Initial Setup
2-23
April 2004
Table 2-5: Measurement Modes and Units for the Series 1
Selected
Meas. Mode
Description of Units
Displayed
Meas. Mode
Displayed
Units
Oxygen
O
2
%= Percent Oxygen default Oxygen
%
O
2
/ppM = Parts Per Million
Oxygen
ppm
v
O
2
/ppB = Parts Per Billion
Oxygen
ppb
v
O
2
/µA = Microamps (Diagnostic Mode)
Oxygen
µA
O
2
/DVM = Digital Voltmeter (Diagnostic Mode)
Oxygen DVM
VDC
Hygrometry
DP/°C = Dew/Frost Point default
Dew Point
°C
DP/°F = Dew/Frost Point °F
Dew Point
°F
DP/K = Dew/Frost Point K (Kelvin)
Dew Point
K
%R.H. = Relative Humidity
Rel. Humidity
%
H/ppMv = Parts per Million of Water by Volume
H
2
O
ppm
v
H/ppMw = Parts per Million of Water by Weight (for liquids only)
H
2
O
ppm
w
H/ppBv = Parts per Billion of Water by Volume
H
2
O
ppb
v
MCF/IG = Pounds of Water per Million Std. Cubic Feet in Ideal Gas
H
2
O/MMSCF NG
lbs
MCF/NG = Pounds of Water per Million Std. Cubic Feet in Natural Gas
H
2
O/MMSCF NG
lbs
ppMv/NG = Parts Per Million by Volume in Natural Gas
H
2
O (Nat. Gas)
ppm
v
mmHg = Vapor Pressure
Vapor Pressure
mmHg
Pas = Vapor Pressure
Vapor Pressure
Pas
MH = MH* (Diagnostic Mode)
H
2
O
MH
H/DVM = Digital Voltmeter (Diagnostic Mode)
Moisture DVM
VDC
FH = FH* (Diagnostic Mode)
MIS Probe
FH
Temperature
T/°C = Degrees Celsius default
Temperature
°C
T/°F = Degrees Fahrenheit
Temperature
°F
T/K = Kelvin
Temperature
K
T/DVM = Digital Voltmeter (Diagnostic Mode)
Temp DVM
VDC
Pressure
PSIg = Pounds per Square Inch Gauge default
Pressure
PSIg
Bars = Bars
Pressure
Bars
mbs = Millibars
Pressure
mbs
mm/Hg = Millimeters of Mercury
Pressure
mmHg
Pa(g) = Pascal, gauge
Pressure
Pas
kPas(g) = KiloPascal, gauge
Pressure
kPas
P/mV = Pressure in millivolts
Pressure
mV
P/DVM = Digital Voltmeter (Diagnostic Mode)
Pressure DVM
VDC
FP = FP** (Diagnostic Mode)
MIS Probe
FP
Auxiliary 1
Aux1/V = Volts default
Aux1
VDC
Aux1/I = Milliamps
Aux1
mA
Aux1/User = Function (Displays Aux Label)
Aux1 (Aux Label)
none
Auxiliary 2
Aux2/V = Volts default
AuxX
VDC
Aux2/I = Milliamps
Aux2
mA
Aux2/User = Function (Displays Aux Label)
Aux2 (Aux Label)
none
Volt Reference
Vref = Volts default (Diagnostic Mode)
Voltage Reference
VDC
Signal Ground
User
Vgnd = Volts default (Diagnostic Mode)
Signal Ground
VDC
*The MH and FH values are the moisture sensors’ response values and are the values that are recorded during calibration.
**The FP value is the MIS Probe’s response value for pressure and is the value recorded during calibration.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание Moisture Image 1 Series
Страница 8: ...Chapter 1 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 52: ...Chapter 2 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 80: ...Chapter 3 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 96: ...Appendix A Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...