Step 2 

• 

Enter your 4 or 6 digit user code to arm the system.  

• 

The armed and exit lights will illuminate. 

• 

You may now leave the building. 

 

NOTE:  The exit light will flash rapidly for the last 10 seconds of the exit 

delay as a warning to the user that the exit time is about to expire. The user 

may wish to disarm and rearm the system if more time is needed. 

 

 
ARMING YOUR SYSTEM IN THE “STAY” MODE 
STAY is used when the user is inside the premise and wants protection 

around the perimeter. Listed below are the steps to arm in the STAY Mode: 

 

Close all protected doors and windows. 

Step 1  

• 

Ready  light  must  be  on  or  flashing when all protected zones and

sensors are secure. NOTE:  If any zones are bypassed, a sensor in

that zone can be violated without affecting the ready light. 

• 

The security system will not arm if the ready light is not on or

flashing. 

• 

If the power light is off, you have no AC power. Restore power if

possible. If not, contact your installing company listed on page 1 of

this booklet for service. 

 

Step 2 

• 

Enter your 4 or 6 digit user code. 

• 

If “Auto Bypass” is enabled, all interior zones will be bypassed if you

do not leave through a designated entry/exit door.  If Auto Bypass is

enabled, omit Step 3. 

• 

When “Auto Instant” is enabled, if you do not leave through a

designated entry/exit door the instant light will illuminate indicating

that the entry/exit doors no longer have an entry delay. If “Auto

Instant” is enabled, omit Step 4. 

 

Step 3 

• 

Press the [STAY] key. 

• 

The  stay light will illuminate indicating that all interior zones are

bypassed.  (All interior devices will bypass automatically, giving the

user freedom of movement within the interior area.) 

• 

The  bypass light will illuminate if any zone(s) are bypassed. If any

zone(s) have been bypassed previously by the user, the light(s)

corresponding to the bypassed zone(s) will illuminate, alerting the

user that a zone(s) may be unprotected and can be faulted without

an alarm. 

 

Step 4 

• 

To toggle from a “delayed entry” mode to an “Instant” mode, press

the [STAY] key again. 

• 

The  instant light will illuminate indicating that the entry/exit doors

have no entry delay. 

Page 8 

Содержание NetworX NX-1500E

Страница 1: ...NetworX Series NX 1500E LED Keypad User Manual ...

Страница 2: ......

Страница 3: ...e Quick Arm Battery Test Communicator Test Re Exit Siren Test ENTRY EXIT DELAY TIMES Exit Delay Time __________ Secondary Exit Delay Time ________ Entry Delay Time _________ Secondary Entry Delay Time _______ ZONE DESCRIPTIONS 01 __________________________ 09 __________________________ 02 __________________________ 10 __________________________ 03 __________________________ 11 ____________________...

Страница 4: ...s mean will help you to easily operate your system Keep in mind the level of security you will obtain with this system relates specifically with two major factors 1 The quantity quality and placement of security devices attached to this system 2 The knowledge you have of the security system and how that knowledge is utilized in a weekly test of the complete system You should be aware of the follow...

Страница 5: ...NG THE QUICK ARM Optional see page 1 9 CHANGING MODES WHILE SYSTEM IS ARMED 9 DISARMING THE SYSTEM 9 CANCEL ABORT FEATURE Optional see page 1 9 BYPASSING ZONES 12 GROUP BYPASS 12 UNBYPASSING 12 TURNING THE DOOR CHIME ON AND OFF 12 ADDING AND CHANGING USER CODES 13 ASSIGNING USER CODE AUTHORITY LEVELS 13 OTHER KEYPAD FUNCTIONS 15 SETTING THE KEYPAD TONE 15 VIEW ALARM MEMORY 15 TEST FUNCTION Optiona...

Страница 6: ...operated under duress Forced Arming An option that allows the system to be turned on ARMED with one or more zones open A system that is ready to be force armed will flash the ready light Note Those zones that are not ready will not create an alarm Function Code A Function Code is either a four 4 or six 6 digit code that has been programmed by the installer to operate a device Group Bypass An optio...

Страница 7: ... by the CANCEL key while this light is flashing all abortable reports will stop the communication process Note The abort feature must be enabled Entering a code followed by the CANCEL key during or after an alarm report to the central station will cause the cancel light to come on It will stay on until the central station has received the cancel report Note The cancel feature must be enabled CHIME...

Страница 8: ...when the system is ready to arm and flashes if ready to force arm The ready light is off when the system is not ready to arm because of a zone s being faulted STAY LIGHT The stay light is on when the all interior motion detector zones are bypassed ZONE LIGHT The zone lights are off when everything is normal A zone light will be on if the zone has been bypassed If a zone light is flashing that zone...

Страница 9: ...conds If your system is connected to a monitoring center an emergency report could be transmitted to that center NOTE Some Panic Hold Up alarms are programmed to be silent at the protected site while reporting an alarm to the monitoring center Check with your installing company to determine how your security system will respond to the Panic Hold Up activation KEYPAD FUNCTIONS ARMING YOUR SYSTEM IN...

Страница 10: ...pany listed on page 1 of this booklet for service Step 2 Enter your 4 or 6 digit user code If Auto Bypass is enabled all interior zones will be bypassed if you do not leave through a designated entry exit door If Auto Bypass is enabled omit Step 3 When Auto Instant is enabled if you do not leave through a designated entry exit door the instant light will illuminate indicating that the entry exit d...

Страница 11: ...essing the STAY key again DISARMING THE SYSTEM When you enter the protected area through one of the designated Entry Exit doors the keypad control will sound a continuous tone for the duration of the entry delay time or until you enter a valid code The red armed light will go off and the tone will stop The security system is now DISARMED If a valid code is not entered before the end of the entry d...

Страница 12: ...r zone fault fast flash for service condition 5 FUNCTION KEYS perform various functions NUMERIC CODE ENTRY KEYS 3 PROGRAMMABLE EMERGENCY ACTIVATION KEYS The door is detachable and can be removed or replaced when desired The appropriate boxes should be marked on the door of your keypad for the Emergency Activation keys that are programmed to work with your system This system is is not partitioned Y...

Страница 13: ...t will stop flashing upon exiting the Bypass Mode GROUP BYPASS By pressing the BYPASS key followed by the 0 key then the BYPASS key again all zones that are designated as group bypass zones will be bypassed Press the BYPASS key again to exit group bypassing UNBYPASSING To manually unbypass zones perform the bypassing procedure on a zone that is already bypassed The corresponding light for that zon...

Страница 14: ... you are back at Step 2 above If the code is rejected the sounder will beep 3 times Step 6 If another user code needs to be programmed return to Step 3 Step 7 Press the key while the ready light is flashing to exit the User Code Programming Mode ASSIGNING USER CODE AUTHORITY LEVELS Assign authority levels to users by following the steps below Assign user codes before assigning authority levels Ste...

Страница 15: ...ser has access To change any of the partitions where the user has access press numbers corresponding to areas where you want to give the user access or deny access Example If zone light 2 is lit then the user is assigned access to partition 2 By pressing the 2 key the light will go off denying access to partition 2 Refer to chart shown below LIGHT PARTITIONS ASSIGNED 1 Partition 1 2 Partition 2 3 ...

Страница 16: ... Step 4 If another key is pressed the system will remain in the new partition until no keys have been pressed for 60 seconds VIEW ALARM MEMORY Step 1 Press r 3 The zone s that created the last alarm will be displayed on the keypad Step 2 The ALARM MEMORY feature will flash those zones that created alarms and will light steady those zones that were bypassed during the last alarm TEST FUNCTION Optio...

Страница 17: ... Day of Week 1 Sunday 3 Tuesday 5 Thursday 7 Saturday 2 Monday 4 Wednesday 6 Friday Step 3 Enter the Month Code Must always be two 2 digits 01 January 05 May 09 September 02 February 06 June 10 October 03 March 07 July 11 November 04 April 08 August 12 December Step 4 Enter the Day Code Must always be two 2 digits Example The 5th would be entered as 0 5 Step 5 Enter the last two digits of the Year...

Страница 18: ... followed by the 2 key to determine the service condition One or more zone lights will illuminate indicating what service s is required Call your service provider immediately for these problems Below is a listing of what each light means in a service condition TO EXIT THE SERVICE LIGHT MODE PRESS THE KEY LIGHT PROBLEM 1 SYSTEM FAULT Press the 1 key The zone light s that is illuminated corresponds ...

Страница 19: ...tion device failure 6 The service light will remain lit until the trouble clears and a user code is entered SEE NOTE 7 FAILURE TO COMMUNICATE This light will illuminate when there is a failure to communicate between your system and the central station SEE NOTE 8 LOSS OF SYSTEM TIME This light will illuminate when there has been a loss of power and your system clock needs to be reset Instructions a...

Страница 20: ...ng steps are recommended by the National Fire Protection Association and can be used as a guide in establishing an evacuation plan for your building Draw up a floor plan of your home Show windows doors stairs and rooftops that can be used for escape Indicate each occupant s escape routes Always keep these routes free from obstruction Determine two means of escape from each room One will be the nor...

Страница 21: ...stalled in accordance with the National Fire Protection Association s Standard 72 For additional information write the National Fire Protection Association Batterymarch Park Quincy MA 02269 The following are examples of evacuation plans A plan unique to your home or business should be drawn and memorized by each occupant Page 20 ...

Страница 22: ...SYSTEM NOTES Page 21 ...

Страница 23: ...NX1500E SERIES USER S MANUAL NX1500EUC04 REV C DEC 2004 ...

Отзывы: