ADJUSTABLE FEATURES
SX TRANSISTOR CONTROLS
Page 65
January 1999
FUNCTION 57
MODE 3 REGEN CURRENT LIMIT
(Push
CONT
10)
Same as Function 49.
This FIELD WEAKENING START takes effect when the
Mode 3 settings are called for by the Interactive Dash
Display.
FUNCTION 58
MODE 3 BRAKE PEDAL REGEN
(Push
CONT
11)
Same as Function 50.
This MINIMUM FIELD CURRENT takes effect when the
Mode 3 settings are called for by the Interactive Dash
Display.
FUNCTION 59
MODE 3 SPEED LIMIT 2
(Push
CONT
12)
Same as Function 51.
This RATIO takes effect when the Mode 3 settings are
called for by the Interactive Dash Display.
FUNCTION 60
MODE 4 ARMATURE CONTROLLED
ACCELERATION AND 1A TIME
(Push
CONT
13)
Same as Function 48.
This C/A AND 1A TIME takes effect when the Mode 4
settings are called for by the Interactive Dash Display.
FUNCTION 61
MODE 4 REGEN CURRENT LIMIT
(Push
CONT
14)
Same as Function 49.
This FIELD WEAKENING START takes effect when the
Mode 4 settings are called for by the Interactive Dash
Display.
FUNCTION 62
MODE 4 BRAKE PEDAL REGEN
(Push
CONT
15)
Same as Function 50.
This MINIMUM FIELD CURRENT takes effect when the
Mode 4 settings are called for by the Interactive Dash
Display.
FUNCTION 63
MODE 4 SPEED LIMIT 2
(Push
CONT
16)
Same as Function 51.
This RATIO takes effect when the Mode 4 settings are
called for by the Interactive Dash Display.