8
31-2000792 Rev. 0
Installation Instructions
1
ADJUST PRESSURE REGULATOR
FROM NATURAL GAS TO LP
(Cont.)
D.
Remove the retainer from the cap.
E.
Turn the retainer over so LP is showing on the
bottom of the retainer.
F.
Return the retainer inside the cap.
G.
Replace the cap on the regulator.
H.
Replace the Regulator Cover Plate using the 2
screws that held it originally.
1
ADJUST PRESSURE REGULATOR
FROM NATURAL GAS TO LP
A.
Remove the Regulator Cover Plate at the back of
the storage drawer area by removing 2 screws.
B.
Locate the regulator.
C.
Unscrew the cap.
Fig. 11
MAKE THE LP GAS CONVERSION
WARNING
If you are using LP (bottled) gas,
all the adjustments described below must be made
before you make any burner adjustments or use
the oven.
WARNING
This conversion must be
performed by a qualified installer or gas supplier
in accordance with the manufacturer’s instructions
and all codes and requirements of the authority
having jurisdiction. Failure to follow instructions
could result in serious injury or property damage.
The qualified agency performing this work
assumes responsibility for the conversion.
NOTE:
Disconnect all electrical power and turn off the
gas supply at the shut-off valve before beginning the
conversion.
NAT.
l..P.
Cap
Gasket
Spring
Retainer
LP
Nat
Fig. 12
2
ADJUST BURNER ORIFICE FROM
NATURAL TO LP GAS
CAUTION
The adjustments in the next
column must be made before turning on the
burners. Failure to do so could result in serious
injury due to high flames and toxic fumes.
Your Broil burner is located in the upper portion of
the oven and is easilly accessible.
To access your Bake burner follow the steps
below:
A.
Open the oven door.
B.
Remove the oven bottom.
C.
Remove 4 screws holding the oven baffle (flame
VSUHDGHU
D.
Remove the orifice fitting cover.
Oven Bottom
Burner Baffle
Fig. 13
Air Shutter
Orifice
Fitting
Cover
Air Shutter
Screw
Fig. 14
FLEXIBLE HOOK-UP
Pressure Regulator
with Built-In Shut-Off
Valve
Adaptor
Flexible
Connection
Regulator
Cover Plate