be sent)
Abort window time - for nonfire
zones
b
Dialer delay
40
8
30
15 to 45 seconds
Abort annunciation
This feature is not programmable in the panel. Flashing cancel LED goes off when
disarming.
Enabled
Cancel annunciation
Cancel
23
3/6
Enabled
Enabled
Duress feature
Duress
44
Disabled
Disabled
Cross zoning
Two trips on cross zone
37
5/4
Disabled
Required
Keypad sounds on cross zone trip
39
5
Disabled
Zone type characteristic
111
3/4
Disabled
Programmable cross zoning time
Cross zone time
40
6
5 minutes
Allowed
Swinger shutdown
Swinger shutdown count
38
n/a
Enabled for 1 trip
For all nonfire zones, shut
down at 1 to 2 trips
Swinger shutdown disable
Swinger shutdown count
38
n/a
Enabled for 1 trip
Allowed
Fire alarm verification
Fire alarm verification time
40
9
Disabled
Required (depends on panel
and sensors)
Call waiting cancel
Must be programmed as part of the
phone number
0
n/a
n/a
Required (depends on user
phone line)
Default changes (from prior
versions):
Recent closing
23
3/7
Enabled
Exit error
23
3/8
Enabled
Power up delay
40
3
60 seconds