Installation Instructions
INSTALLATION CHECKLIST
1. Tank location:
– Is
room size
less than 10' x 10' x 7' (700 cu. ft.)? If yes, louvered door or similar ventilation is needed.
– Back of unit
away from wall
by 7 inches.
–
Front
of unit is free and clear.
– Is the water heater
level
? If no, add shims under the base of the unit.
2. Plumbing connections:
– Does not prevent
air filter
removal.
– No leaks after
filling
the tank with water, either when water is flowing or not.
3. Condensate lines are in place:
1) Short tube on upper drain nozzle.
2) Longer tube on lower drain nozzle and directed into a floor drain or a condensate pump.
4. Temperature and pressure-relief valve
is working and drain line completed per local code.
5. Electrical
connection does not prevent air filter removal.
6.
Verify
control panel
displays 120°F Hybrid mode.
7.
Front
cover
is in place.