GE Homespring UFC 100 Скачать руководство пользователя страница 32

K. frEQUEnTly aSKED 

QUESTiOnS (faQ)

 What does the System do?

This System has been tested to significantly physically 

block pathogens including bacteria, viruses and cysts from 

your water. The pore size on the surface of the ultrafilter 

membrane is 0.02 microns nominal. The System has been 

certified by the National Sanitation Foundation (NSF) 

for NSF 42 and 53 (aesthetic and health claims) for the 

removal of Cysts, Turbidity, Particulates and Chlorine. 

Further test results from BioVir Laboratories in California 

include bacteria and virus reduction performance. Please 

refer to 

C. CErTifiCaTiOn

 for more information.

W h e r e   s h o u l d   t h e   S y s t e m   b e   i n s t a l l e d ?

The System is installed inside the home at the point where 

water enters the house so that filtered water is provided from 

every tap.  In order to allow only indoor water to be treated, a 

dedicated line should be installed from the inlet of the System 

to all external taps for pool or hot tub makeup valves and 

irrigation systems.   Reducing the volume of water filtered 

will assist in prolonging the life of the System membrane.  

For  Spacing  Requirements  refer  to 

J.  SPECifiCaTiOnS.

D o e s   t h e   S y s t e m   r e q u i r e   e l e c t r i c i t y ?

In  most  installations,  the  System  runs  on  existing 

household water pressure provided that a minimum pressure 

of  30  psi  is  met.    Unless  electricity  is  required  for  pump 

operation,  the  System  will  continue  to  filter  water  during 

a  power  failure  and  Controller  settings  will  be  saved  by 

battery  backup  power.  The  Controller  must  be  plugged 

into  a  standard  120V  outlet  to  provide  power    to  operate 

the  solenoid  valves  that  initiate  flushing  of  the  System.  If 

electrical power is not available, the System will not conduct 

automatic  cleaning  and  the  rate  of  fouling  will  increase.

How does the System work?

Filtering  - 

When  a  household  water  fixture  is  turned  on, 

the water pressure forces unfiltered water into the Prefilter 

Housing.

(1).

  Larger particles (and chlorine when using the Carbon 

Prefilter) are removed as the water passes from the outside 

of the Prefilter to the inside.  

(2).

  The prefiltered water then passes down into the System 

to the membrane chamber.

(3).  

In the membrane  chamber, the water travels through 

membrane  pores  from  the  outside  of  the  hollow  fibre 

membrane to the inside, leaving behind unwanted particles 

such as bacteria, parasites and certain viruses.

(4)

.  The filtered water then travels through the household 

piping, to the household fixture that is being used.

automatic Cleaning Cycle 

- The System uses two methods 

to  clean  its  membrane:  a)  flushing  and  b)  draining.  The 

Controller  automatically  executes  a  cleaning  sequence 

consisting  of  a  number  of  flushes  and  drains  to  clean 

the  membrane.  For  Systems  equipped  with  a  Base  or 

Advanced  Controller,  System  cleaning  is  performed  daily. 

For  Systems  equipped  with  an Advanced  Plus  Controller, 

System cleaning may be performed multiple times per day, 

up  to  24  times.  For  choices  of  cleaning  sequences  and 

intervals, refer to the  

controller settings 

section under

 e. 

inSTallaTiOn inSTrUCTiOnS. 

Water pressure inside the 

dwelling will be significantly reduced during System cleaning.

Flushing

: Flushing includes a Front-flush

 and a Back-

flush

. Systems that are installed in municipal, cistern, or 

ground water sources may use the flushing method to 

control the fouling rate of the membrane. 

(5)

.  

Front-flush

 - The Controller opens the Drain Solenoid 

Valve. The water supply line pressure causes an inrush 

of water into the System, scouring the surfaces of the 

membrane and expelling impurities through the drain.

(6).

   

Back-flush

 - At the same time, the air bladder inside 

the Backpulse Tank expands rapidly, pushing clean water  

out of the membrane surfaces from the hollow cores. This 

action dislodges and pushes out impurities trapped inside 

the membrane pores. Impurities are then expelled out of 

the System through the drain port.

Draining:

  Systems  that  are  installed  in  surface  water 

sources  must  use  the  draining  method  in  addition  to 

the  flushing  method  to  control  the  fouling  rate  of  the 

membrane.  During  draining,  the  Controller  closes  the 

Inlet  Solenoid  Valve  and  opens  the  Drain  Solenoid  Valve, 

allowing water to be completely drained out of the System. 

32

Содержание Homespring UFC 100

Страница 1: ...8 23 G ANNUAL MAINTENANCE Pages 23 24 H WINTERIZATION Pages 25 27 I TROUBLESHOOTING Pages 28 29 J SPECIFICATIONS Pages 30 31 K FAQ Pages 32 33 L REPLACEMENT PART LIST AND PROCEDURES Pages 34 42 Operat...

Страница 2: ...d when installing or servicing the filtration system System Failure to do may result in System damage serious personal in jury death and or property damage Use of non OEM parts will void the manufactu...

Страница 3: ...ion Bypass Procedure 1 Close Inlet and Outlet Valves If ball valves are installed turn the handles perpendicular to the water pipe 2 Open Bypass Valve If ball valve is in stalled turn the handle in li...

Страница 4: ...e system Models with activated carbon filter option certified for cyst reduction may be used on disinfected waters that may contain filterable cysts The UFC 100 UFC 207 UFC 209 and UFC 211 models All...

Страница 5: ...ndard System with the exception of additional parts which must be installed as shown Additional parts include an Inlet Solenoid Valve Check Valve and External Prefilter Awater softener can be placed e...

Страница 6: ...pre assembled System Base Base Controller Transformer 120VAC Stainless Steel Prefilter Two Stainless Steel Flex Hoses Inside the bubble bag 1 Drain Solenoid Valve Normally Closed 1 Nylon Elbow 2 Bras...

Страница 7: ...ne diverted from the main water line is recommended to be installed upstream of the System for all exterior taps pool or hot tub makeup valves and irrigation systems This set up will help prolong the...

Страница 8: ...The vertical spacing required is 36 from the bottom of the bracket If possible install the System at a height convenient for servicing Installation Drill into the concrete floor or block and anchor th...

Страница 9: ...et up align the top mounting hole on the Bracket assembly with the pre drilled hole on the wall stud and secure the Bracket assembly with one 2 anchoring bolt Do not tighten this bolt completely 4b Th...

Страница 10: ...to the local plumbing code in your area The directional arrow on the Inlet Solenoid Valve must point in the direction of the water flow Do not pressurize the Backpulse Tank to greater than 35psi Highe...

Страница 11: ...all the Drain Solenoid Valve to the Brass Elbow using another Nipple 7b For UFC100 UF100 and UF100 with optional Surface Water Option Kit models connect the Drain Solenoid Valve normally closed to the...

Страница 12: ...n in this manual to install the External Prefilter Connect the Stain less Steel Flex Hose on the Inlet Fitting assembly to the External Prefilter Once finished connect the External Prefilter to the MN...

Страница 13: ...n the connection Take care not to cross thread this connection Fibre Chamber Air Vent Assembly 3 Complete Pre filter Chamber Air Vent Assembly as shown in FIGURE 24a A second Air Relief Valve is provi...

Страница 14: ...A dedicated trap drain must be installed by a li censed plumber due to the complexity of venting sizing and trap installation Improper venting and trap installation can lead to sewer gases backing up...

Страница 15: ...e Controller to the wall by tightening the two screws Use the plastic anchors if necessary 2 Ensure the transformer is not plugged into the electrical receptacle Connect the power supply cable from th...

Страница 16: ...f power failure and will not activate the flushing and draining sequences NOTE Once the Controller is set the Controller will remember the Start Time Program Number and Flush Drain Interval settings i...

Страница 17: ...ncrease frequency of flush drain cycle if the System TMP rises too quickly Increasing the number of Flush Drain cycles per day will prolong the life of the System however morewaterwillbeusedforsystemc...

Страница 18: ...ing the Cap Wrench For models with a Stainless Steel Prefilter a Carbon Pre filter may be purchased separately if desired The Surface Water Option Kit is purchased separately from the System except fo...

Страница 19: ...Controller Func tions section under E INSTALLATION INSTRUCTIONS on how to perform a Manual Flush sequence Following the Manual Flush open a cold water tap that is downstream of the System Allow water...

Страница 20: ...e the flushing is complete open the Outlet Valve and a nearby COLD water tap to flush most of the chlorine from the System Run the tap fully open for at least 10 minutes Further flushing must be perfo...

Страница 21: ...ity Tester into a power supply Press any button twice to turn it on Press the scroll keys until the screen displays Integrity Test Press ENTER and use the scroll keys to choose either Vertical or Hori...

Страница 22: ...cause is a leak in the System from hoses connections or valves Be sure that all connections are tight before beginning the test and the Inlet and Outlet Valves are closed Leaky valves and loose connec...

Страница 23: ...the System to protect your hands At the end of the procedure wash your hands thoroughly with soap and water Do not reuse the gloves Dispose of the gloves in the garbage Complete Paperwork The followi...

Страница 24: ...Installation section under E INSTALLATION INSTRUCTIONS to install a new External Prefilter cartridge 4 Be careful to avoid MC1 cleaning agent coming in contact with skin or clothing Wash the mixing co...

Страница 25: ...by installing a MNPT PVC plug H WINTERIZATION PROCEDURE 4 If an External Prefilter has been installed open the Mini Ball Valve on the bottom of the housing and allow to drain Press the red button on...

Страница 26: ...Reinstall the plug into the Outlet Stainless Steel Flex Hose Fill with approximately 3 US gal 12litres of 58o F 50o C propylene glycol based plumbing antifreeze The UFC 207 UF 207 UFC 209 UF 209 UFC...

Страница 27: ...nlet Valve and Outlet Valve Use the Controller to depressurize the System Use Pressure Gauges to ensure no pressure remains in the System Open Note If the winterization spring start up is combined wit...

Страница 28: ...STALLATION INSTRUCTIONS initiate a manual flush and verify Drain Solenoid Valve is working Replace valve if necessary Water does not flow through System Black cap on Air Vent must be backed off by 1 5...

Страница 29: ...heard from the Drain Solenoid Valve Replace valve if necessary Check connections are installed correctly and transformer is plugged in Inlet Solenoid Valve Doesn t close to allow System to drain On th...

Страница 30: ...8 4 73 7 litres 7 5 19 5 gal 28 4 73 7 litres 7 5 19 5 gal 28 4 73 7 litres 7 5 19 5 gal 28 4 73 7 litres System efficiency 92 96 92 96 94 97 87 94 4 92 96 4 94 97 4 Controller voltage 24 VAC 24 VAC 2...

Страница 31: ...litres 15 gal 56 7 litres Program 3 4 flush backpulse cycles 2 flush backpulse cycles 1 drain cycle 2 flush backpulse cycles 1 drain cycle Estimated water use US gallons 20 gal 75 6 litres 13 5 gal 5...

Страница 32: ...re removed as the water passes from the outside of the Prefilter to the inside 2 The prefiltered water then passes down into the System to the membrane chamber 3 In the membrane chamber the water trav...

Страница 33: ...he membrane and remain in your water This includes calcium and magnesium which contribute to your hard water and other dissolved solids like essential minerials and flouride How long does the automati...

Страница 34: ...ressurize the System by turning on a tap until no water flows out from the tap 3 Drain the System by activating a Manual Flush sequence Refer to the instructions in the Controller Functions section un...

Страница 35: ...bythehand 33 Reattach the Locking Clip Air Relief Valve Inlet Outlet Drain pipe assemblies Internal Prefilter System Cap External Prefilter if applicable and the Air Vent Assembly Reattach the Metal S...

Страница 36: ...carefully remove and dispose of the Internal Prefilter D EXTERNAL PREFILTER REPLACEMENT Depending on the water quality the External Prefilter may need to be washed or replaced prior to the Annual Mai...

Страница 37: ...37...

Страница 38: ...UFC100 UF100 UF100 with Surface Water Option Kit Series 2 1 3 4 7 6 5 9 8 10 11 15 16 17 14 4 25 26 12 FIGURE 60 18 19 23 20 21 22 13 24 38...

Страница 39: ...rvice Tag X X X 14 23029 Cap Wrench X X X Sub Assembly Kits 15 23117 Installation Sub Assembly Kit Inlet Pipe Assembly Kit Outlet Pipe Assembly Kit Drain Pipe Assembly Kit Air Relief Valve X X X 16 23...

Страница 40: ...1 3 2 6 5 8 8 9 14 15 16 17 23 19 20 18 25 30 31 32 33 UFC 207 UF 207 UFC 209 UF 209 UFC 211 and UF 211 Series 21 24 FIGURE 61 11 10 22 27 26 28 29 7 4 40 13 12...

Страница 41: ...153 System Cap Short X 15 23154 System Cap Long X 16 23214 Loading O ring X X 17 23260 Kit Locking Clip with mounting screw X X 18 23159 System Base X X 19 23172 Thimble Filter X X 20 23221 Plug 1 4 N...

Страница 42: ...3060 Wall Bracket 8 23061 1 to Reducing Bushing 9 23183 Mini Ball Valve Plug 10 23062 Mini Ball Valve 11 23104 Housing Wrench External Prefilter Service Testing Kit Parts 12 23104 Housing Wrench Exter...

Страница 43: ......

Отзывы: