Outlet Control Thermistor
Operation of the outlet control
thermistor
can be checked by using
service test mode T05.
Specific failures associated with the
outlet control thermistor
can initiate
error codes E5 and E6.
To remove the outlet control thermistor:
1. Remove the drum.
2. Remove the Phillips-head screw and the thermostat moisture shield from
the front frame.
3. Disconnect the 2 wires from the outlet control thermistor.
4. Remove the 2 Phillips-head screws that attach the outlet control
thermistor
to the blower housing.