Select Location

Select a location for the filter that is:

protected from freezing.

not exposed to direct sunlight.

It is recommended that a shut-off valve be placed on both sides 
of the filter.

Install Fittings

Instructions are for installing fittings supplied with the 
filter (on some models) or the WHKIT onto 3/4

copper

plumbing. If the unit is to be installed on any other type of
tubing (plastic, PVC, galvanized), different hardware must be
purchased. See instructions with additional hardware
purchased, or consult a qualified plumber.

Apply about 6

of Teflon

®

tape, in a clockwise direction, to 

the pipe threads (course) of each adapter. 

DO NOT

use joint

compound on any parts.

Assemble an adapter to the inlet and outlet of the head. 
Start each fitting by hand to make sure they don’t cross
thread. Use a 1

1

8

wrench firmly. 

DO NOT OVERTIGHTEN.

About one to two thread(s) should remain visible.

Cut Water Line

Turn off water supply and open a nearby faucet to drain
water out of pipes.

Remove the nut and brass ferrule from both compression
fittings and set aside. Using a tape measure or ruler,
measure the distance “D” as shown.

NOTE: 

It is recommended that the shut-off valve be placed

before and after the filter as shown in the 

Installation

Overview

illustration.

Select the location for the filter. Mark the distance “D” 
on the pipe.

Using a pipe cutter or hacksaw, cut pipe. Sand (file) cut
ends of pipe to assure that they are square and smooth.

3

2

1

Attach Fittings to Water Line

Slip a compression nut onto each pipe.

Next, slip the brass ferrule onto each pipe.

2

1

Nut

Brass ferrule

Nut

Brass ferrule

Measure to shoulder 

of fittings. Copper
pipe butts against

this shoulder.

D

D

GXWH01C

GXWH08C

Installing the Ground Wire

IMPORTANT:

A copper or galvanized house cold water pipe is often

used to ground electrical outlets in the home. 

Grounding protects you

from electrical shock.

The water filter housing may have broken this

ground path. To restore connection, install a 12

″ 

long, 8-gauge

copper wire across the filter, tightly clamped using UL-approved
1/2

–1

bronze grounding clamps at both ends as shown. Zinc

clamps should not be used on copper plumbing. For 

GXWH01C

,

wire and clamps may be purchased separately from your local
hardware store, or are available by visiting our Website at
www.GEAppliances.com, or from Parts and Accessories by calling
800.626.2002 (U.S.)or 800.663.6060 (Canada) – order part 
number WHKIT.

Clean copper pipe and ends of wire with emery paper. Bare wire
is recommended. If insulated wire is used, it should be stripped
3/4

at each end before cleaning with emery paper.

Attach bronze clamps to copper pipe. Tighten screws.

Attach wire to clamps as shown. Tighten screws.

NOTE: 

If your house plumbing is plastic, it would not be used as a

grounding path, and this step should be skipped. 

3

2

1

Clamp

Final Check

Install filter, if not all ready done. (See Filter Cartridge
Replacement section.)
Slowly turn on water supply.

Check entire system for leaks.

If leaking, shut off water pressure and tighten or reseal
fittings.
Open any downstream faucet and allow filter system to
flush for 5 minutes.

5

4

3

2

1

D

Ground wire

Teflon

®

tape

Installing the Unit

Align filter assembly with pipe ends making certain that the

incoming

water supply is going into the filter opening marked

“IN”. It may be necessary to spread the pipe ends apart to install
filter assembly.

Using a 1

1

8

wrench to hold the adapter in place, use a 1

1

4

wrench to tighten the nut. Repeat process for other fittings.
If necessary, support the water pipe on either side of the filter
unit.

3

2

1

Содержание GXWH01C

Страница 1: ...obiologically unsafe or of unknown quality without adequate disinfection before or after the system It is highly recommended that a water shut off valve be placed directly upstream of your household filter PROPER INSTALLATION Check with your local public works department for plumbing codes You must follow their guides as you install the Household Water Filtration System Use the Household Water Fil...

Страница 2: ...sure it is lightly lubricated and completely seated in the groove It is recommended that you replace the O ring if it is damaged Place a new filter cartridge into the canister making sure it is centered and completely seated on the bottom seal Reinstall the filter canister to the unit Hand tightening is all that is required to seal the unit Slowly turn on water to the filter by using the bypass va...

Страница 3: ...his shoulder D D GXWH01C GXWH08C Installing the Ground Wire IMPORTANT A copper or galvanized house cold water pipe is often used to ground electrical outlets in the home Grounding protects you from electrical shock The water filter housing may have broken this ground path To restore connection install a 12 long 8 gauge copper wire across the filter tightly clamped using UL approved 1 2 1 bronze gr...

Страница 4: ...d by GE Liability on the part of GE under this or any other warranty for any indirect or consequential damage Products that are used for commercial or industrial applications Use of this product where water is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected water that may contain...

Страница 5: ...s utiliser ce produit avec de l eau microbiologiquement polluée ou de qualité inconnue sans avoir installé un dispositif de désinfection approprié avant ou après le système On recommande fortement l installation d un robinet d arrêt directement en amont du système de filtration INSTRUCTIONS D INSTALLATION Consulter le service local des travaux publics au sujet des codes de plomberie L installation...

Страница 6: ...ce qu il soit légèrement lubrifié et bien emboîté dans la rainure Remplacer le joint torique s il est endommagé Placer la nouvelle cartouche de filtration dans le corps de filtre placer correctement et bien centrer la cartouche sur le joint du fond Revisser le corps de filtre sur la tête Il suffit de serrer à la main Rétablir lentement l arrivée d eau au filtre avec le robinet de dérivation modèle...

Страница 7: ...roide en cuivre ou en métal galvanisé pour effectuer une liaison à la terre des prises électriques de la maison Cette mise à la masse vous protège contre les chocs électriques et cette liaison à la terre peut voir été neutralisée par le logement du filtre d eau Pour rétablir la connexion montez un fil en cuivre de 12 po et de calibre 8 le long du filtre lequel sera fixé solidement au moyen d attac...

Страница 8: ...e ou tout dommage non imputable à GE Responsabilité de GE couvert par cette garantie ou toute autre garantie couvrant tout dommage indirect Produits utilisés pour des applications industrielles ou commerciales Utilisation de ce produit lorsque l eau est microbiologiquement impure ou de qualité inconnue sans qu une désinfection adéquate n ait eu lieu avant l entrée et sortie dans le circuit Les sys...

Страница 9: ... agua cumple con las Guías de Especificaciones Si las condiciones del abastecimiento de agua son desconocidas póngase en contacto con su compañía de agua municipal ADVERTENCIA No use con agua que sea bacteriológicamente insegura o de calidad desconocida sin una desinfección adecuada antes o después del sistema Es altamente recomendado que la válvula de cierre sea colocada directamente hacia arriba...

Страница 10: ...lo si está dañado Coloque un filtro nuevo en el receptáculo asegurándose de que esté centrado y completamente asentado sobre el fondo del sello Reinstale el receptáculo del filtro a la unidad Apretarlo con la mano es todo lo que se necesita para sellar la unidad Lentamente abra el paso del agua hacia el filtro usando la válvula tipo bypass modelo GXWH08C o en la válvula de cierre paso arriba Empuj...

Страница 11: ...macorrientes eléctricos en las casas Una toma de tierra lo protege de descargas eléctricas El alojamiento del filtro de agua pudo haber interrumpido la trayectoria de tierra Para restablecer la conexión instale un cable de cobre de 12 de calibre 8 a través del filtro fuertemente sujeto utilizando abrazaderas de tierra de bronce de 1 2 a 1 aprobada por UL en ambos extremos de la línea como se muest...

Страница 12: ...ualquier otra garantía por cualquier daño indirecto o por consecuencia de otro evento Productos que son usados con fines comerciales o industriales Uso de este producto donde el agua está microbiológicamente insegura o de calidad desconocida sin la adecuada desinfección antes y después de ser procesada por el sistema Los sistemas certificados para reducir el nivel de quistes pueden ser usados en a...

Отзывы: