3/4”x1/4”

Bushing

3/4” Brass

Tee

Check 

Valve

Mini Ball Valve 

with Plug

Outlet port 

of System 

3/4” MNPT 

Nipple

3/4” poly 

Nipple

Stainless Steel

Flex Hose

3/4” MNPT 

Nipple

Outlet fitting assembly

UF100 with 

optional Surface 

Water Option Kit 

model only

fiGUrE 15 

Metal

Support

Strap

fiGUrE 19 

Fasten

System

to End Cast Iron 

Stand here

Channel

on the System

Attach foam gasket

to concave feature on 

the End Cast Iron Stand

Tab on the 

Middle Cast 

Iron Stand

fiGUrE 18 

Outlet fitting assembly

Mini Ball Valve

with Plug

Inlet/Outlet

Fitting

Stainless Steel 

Flex Hose

For models 

equipped with 

Surface Water 

Option Kit only 

3/4” MNPT

Nipple

Check 

Valve

Outlet port

of System

fiGUrE 17 

inlet fitting assembly

Mini Ball Valve

with Plug

Inlet/Outlet

Fitting

Stainless Steel 

Flex Hose

For models 

equipped with 

Surface Water 

Option Kit only 

Inlet Solenoid

Valve

3/4” MNPT

Nipple

Inlet port of 

System

fiGUrE 16 

7

a

For UFC 207, UF 207, UFC 209, UF 209, UFC  211, 

and UF 211 models, the two Inlet/Outlet Fitting assemblies 

are shipped pre-assembled, with the Mini Ball Valves and 

Plugs already installed. Ensure that the Teflon® tape at both 

threaded ends are in good condition. Assemble the Inlet and 

Outlet Fitting assemblies as shown. 

6

b

7

a

6

a

6

a

 UFC 207, UF 207,  UFC 209, UF 209,  UFC 211, and 

UF 211

models, install the Drain Solenoid Valve (normally 

closed) to the ½” Nipple to the Drain port of the System. 

The  directional  arrow  on  the  Drain  Solenoid  Valve  must 

point in the direction of the water flow (i.e. away from the 

System). Install the Nylon Elbow to the flow exit port of the 

Drain Solenoid Valve.

Horizontally-mounted Systems:

Install the ½” Nipple and the ½” Brass Elbow 

provided in 

the Horizontal Mounting Kit at the Drain port of the System. 

Install the Drain Solenoid Valve to the ½” Brass Elbow 

using another ½” Nipple. 

7

b

For  UFC100,  UF100,  and  UF100  with  optional 

Surface  Water  Option  Kit  models,  connect  the  Drain 

Solenoid Valve (normally closed) to the 3/4” Nipple at the 

Drain port of the System. The directional arrow on the Drain 

Solenoid  Valve  must  point  in  the  direction  of  the  water 

flow (i.e. away from the System). Thread the Nylon Elbow 

to  the  water  flow  exit  port  of  the  Drain  Solenoid  Valve.

7

a

The System Base is not required in this installation. Peel 

off the adhesive backing on the foam gasket supplied in 

the Horizontal Mounting Kit. Attach the foam gasket to the 

concave feature on the End Cast Iron Stand. 

8

 

applicable to Horizontally-mounted Systems 

The directional arrow on the Check Valve must point in the 

direction of the water flow.

The directional arrow on the Check Valve must point in the 

direction of the water flow.

The directional arrow on the Inlet Solenoid Valve must point 

in the direction of the water flow.

Lift  up  and  place  the  System  in  the  Bracket.  Orient  the 

System  to  make  the  Inlet,  Drain,  and  Outlet  ports  facing 

downward.  Ensure  that  the  channel  on  the  back  of  the 

System  locks  into  the  tab  on  the  Middle  Cast  Iron  Stand.

Using two of the 3/8” bolts supplied with the System,  fasten 

the bottom of the System to the cross bar on the End Cast 

Iron Stand. The Middle Cast Iron Stand is attached to the 

Cast  Iron  Cross  Member  by  two  ¼”  bolts  and  lock  nuts.    

Unscrew  the  ¼”  bolt  and  lock  nut  closest  to  the  System. 

Position the semi-circular Metal Support Strap over the Sys

-

tem. Align the holes on the Metal Support Strap with the holes 

on the Middle Cast Iron Stand. Reusing the ¼” bolt and lock nut 

from the last step, fasten one end of the Metal Support Strap to 

the Middle Cast Iron Stand. Use the remaining ¼” bolt and lock 

nut supplied in the Horizontal Mounting Kit to fasten the other 

end of the Metal Support Strap to the Middle Cast Iron Stand.

11

Содержание Homespring UFC 100

Страница 1: ...8 23 G ANNUAL MAINTENANCE Pages 23 24 H WINTERIZATION Pages 25 27 I TROUBLESHOOTING Pages 28 29 J SPECIFICATIONS Pages 30 31 K FAQ Pages 32 33 L REPLACEMENT PART LIST AND PROCEDURES Pages 34 42 Operat...

Страница 2: ...d when installing or servicing the filtration system System Failure to do may result in System damage serious personal in jury death and or property damage Use of non OEM parts will void the manufactu...

Страница 3: ...ion Bypass Procedure 1 Close Inlet and Outlet Valves If ball valves are installed turn the handles perpendicular to the water pipe 2 Open Bypass Valve If ball valve is in stalled turn the handle in li...

Страница 4: ...e system Models with activated carbon filter option certified for cyst reduction may be used on disinfected waters that may contain filterable cysts The UFC 100 UFC 207 UFC 209 and UFC 211 models All...

Страница 5: ...ndard System with the exception of additional parts which must be installed as shown Additional parts include an Inlet Solenoid Valve Check Valve and External Prefilter Awater softener can be placed e...

Страница 6: ...pre assembled System Base Base Controller Transformer 120VAC Stainless Steel Prefilter Two Stainless Steel Flex Hoses Inside the bubble bag 1 Drain Solenoid Valve Normally Closed 1 Nylon Elbow 2 Bras...

Страница 7: ...ne diverted from the main water line is recommended to be installed upstream of the System for all exterior taps pool or hot tub makeup valves and irrigation systems This set up will help prolong the...

Страница 8: ...The vertical spacing required is 36 from the bottom of the bracket If possible install the System at a height convenient for servicing Installation Drill into the concrete floor or block and anchor th...

Страница 9: ...et up align the top mounting hole on the Bracket assembly with the pre drilled hole on the wall stud and secure the Bracket assembly with one 2 anchoring bolt Do not tighten this bolt completely 4b Th...

Страница 10: ...to the local plumbing code in your area The directional arrow on the Inlet Solenoid Valve must point in the direction of the water flow Do not pressurize the Backpulse Tank to greater than 35psi Highe...

Страница 11: ...all the Drain Solenoid Valve to the Brass Elbow using another Nipple 7b For UFC100 UF100 and UF100 with optional Surface Water Option Kit models connect the Drain Solenoid Valve normally closed to the...

Страница 12: ...n in this manual to install the External Prefilter Connect the Stain less Steel Flex Hose on the Inlet Fitting assembly to the External Prefilter Once finished connect the External Prefilter to the MN...

Страница 13: ...n the connection Take care not to cross thread this connection Fibre Chamber Air Vent Assembly 3 Complete Pre filter Chamber Air Vent Assembly as shown in FIGURE 24a A second Air Relief Valve is provi...

Страница 14: ...A dedicated trap drain must be installed by a li censed plumber due to the complexity of venting sizing and trap installation Improper venting and trap installation can lead to sewer gases backing up...

Страница 15: ...e Controller to the wall by tightening the two screws Use the plastic anchors if necessary 2 Ensure the transformer is not plugged into the electrical receptacle Connect the power supply cable from th...

Страница 16: ...f power failure and will not activate the flushing and draining sequences NOTE Once the Controller is set the Controller will remember the Start Time Program Number and Flush Drain Interval settings i...

Страница 17: ...ncrease frequency of flush drain cycle if the System TMP rises too quickly Increasing the number of Flush Drain cycles per day will prolong the life of the System however morewaterwillbeusedforsystemc...

Страница 18: ...ing the Cap Wrench For models with a Stainless Steel Prefilter a Carbon Pre filter may be purchased separately if desired The Surface Water Option Kit is purchased separately from the System except fo...

Страница 19: ...Controller Func tions section under E INSTALLATION INSTRUCTIONS on how to perform a Manual Flush sequence Following the Manual Flush open a cold water tap that is downstream of the System Allow water...

Страница 20: ...e the flushing is complete open the Outlet Valve and a nearby COLD water tap to flush most of the chlorine from the System Run the tap fully open for at least 10 minutes Further flushing must be perfo...

Страница 21: ...ity Tester into a power supply Press any button twice to turn it on Press the scroll keys until the screen displays Integrity Test Press ENTER and use the scroll keys to choose either Vertical or Hori...

Страница 22: ...cause is a leak in the System from hoses connections or valves Be sure that all connections are tight before beginning the test and the Inlet and Outlet Valves are closed Leaky valves and loose connec...

Страница 23: ...the System to protect your hands At the end of the procedure wash your hands thoroughly with soap and water Do not reuse the gloves Dispose of the gloves in the garbage Complete Paperwork The followi...

Страница 24: ...Installation section under E INSTALLATION INSTRUCTIONS to install a new External Prefilter cartridge 4 Be careful to avoid MC1 cleaning agent coming in contact with skin or clothing Wash the mixing co...

Страница 25: ...by installing a MNPT PVC plug H WINTERIZATION PROCEDURE 4 If an External Prefilter has been installed open the Mini Ball Valve on the bottom of the housing and allow to drain Press the red button on...

Страница 26: ...Reinstall the plug into the Outlet Stainless Steel Flex Hose Fill with approximately 3 US gal 12litres of 58o F 50o C propylene glycol based plumbing antifreeze The UFC 207 UF 207 UFC 209 UF 209 UFC...

Страница 27: ...nlet Valve and Outlet Valve Use the Controller to depressurize the System Use Pressure Gauges to ensure no pressure remains in the System Open Note If the winterization spring start up is combined wit...

Страница 28: ...STALLATION INSTRUCTIONS initiate a manual flush and verify Drain Solenoid Valve is working Replace valve if necessary Water does not flow through System Black cap on Air Vent must be backed off by 1 5...

Страница 29: ...heard from the Drain Solenoid Valve Replace valve if necessary Check connections are installed correctly and transformer is plugged in Inlet Solenoid Valve Doesn t close to allow System to drain On th...

Страница 30: ...8 4 73 7 litres 7 5 19 5 gal 28 4 73 7 litres 7 5 19 5 gal 28 4 73 7 litres 7 5 19 5 gal 28 4 73 7 litres System efficiency 92 96 92 96 94 97 87 94 4 92 96 4 94 97 4 Controller voltage 24 VAC 24 VAC 2...

Страница 31: ...litres 15 gal 56 7 litres Program 3 4 flush backpulse cycles 2 flush backpulse cycles 1 drain cycle 2 flush backpulse cycles 1 drain cycle Estimated water use US gallons 20 gal 75 6 litres 13 5 gal 5...

Страница 32: ...re removed as the water passes from the outside of the Prefilter to the inside 2 The prefiltered water then passes down into the System to the membrane chamber 3 In the membrane chamber the water trav...

Страница 33: ...he membrane and remain in your water This includes calcium and magnesium which contribute to your hard water and other dissolved solids like essential minerials and flouride How long does the automati...

Страница 34: ...ressurize the System by turning on a tap until no water flows out from the tap 3 Drain the System by activating a Manual Flush sequence Refer to the instructions in the Controller Functions section un...

Страница 35: ...bythehand 33 Reattach the Locking Clip Air Relief Valve Inlet Outlet Drain pipe assemblies Internal Prefilter System Cap External Prefilter if applicable and the Air Vent Assembly Reattach the Metal S...

Страница 36: ...carefully remove and dispose of the Internal Prefilter D EXTERNAL PREFILTER REPLACEMENT Depending on the water quality the External Prefilter may need to be washed or replaced prior to the Annual Mai...

Страница 37: ...37...

Страница 38: ...UFC100 UF100 UF100 with Surface Water Option Kit Series 2 1 3 4 7 6 5 9 8 10 11 15 16 17 14 4 25 26 12 FIGURE 60 18 19 23 20 21 22 13 24 38...

Страница 39: ...rvice Tag X X X 14 23029 Cap Wrench X X X Sub Assembly Kits 15 23117 Installation Sub Assembly Kit Inlet Pipe Assembly Kit Outlet Pipe Assembly Kit Drain Pipe Assembly Kit Air Relief Valve X X X 16 23...

Страница 40: ...1 3 2 6 5 8 8 9 14 15 16 17 23 19 20 18 25 30 31 32 33 UFC 207 UF 207 UFC 209 UF 209 UFC 211 and UF 211 Series 21 24 FIGURE 61 11 10 22 27 26 28 29 7 4 40 13 12...

Страница 41: ...153 System Cap Short X 15 23154 System Cap Long X 16 23214 Loading O ring X X 17 23260 Kit Locking Clip with mounting screw X X 18 23159 System Base X X 19 23172 Thimble Filter X X 20 23221 Plug 1 4 N...

Страница 42: ...3060 Wall Bracket 8 23061 1 to Reducing Bushing 9 23183 Mini Ball Valve Plug 10 23062 Mini Ball Valve 11 23104 Housing Wrench External Prefilter Service Testing Kit Parts 12 23104 Housing Wrench Exter...

Страница 43: ......

Отзывы: