l. rEPlaCEMEnT ParT liST anD
PrOcedUres
replacement Procedures
a. SySTEM rEPlaCEMEnT
A System may require replacement for one of three possible
reasons. The need for a System to be replaced must
be recommended and confirmed by a Qualified Service
Technician. Possible reasons for replacement include: 1)
The System (during Commissioning or Annual Maintenance)
fails the Integrity Test. 2) The TMP result during Annual
Maintenance after the Membrane Cleaning is too high
(greater than 20 psi TMP) indicating there is too much
fouling of the membrane and the household water flow rate
is too low. The water quality entering the System will greatly
influence how fast the System will foul. 3) The System is
damaged on delivery and is not suitable for installation.
Some water may still remain in the System. Plug the
Inlet, Outlet, and Drain ports immediately once the
pipe assemblies have been removed.
WARNING!
replacement instructions for UfC100, Uf100, Uf100
with Surface Water Option Kit Series only:
1.
Close the Inlet and Bypass Valves.
2.
Depressurize the System by turning on a tap until
no water flows out from the tap.
3.
Drain the System by activating a Manual Flush
sequence. Refer to the instructions in the
Controller functions
section under
E. inSTallaTiOn inSTrUCTiOnS
on how to
perform a Manual Flush sequence.
4.
Turn off the tap and close the Outlet Valve.
5.
Unplug the Controller.
6.
Remove the System from the existing plumbing at
the Inlet and Outlet Stainless Steel Flex Hoses.
7.
Disconnect the drain line.
replacement instructions for UfC 207, Uf 207, UfC 209,
Uf 209, UfC 211 and Uf 211 Series only:
1.
Close the Inlet and Bypass Valves.
2.
Depressurize the System by turning on a tap until
no water flows out from the tap.
3.
Drain the System by activating a Manual Flush
sequence. Refer to the instructions in the
Controller functions
section under
E. inSTallaTiOn inSTrUCTiOnS
on how to
perform a Manual Flush sequence.
4.
Turn off the tap and close the Outlet Valve.
5.
Unplug the Controller.
6.
Disconnect the Drain Solenoid Valve cable and
the Inlet Solenoid Valve cable (if applicable) at the
Controller. Refer to FIGURE 27.
follow Steps 7 to 16 for Vertical Systems:
8
Remove Controller on the wall.
9
Unbolt the System Base from the floor.
10
If under warranty, the old System must be
completely sealed, packaged and returned to the
factory within 24 hours to avoid internal damage
and allow a cause analysis to be completed.
11
Label the box appropriately as in the table below.
Call the Homespring™ Consumer Products
Customer Service for shipping and handling details
at 1-866-418-7412.
12.
Install and commission the new System according
to the Operations Manual.
7.
Remove the Air Relief Valve, the Inlet pipe
assembly, and the Drain line assemblies from
the System. Removal of the Inlet pipe assembly
may require disconnecting the Inlet line at
multiple places.
8.
Remove all the Inlet, Drain, and Air Relief
Valve plugs from the new System and insert
those plugs into the equivalent ports of the old
System.
Locking
Clip
Locking
Clip
screw
Outlet
pipe as-
sembly
Inlet pipe
assembly
Backpulse
Tank
System
Casing
System
Cap
Drain line
assembly
fiGUrE 58
34
label on System Box
Use only if:
“inTEGriTy”
+ Homespring™
Qualified Technician Number
If the System has failed
the Integrity Test.
“FOUled”
+ Homespring™
Qualified Technician Number
If the System is fouled.
“dAmAged”
- Homespring™
Qualified Technician Number
If the System has
been damaged
during transportation,
warehousing or
installation steps.