13
PTZ receiver preset position programming
If a PTZ receiver or a KTA-12 series PTZ dome is equipped for preset camera positioning (P option), the
receiver can store 10 preset positions in its nonvolatile memory. You can call each preset position individually
and include each in a preset tour (camera automatically pans, tilts, zooms, and focuses through a series of
preset positions).
To program presets, complete the steps in
System component configuration
2
at the
component programming selection menu (
on page 10), then do the following (for all cameras):
on page 11 to access the receiver site selection display.
2. At the receiver setup display (
page 11), press
2
to begin receiver setup.
3. In the receiver site selection menu
), use the numerical keys to select
the PTZ receiver site to be programmed. The
next display will appear.
Figure 30. Receiver site selection display
4. At the receiver setup display (
press
2
. The next display will appear.
5. Use the PTZ and focus keys to move the
camera to the desired position.
Figure 31. Receiver setup menu display
6. At the preset position display (
assign a preset number (one or two digits
depending on the receiver type and largest
preset number) using one of these methods:
a. If the position
won’t
be included in the
preset tour, enter the preset number. A
tone will sound to acknowledge that the
position has been entered, and the
display will return to
b. If the position
will
be included in the
preset tour, enter the preset number and
hold the last digit until a tone sounds.
The display in
will appear.
Figure 32. Preset position display
7. At the dwell time display (
), enter
the amount of time the camera should remain
at the position (1 to 31 seconds). The display
will return to
to allow you to enter
the next position.
8. Repeat the previous two steps for each
additional preset position. When you are
done, press
Seq
to exit to the receiver site
selection menu (
Figure 33. Preset dwell time display
ENTER RECEIVER SITE
NUMBER 000 SEQ=EXIT
1=SETUP 2=PRESETS
SEQ=EXIT
CAM 000 POSITION? - -
(00-63) SEQ=EXIT
CAM 000 DWELL --
(01-31 SEC) SEQ=EXIT