DIAGNOSTIC STATUS CODES
TRANSISTOR PUMP CONTROL
Page
49
Section 4.6 Pump Control Codes
PUMP
STATUS CODE
DESCRIPTION OF STATUS
CAUSE OF STATUS INDICATION
-117
“Card Type” selection is invalid.
This status code will be displayed when the card type
selection value is set to an invalid number.
MEMORY RECALL
NO
CORRECTIVE ACTIONS
TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Pump
Controller
SYMPTOM
Control will not operate.
POSSIBLE CAUSE
Invalid card type selection.
•
Review function 17 in the Handset
Instruction sheets. Adjust and set
card type value as instructed by OEM
service manual.
NO
GRAPHIC
FOR THIS
STATUS CODE
PUMP
STATUS CODE
DESCRIPTION OF STATUS
CAUSE OF STATUS INDICATION
-127
Control logic card power supply is less
than 10 VDC.
This status code is displayed when the logic card
power supply is less than 10 volts.
MEMORY RECALL
YES
CORRECTIVE ACTIONS
TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Pump
Controller
SYMPTOM
Control will not operate.
POSSIBLE CAUSE
Discharged Battery
•
Check battery to insure proper state of
charge.
Loose connection at P1.
•
Insure that the wire connection at P1 is
tight.
Defective logic card
•
Replace control.
AR
M
A
T
U
R
E
*
FI
E
L
D
PUMP CONT
RO
L
P
L
UG PL-
2
STATUS CODE 93 INPUT
STATUS CODE 93 INPUT
STATUS CODE 94 INPUT
STATUS CODE 95 INPUT
STATUS CODE 91 INPUT
STATUS CODE 90 INPUT
STATUS CODE 95 INPUT
STATUS CODE 94 INPUT
STATUS CODE 92 INPUT
BRUSH WEAR OUTPUT
OVER TEMP OUTPUT
P2
P1
P3
P4
P5
P6
P8
P9
P15
P16
P11
P13
P14
P18
P12
P19
P20
P21
*
*
*
PUMP CONTROL TEMP
SP
EED 2
SP
EED 1
*
SPE
ED 3
*
S
PEE
D 4
P7
POWER CONNECTION
SUPPLIED BY CUSTOMER
*
PUMP CONTROL
POWER CONNECTION
P
A1
A2
N
A1
A2
A2
A1
N
KEY SW.
BATT (-)
BATT (+)
FU
2
P
LINE
CONTACTOR
FU
4
L
P17
ACCEL POT INPUT
*
*
*
*
September 2004