Installation Instructions

POWER CORD AND 
STRAIN RELIEF INSTALLATION

Remove the wire cover (on the back of
the range) by removing five (5) screws
using a 1/4” nut driver.

Do not discard these screws.

Remove the knockout ring (1

3

8

) located

on bracket directly below the terminal
block. To remove the knockout, use a
pair of pliers to bend the knockout ring
away from the bracket and twist until
ring is removed.

B

A

3

For power cord installations only

(see

the next step if using conduit), assemble
the strain relief in the hole. Insert the
power cord through the strain relief and
tighten. Allow enough slack to easily
attach the cord terminals to the terminal
block. If tabs are present at the end of
the winged strain relief, they can be
removed for better fit.

NOTE: Do not install the power cord
without a strain relief. The strain relief
bracket should be installed before
reinstalling the rear range wiring cover.

Skip to Step 4 or 5.

C

Wire cover

5 screws
to remove
wire cover

Knockout ring
in bracket

Knockout
ring removed

Power cord

Strain relief

Terminal
block

Bracket

Retaining
tabs

Back of range

Terminal block
(appearance
may vary)

For conduit installations only

, purchase a

squeeze connector matching the diameter
of your conduit and assemble it in the hole.
Insert the conduit through the squeeze
connector and tighten. Allow enough slack to
easily attach the wires to the terminal block.

NOTE: 

Do not install the conduit without a

squeeze connector. The squeeze connector
should be installed before reinstalling the
rear range wiring cover.

Skip to Step 6 or 7.

D

Squeeze

connector

Terminal
block

Conduit

Bracket

Содержание Free-Standing Ranges

Страница 1: ...e beginning the installation switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel ANTI TIP DEVICE WARNING To reduce the risk of tipping the appliance must be secured by properly installed Anti ...

Страница 2: ...st be no deeper than 13 Be sure your appliance is properly installed and grounded by a qualified technician Make sure the cabinets and wall coverings around the range can withstand the temperatures up to 200 F generated by the range 2 Installation Instructions PREPARE TO INSTALL THE RANGE MATERIALS YOU MAY NEED Anchor Sleeves Lag Bolts For Anti Tip Bracket Mounted on Concrete Floors Only 3 Wire Co...

Страница 3: ...OVE THE COOKTOP Make sure the wall covering countertop flooring and cabinets around the range can withstand the heat up to 200 F generated by the range Allow 30 minimum clearance between surface units and bottom of unprotected wood or metal cabinet and 15 minimum between countertop and adjacent cabinet bottom Recommended spacing to heat sensitive surfaces 2 21 2 21 2 71 2 25 36 30 Acceptable elect...

Страница 4: ...MENTS CAUTION For personal safety do not use an extension cord with this appliance Remove house fuse or open circuit breaker before beginning installation This appliance must be supplied with the proper voltage and frequency and connected to an individual properly grounded branch circuit protected by a circuit breaker or fuse having amperage appropriate for the wattage specified on the rating plat...

Страница 5: ...strain relief they can be removed for better fit NOTE Do not install the power cord without a strain relief The strain relief bracket should be installed before reinstalling the rear range wiring cover Skip to Step 4 or 5 C Wire cover 5 screws to remove wire cover Knockout ring in bracket Knockout ring removed Power cord Strain relief Terminal block Bracket Retaining tabs Back of range Terminal bl...

Страница 6: ...tral is connected to the center lower position of the terminal block Tighten screws securely into the terminal block Skip to Step 8 and proceed with the installation E D C B A 5 3 WIRE POWER CORD INSTALLATION WARNING The neutral or ground wire of the power cord must be connected to the neutral terminal located in the center of the terminal block The power leads must be connected to the lower left ...

Страница 7: ...local codes Skip to Step 8 and proceed with the installation B A 6 4 WIRE CONDUIT INSTALLATION Loosen the three lower terminal screws from the terminal block Remove the ground screw and ground plate and retain them Cut and discard the ground strap DO NOT DISCARD ANY SCREWS Insert the ground bare wire tip between the range frame and the ground plate removed earlier and secure it in place with the g...

Страница 8: ... liquids or from the range itself 9 Typical installation of anti tip bracket attachment to wall Bracket Screw must enter wood or metal Wall plate REPLACE THE WIRE COVER Replace the wire cover on the range back by sliding its left edge under the retaining tabs and replacing the five screws removed earlier Make sure that no wires are pinched between the cover and the range back 8 REMOVE STORAGE DRAW...

Страница 9: ...e door and drawer are parallel to each other and that both operate smoothly If they do not see the Owner s Manual for proper replacement Check to make sure that the rear leveling leg is fully inserted into the Anti Tip bracket and that the bracket is securely installed 14 OPERATION CHECKLIST Turn on one of the surface units to observe that the element glows within 60 seconds Turn the unit off when...

Страница 10: ...10 Notes ...

Страница 11: ...11 Notes ...

Страница 12: ...12 Printed in the United States ...

Отзывы: