GE Monogram ZVC30LSS Скачать руководство пользователя страница 8

Advance Planning

ADVANCE PLANNING

Ductwork Planning

•This hood is equipped for 8

round ductwork. 

•Determine the exact location of the vent hood.
•Plan the route for venting exhaust to the outdoors.

This hood is not designed for a recirculating
venting operation.

•Use the shortest and straightest duct route 

possible. For satisfactory performance, duct run
should not exceed 100 ft. equivalent length for any
duct configurations. 

•Refer to “Duct Fittings” chart to compute the 

maximum permissible length for duct runs to 
the outdoors.

•Use rigid metal ductwork only.
•Install a wall or roof cap with damper at the

exterior opening. Order the cap and any transitions
needed in advance.

Wall and Ceiling Framing for Adequate Support

This vent hood is heavy and the cabinet structure
needs to support the weight of the loaded insert
sleeve. Adequate structural support must be
provided in all types of installations. 
•Installation will be easier if the vent hood is

installed before the cooktop is installed.

Custom Cabinet Frame Planning

•The custom-built canopy should be sized to

accommodate the hood insert, and ducting
dimensions in the bottom of cabinet should be 
26

W by 13-3/16

D for the 30

and 36

models

and 38-3/4

″ 

W by 13-3/16

D for the 48

models.

Remote Mounting of the Control (Wired)

•The control can be remotely mounted on the wall

or the countertop.

•It is recommended that you use a professional

installer for the countertop cutout.

•It is recommended that the cutout in a granite

countertop or other hard surface be made before
the countertop is installed.

•The cutout needs to be made at least 6 inches

from the edges of the countertop.

•If mounting in the countertop above a drawer,

consideration must be given to the depth of the
control mounting assembly.

•A 30 ft. wire cord is provided. Careful consideration

must be given to the location of the remotely
mounted control.

•It is recommended that the 4-wire cord be routed

through 1

conduit between the insert sleeve and

the remote mounting location.

POWER SUPPLY

IMPORTANT - (Please read carefully)

WARNING:

FOR PERSONAL SAFETY, THIS APPLIANCE

MUST BE PROPERLY GROUNDED.

AVERTISSEMENT :

POUR 

DES RAISONS DE SÉCURITÉ, CET APPAREIL

DOIT ÊTRE CORRECTEMENT MIS À LA TERRE.

Remove house fuse or open circuit breaker before
beginning installation.

Do not use an extension cord or adapter plug with 
this appliance. Follow National electrical codes or
prevailing local codes and ordinances. 

Electrical Supply

This vent hood must be supplied with 120V, 60Hz, 
and connected to an individual, properly grounded
branch circuit, and protected by a 15 or 20 amp 
circuit breaker or time delay fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above

requirements, call a licensed electrician before 
proceeding.

• Route house wiring as close to the installation

location as possible, in the ceiling or back wall.

• Connect the hood wiring to the house wiring in 

accordance with local codes.

• House wiring must extend to 45

minimum from

bottom of cabinet in order to make connection to
hood wiring.

Grounding Instructions

The grounding conductor must be connected to 
a grounded metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.

WARNING:

The improper 

connection of the equipment-grounding 
conductor can result in a risk of electric

shock. Check with a qualified electrician or service
representative if you are in doubt whether the
appliance is properly grounded.

AVERTISSEMENT :

Le mauvais branchement du fil de mise 
à la terre peut causer un choc électrique.

En cas de doute, consultez un électricien qualifié 
ou un technicien pour déterminer si l’appareil est 
à la terre.

8

Содержание Monogram ZVC30LSS

Страница 1: ...Installation Instructions 30 36 and 48 Custom Hood Insert ZVC30LSS ZVC36LSS ZVC48LSS 49 80415 12 06 JR...

Страница 2: ...ation and Air Conditioning Engineers ASHRAE and the local code authorities C When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities D Ducted fans must...

Страница 3: ...rries Jubilee Peppercorn Beef Flamb C Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter D Use proper pan size Always use cookware appropriate for the size o...

Страница 4: ...mper Plate 19 Step 5 Install Blower Motor 20 Step 6 Connect Wiring Harness 20 Step 7 Install Filters 21 Step 8 Finalize Installation 21 PRODUCT CLEARANCES The vent hood and liner assembly must be inst...

Страница 5: ...er is shipped with each hood insert This non combustible liner protects the underside of the canopy Custom Liner If you are not using the supplied liner you may construct a custom non combustible line...

Страница 6: ...er is shipped with each hood insert This non combustible liner protects the underside of the canopy Custom Liner If you are not using the supplied liner you may construct a custom non combustible line...

Страница 7: ...the underside of the canopy Custom Liner If you are not using the supplied liner you may construct a custom non combustible liner Use the supplied liner as a template The opening must be 38 3 4 W x 1...

Страница 8: ...of the control mounting assembly A 30 ft wire cord is provided Careful consideration must be given to the location of the remotely mounted control It is recommended that the 4 wire cord be routed thro...

Страница 9: ...Round Duct 9 Advance Planning Total Equivalent Quantity Equivalent Duct Piece Dimensions Length Used Length Round 1 ft straight per foot length 3 1 4 x 12 1 ft 3 1 4 x 24 per foot straight length 8 ro...

Страница 10: ...ve the liner foam and cardboard 3 Remove the tape securing the filters to the insert sleeve lift the tabs and remove the filters 4 Unscrew the 5 nuts securing the damper vent plate assembly and remove...

Страница 11: ...nset hood while unpacking parts Blower motor Models ZVC30LSS and ZVC36LSS Insert sleeve Filters 2 wing nuts with lock washers for blower motor NOTE To be used on custom hood when controls are remotely...

Страница 12: ...p to the ceiling On the ceiling measure 5 1 2 from the back wall to the centerline of an 8 1 2 hole Wall Ducting If ductwork will vent to the rear Use a level to draw a centerline straight up to the c...

Страница 13: ...sleeve must be centered with the insert sleeve The insert sleeve should extend beyond the front and rear edge of the cooking appliance The insert sleeve in the ceiling must be centered left to right o...

Страница 14: ...alled in a backsplash or countertop A cover plate is provided to cover the opening in the hood when the control is removed A 30 ft length of 4 wire cord is supplied to accommodate most installations B...

Страница 15: ...the control with the 2 mounting plate screws 4 Pull the 4 wire cord through the opening in the wall the wall bracket and the back of the mounting bracket NOTE Use provided cable or cable designated b...

Страница 16: ...rame the cutout opening to fit the liner NOTE The opening support must be 3 4 thick wood to accept the liner installation screws 2 Slide the liner up and into the opening until flush with bottom edges...

Страница 17: ...tre maison est en aluminium assurez vous d utiliser un compos anti oxydant approuv et des raccords aluminium cuivre 1 Place insert sleeve on padded yet stable surface below cutout can use flattened ca...

Страница 18: ...t to exhaust opening of insert sleeve and seal with aluminum tape NOTE House duct should drop to 11 1 2 above bottom edge of insert sleeve or the bottom of the 3 4 cabinet base 5 Tape the 4 washers in...

Страница 19: ...embly and rotate so that vent side is up and bracket is located on left as you stand facing hood 2 Insert damper plate assembly into insert sleeve and carefully align with 8 house duct 3 Secure damper...

Страница 20: ...While holding blower motor in place lift right side so that blower motor bolt holes align with bolts protruding from damper plate assembly and secure with lock washers and wing nuts hand tighten STEP...

Страница 21: ...While maintaining slight backward pressure on filter open clip and press into place with two hands 3 To remove support filter with one hand while pulling filter clip down with the other STEP 8 FINALIZ...

Страница 22: ...22 Notes...

Страница 23: ...23 Notes...

Страница 24: ...service in your area call 1 800 444 1845 Note Product improvement is a continuing endeavor at General Electric Therefore materials appearance and specifications are subject to change without notice GE...

Отзывы: