BASIC OPERATION AND FEATURES
SX TRANSISTOR CONTROL
Page
13
November 2002
The third speed is obtained by closing SL3 (P20) to control negative. SL3 is adjusted using the Handset and Function 13 similar to
SL1.
If more than one Speed Limit is activated, the selected speed with the highest motor volts will override the low motor volt speed.
The current limit circuit is adjustable and operates the same as the traction current limit.
The controlled acceleration circuit is adjustable and operates the same as the traction circuit. Adjustment range is from 0.1 to
5.5 seconds.
The Battery Discharge Indicator (BDI) interrupt will disable the hydraulic controller if the connection at P10 loses the 12 volt
signal from the traction control. BDI interrupt can be disabled by Function 17 using the Handset. Select card type with or without
BDI function.