3
Figure 5. Close Coil Plug assembly
8. Ensure the plug is inserted properly by the
snap in the secondary disconnect.
9.
Place the ferrite from the coil assembly behind
the coil. Route the wire from the close coil to the
side of the PMU base for the connection with
Electrical close switch as shown in fig.6.
Figure 6. Close Coil wire routing
Installation of Electrical close switch:
10.
Slide the switch assembly over the
mechanism side sheet and locate in the two
locating holes as shown in Fig. 7.
Figure 7. EC switch assembly
11.
Assemble the screw with washer as shown
in Fig. 8. Tighten the screw to torque
2Nm(1.47ft-lbs).
Figure 8. Screw assembly
12. Plug the connector from the EC switch
assembly to the connector from the command
closing coil beside the PMU base as shown in
Fig 9.
Figure 9. Connector plug assembly