background image

Performance Data Sheet.

SmartWater Filtration System GXSL55F 
Using Filter FQSLF

This System has been tested according to NSF/ANSI 42 and 53 for the
reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as
specified in NSF/ANSI 42 and 53.

Actual performance may vary with local water conditions.

Do not use with water that is microbiologically unsafe or with water of
unknown quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected waters that
may contain filterable cysts.

Hoja de datos de funcionamiento.

Cartucho FQSLF de sistema de filtración 
GE SmartWater GXSL55F

Este sistema se ha sometido a las pruebas NSF/ANSI 42 y 53 a fin de reducir
las sustancias presentadas a continuación. Se redujo la concentración 
de las sustancias indicadas en el agua que ingresan en el sistema a una
concentración menor o igual al limite permitido para el agua que sale del
sistema, como se especifica en NSF/ANSI 42 y 53.

El desempeño real puede variar de acuerdo a las condiciones locales 
del agua.

No use con agua que sea microbiológicamente insegura o de calidad
desconocida sin una desinfección adecuada del sistema antes o después.
Los sistemas certificados para la reducción de esporas pueden ser usados
en agua desinfectada que podría contener esporas filtrables.

Standard No. 42: Aesthetic Effects / Estándar No. 42: Efectos estéticos

USEPA

Influent

Influent

Effluent

% Reduction

Min. Required

Parameter

MCL

Challenge Concentration

Average

Average

Maximum

Average

Minimum

Reduction

USEPA

Calidad del

Promedio

Effluyente

% de reducción

Reducción

Parámetro

MCL

influyente concentración

influyente

Promedio

Máximo

Promedio

Mínimo

mínima necesaria

Chlorine/Cloro

2.0 mg/L ± 10%

1.89 mg/L

<0.05 mg/L

0.06 mg/L

>97.29%

96.84%

≥50%

T & O

Particulate**/

≥ 10000 particles/

5700000 #/mL

30583 #/mL

69000 #/mL

99.52%

98.94%

≥85%

Partículas

partículas/mL

Standard No. 53: Health Effects / Estándar No. 53: Efectos relativos a la salud

USEPA

Influent

Influent

Effluent

% Reduction

Min. Required

Parameter

MCL

Challenge Concentration

Average

Average

Maximum

Average

Minimum

Reduction

USEPA

Calidad del

Promedio

Effluyente

% de reducción

Reducción

Parámetro

MCL

influyente concentración

influyente

Promedio

Máximo

Promedio

Mínimo

mínima necesaria

Turbidity/Turbidez

1 NTU***

11 ± 1 NTU***

10.73 NTU

0.311 NTU

0.49 NTU

97.08%

95.15%

0.5 NTU

Cysts/Quistes

99.95% red.

Min. 50000L

166500 #/L

<1

<1

>99.99%

>99.99%

>99.95%

Asbestos/Amianto

99% red.

10

7

and/y 10

8

fibers/fibras/L;

155 MF/L

<1

<1

>99.99%

>99.99%

99%

fibers/fibras >10 µm

long/de largo

Lead/Plomo,

0.015 mg/L

0.15 mg/L ± 10%

0.152 mg/L

<0.001

<0.001

>99.34%

>99.29%

0.01 mg/L

pH 6.5
Lead/Plomo,

0.015 mg/L

0.15 mg/L ± 10%

0.148 mg/L

<0.001

<0.001

>99.31%

>99.29%

0.01 mg/L

pH 8.5
Mercury/Mercurio,

0.002 mg/L

0.006 mg/L ± 10%

0.006 mg/L

0.00024

0.0005

98.72%

99.31%

0.002 mg/L

pH 6.5
Mercury/Mercurio,

0.002 mg/L

0.006 mg/L ± 10%

0.006 mg/L

0.0007

0.0013

87.37%

79.63%

0.002 mg/L

pH 8.5
Lindane

0.0002 mg/L

0.002 mg/L ± 10%

0.002 mg/L

0.000025

0.00002

98.97%

98.89%

0.0002 mg/L

Toxaphene

0.003 mg/L

0.015 ± 10%

0.015 mg/L

<0.001

<0.001

93.23%

91.67%

0.003 mg/L

2,4-D

0.0017 mg/L

0.021 mg/L ± 10%

0.222 mg/L

0.01422 mg/L

0.059 mg/L

93.14%

70.50%

0.0017 mg/L

Atrazine

0.003 mg/L

0.009 mg/L ± 10%

0.00886 mg/L

<0.002

<0.002

77.33%

76.61%

0.003 mg/L

*Tested using a flow rate of 0.78 gpm (2.95 l/min); pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 3°C) / Probado utilizando una tasa de flujo de 0,78 gpm (2,95 l/min); presión de 60 psig; pH

de 7,5 ± 0,5; temp. de 68° ± 5° F (20° ± 3° C)

**Measurement in particles/mL. Particles used were 0.5–1 microns. / Medición en partículas/mL. Las partículas usadas eran de 0,5–1 micrón.
***NTU—Nephelometric Turbidity Units / NTU—unidades de turbidez nefelométrica

Operating Specifications / Especificaciones de operación

Capacity: certified for up to 1200 gallons (4,542 l); up to six months / Capacidad: certificado para hasta 1200 galones (4542 l); hasta seis meses
Pressure requirement: 35–120 psi (2.8–8.2 bar) / Requerimientos de presión: 35–120 psi (2,8–8,2 bar)
Temperature: 33–100°F (0.6–38°C) / Temperatura: 33°–100° F (0,6°–38° C)
Flow rate: 0.78 gpm (2.95 l/min) / Tasa de flujo: 0,78 gpm (2,95 l/min)

Replacement Filter Canisters/Estimated Replacement Costs

FQSLF—Replacement filter canister $30–35

For replacement parts, call toll-free 800.626.2002.

Repuesto de los cartuchos de los filtros/Costos estimados de reposición

FQSLF—Repuesto del cartucho del filtro $30–35

Para repuestos, llame gratis al 800.626.2002 (EE.UU.).

5

Содержание GXSL55F

Страница 1: ...tional against NSF ANSI Standard 42 for the reduction of Chlorine Taste and Odor and Particulate Class I and Standard 53 for the reduction of Lead Cyst Turbidity Asbestos Mercury Lindane Atrazine Toxa...

Страница 2: ...AD IMPORTANTE LEA TODAS LAS INSTRUCCIONES ANTES DE USAR ADVERTENCIA Para su seguridad se deber seguir la informaci n de este manual para minimizar el riesgo de da os a la propiedad o lesiones personal...

Страница 3: ...Sheet for details Pautas de las especificaciones Se pueden reducir muchos malos olores y o sabores del agua usando cartuchos de carbono para el filtro Se usan principalmente para reducir el olor y sa...

Страница 4: ...forma a las normas 42 y 53 NSF ANSI en cuanto a las afirmaciones espec ficas de desempe o seg n verificaci n y admisi n de los datos de las pruebas Consulte la hoja de datos del desempe o para detalle...

Страница 5: ...rameter MCL Challenge Concentration Average Average Maximum Average Minimum Reduction USEPA Calidad del Promedio Effluyente de reducci n Reducci n Par metro MCL influyente concentraci n influyente Pro...

Страница 6: ...relativos a la salud Turbidity Turbidez 1 NTU 11 1 NTU 11 08 NTU 0 21 NTU 0 38 NTU 98 04 96 20 0 5 NTU Cysts Quistes 99 95 red Min 50000L 141750 L 1 L 2 L 99 99 99 99 99 95 Asbestos Amianto 99 red 107...

Страница 7: ...je de la reducci n qu mica y el nivel m ximo del agua del producto calculado a un punto de ruptura de 95 de cloroformo seg n lo determinado en la prueba de calificaci n sustituta 6 The surrogate test...

Страница 8: ...ber a flexible del grifo En la ilustraci n que aparece a continuaci n se muestra una conexi n t pica usando el accesorio para el suministro de agua incluido 1 Cierre la v lvula de agua que se encuentr...

Страница 9: ...r conectarse con el tubo de 1 4 de pulgada suministrado con el sistema No se suministra con el producto consulte en la ferreter a local o tienda de servicios para el hogar La v lvula de asiento t pica...

Страница 10: ...ada por bater a Seleccione uno de los siguientes lugares para instalar el grifo 1 En un orificio accesorio rociador existente en el lavaplatos u orificio de dispensador de jab n 2 En un orificio a per...

Страница 11: ...base de los cartuchos de los filtros y el piso o la base del gabinete cualquier espacio inferior presentar dificultades para retirar los cartuchos de los filtros Fig 5 Permita suficiente espacio para...

Страница 12: ...ntil a desired fit is achieved Instrucciones de instalaci n Montaje del sistema Montaje del sistema a los tornillos instalados en la pared 1 Remueva la envoltura de pliegue del sistema del filtro 2 Cu...

Страница 13: ...z Fig 8 Revise que quede pareja lisa y que no tenga cortes hendiduras puntos planos o bordes filosos 2 NOTA El flujo de agua es de izquierda a derecha La entrada del agua est en el lado izquierdo y la...

Страница 14: ...i n de la bater a 1 Use un destornillador de pala plana peque o o una moneda para retirar la bandeja de la bater a A en el costado de la base del grifo 2 Instale una bater a CR2032 de 3 voltios B con...

Страница 15: ...leaks around the system 5 Once water starts to flow out of the faucet allow the system to run for 5 minutes to flush out any harmless carbon fines that may be present 6 Turn off faucet and check arou...

Страница 16: ...link rapidly 5 times to indicate proper installation and operation Indicator light on the Battery may need to be Observe orientation markings on the holder and install correctly faucet base is not rep...

Страница 17: ...5 veces para indicar la instalaci n y operaci n correcta La luz indicadora La bater a podr a necesitar Observe las marcas de orientaci n en el recept culo e instale en la base del grifo reemplazo o po...

Страница 18: ...Notes Notas 18...

Страница 19: ...usted prefiera El registrar su producto a tiempo le proporcionar si surgiera la necesidad una mejor comunicaci n y un servicio m s r pido bajo los t rminos de su garant a Tambi n puede enviar su tarje...

Страница 20: ...n will allow for enhanced communication and prompt service under the terms of your warranty should the need arise You may also mail in the preprinted registration card included in the packing material...

Отзывы: