background image

7

Installation Instructions

3-WIRE CONDUIT INSTALLATION

Loosen the 3 lower terminal screws from
the terminal block. Insert the center bare
wire (white/neutral) tip through the bottom
center terminal block opening. On certain
models, the wire will need to be inserted
through the ground strap opening and then
into the bottom center block opening. Insert
the two side bare wire tips into the lower
left and the lower right terminal block
openings. Tighten the screws until the wire
is firmly secured (35 to 50 inch-lbs.). Do not
over-tighten the screws since it could
damage the wires.

NOTE: ALUMINUM WIRING:

Aluminum building wire may be used
but it must be rated for the correct
amperage and voltage to make
connection. Connect wires according 
to this Step 6 or Step 7 depending on
number of wires.

Wire used, location and enclosure 
of splices, etc., must conform to good
wiring practices and local codes.

Skip to Step 8 and proceed with the
installation.

B

A

6

4-WIRE CONDUIT INSTALLATION

Loosen the three lower terminal screws
from the terminal block. Remove the ground
screw and ground plate and retain them. 

Cut and discard the ground strap. DO NOT
DISCARD ANY SCREWS.

Insert the ground bare wire tip between the
range frame and the ground plate (removed
earlier) and secure it in place with the ground
screw (removed earlier). Insert the bare wire
(white/neutral) tip through the bottom center
of the terminal block opening. Insert the two
side bare wire tips into the lower left and the
lower right terminal block openings. Tighten
the screws until the wire is firmly secured
(35 to 50 inch-lbs.). Do not over-tighten the
screws since it could damage the wires.

Wire used, location and enclosure 
of splices, etc., must conform to good
wiring practices and local codes.

Proceed to Step 8.

C

B

A

7

Before

Terminal
block

Ground strap

After

Terminal
block

Ground
plate
(grounding
to range)

Bracket

Neutral
terminal

Wire tips

Wire tips

Terminal
block

Conduit

Bracket

Ground
screw

Ground strap 

or

Содержание Free-Standing Ranges

Страница 1: ...e beginning the installation switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel ANTI TIP DEVICE WARNING To reduce the risk of tipping the appliance must be secured by properly installed Anti ...

Страница 2: ...st be no deeper than 13 Be sure your appliance is properly installed and grounded by a qualified technician Make sure the cabinets and wall coverings around the range can withstand the temperatures up to 200 F generated by the range 2 Installation Instructions PREPARE TO INSTALL THE RANGE MATERIALS YOU MAY NEED Anchor Sleeves Lag Bolts For Anti Tip Bracket Mounted on Concrete Floors Only 3 Wire Co...

Страница 3: ...OVE THE COOKTOP Make sure the wall covering countertop flooring and cabinets around the range can withstand the heat up to 200 F generated by the range Allow 30 minimum clearance between surface units and bottom of unprotected wood or metal cabinet and 15 minimum between countertop and adjacent cabinet bottom Recommended spacing to heat sensitive surfaces 2 21 2 21 2 71 2 25 36 30 Acceptable elect...

Страница 4: ...MENTS CAUTION For personal safety do not use an extension cord with this appliance Remove house fuse or open circuit breaker before beginning installation This appliance must be supplied with the proper voltage and frequency and connected to an individual properly grounded branch circuit protected by a circuit breaker or fuse having amperage appropriate for the wattage specified on the rating plat...

Страница 5: ...strain relief they can be removed for better fit NOTE Do not install the power cord without a strain relief The strain relief bracket should be installed before reinstalling the rear range wiring cover Skip to Step 4 or 5 C Wire cover 5 screws to remove wire cover Knockout ring in bracket Knockout ring removed Power cord Strain relief Terminal block Bracket Retaining tabs Back of range Terminal bl...

Страница 6: ...tral is connected to the center lower position of the terminal block Tighten screws securely into the terminal block Skip to Step 8 and proceed with the installation E D C B A 5 3 WIRE POWER CORD INSTALLATION WARNING The neutral or ground wire of the power cord must be connected to the neutral terminal located in the center of the terminal block The power leads must be connected to the lower left ...

Страница 7: ...local codes Skip to Step 8 and proceed with the installation B A 6 4 WIRE CONDUIT INSTALLATION Loosen the three lower terminal screws from the terminal block Remove the ground screw and ground plate and retain them Cut and discard the ground strap DO NOT DISCARD ANY SCREWS Insert the ground bare wire tip between the range frame and the ground plate removed earlier and secure it in place with the g...

Страница 8: ... liquids or from the range itself 9 Typical installation of anti tip bracket attachment to wall Bracket Screw must enter wood or metal Wall plate REPLACE THE WIRE COVER Replace the wire cover on the range back by sliding its left edge under the retaining tabs and replacing the five screws removed earlier Make sure that no wires are pinched between the cover and the range back 8 REMOVE STORAGE DRAW...

Страница 9: ...e door and drawer are parallel to each other and that both operate smoothly If they do not see the Owner s Manual for proper replacement Check to make sure that the rear leveling leg is fully inserted into the Anti Tip bracket and that the bracket is securely installed 14 OPERATION CHECKLIST Turn on one of the surface units to observe that the element glows within 60 seconds Turn the unit off when...

Страница 10: ...10 Notes ...

Страница 11: ...11 Notes ...

Страница 12: ...12 Printed in the United States ...