ADJUSTABLE FEATURES
TRANSISTOR PUMP CONTROLS
Page
70
This function is not applicable to this type of control and
should not be adjusted.
Warning: These setting must be changed by authorized
personnel only, following instructions supplied by the
manufacturer. Card type selection must be made within
the capabilities of the TRANSISTOR control panel used
and the supporting electro-mechanical devices. Failure
to comply with proper application standards could result
in mis-operation or damage to the control and/or motors.
FUNCTION 16
SPEED / TORQUE COMPENSATION
(Push CONT 1)
This function is used to stabilize pump speed at heavy
loads. The voltage selected will be added to the motor at
each 100 amp increment starting at the value set in
Function 2. The voltage compensation selected will be
added in increments of 0.375 volts until the entire voltage is
added. For example, a setting of 2 will be added in 30 steps
of 0.375 volts each whereas, a setting of 4 will be added in
15 steps of 0.375 volts each.
FUNCTION 28:
FAULT COUNT POINTER
(Push CONT 13)
This register contains the location of the last stored status
code recorded of the 16 stored status codes. These stored
status codes have caused a PMT controller shutdown
and/or disruption of normal vehicle operation.
SPEED / TORQUE
COMPENSATION TABLE
To determine which stored status code was the last one
recorded, read the number stored in Function 28. Using the
Memory Map
(See Section 8.1) for your logic card, match
the
“stored status code pointer number”
(the number
shown in
(bold italics)
in the HS (Handset) number column)
on the memory map, with the number obtained from
Function 28. This will be the last stored status code
recorded.
SETTING
VOLTAGE
DROP
SETTING
VOLTAGE
DROP
2 11.44 17 1.34
3 7.60 18 1.27
4 5.72 19 1.20
5 4.57 20 1.14
6 3.81 21 1.09
7 3.27 22 1.04
8 2.86 23 0.99
9 2.54 24 0.95
10 2.28 25 0.91
11 2.08 26 0.88
12 1.90 27 0.85
13 1.76 28 0.82
14 1.63 29 0.79
15 1.52 30 0.76
16 1.43 31 0.74
Note: When scrolling the stored status code register, the
register always starts at status code 1 and scrolls to
status code 16. Instructions for scrolling the register are
in Section 6.3.2 of this instruction booklet.
FUNCTION 17
CARD TYPE SELECTION
(Push CONT 2)
FUNCTION 48
MODE 1 - CONTROLLED ACCELERATION
(Push CONT 1)
This function should be set in accordance with the control
type in use in the vehicle:
This function allows for the adjustment of the rate of time it
takes for the control to accelerate to 96% applied battery
voltage to the motor on hard acceleration.
Function Setting
Std C/L BDI Lockout
High C/L BDI Lockout
54 to 62
63 to 71
Range
0.1 to 22.0 seconds
Setting
0 to 255
Resolution
0.084 seconds per set unit
BDI Lockout means that the BDI signal from the traction
control must be present in order for the pump control to
operate. This control will stop operation when the battery
state of charge reaches 10%.
Example: Setting of 20 = 1.8 seconds C/A
FUNCTION 49
MODE 1 – LIFT 1 SPEED LIMIT (SL2)
(Push CONT 2)
Settings for these functions should be made in between the
values shown.
September 2004
Note: The following functions have function numbers
larger than the numbers on the Handset keyboard. To
access these functions, push the CONT key and the
number shown in the following instructions at the same