ELECTRICAL CONNECTIONS 

(CONT.)

4-WIRE POWER CORD
INSTALLATION

WARNING: 

The neutral wire of 

the supply circuit must be connected to the
neutral terminal located in the lower center
of the terminal block. The power leads must
be connected to the lower left and the lower
right terminals of the terminal block. The 4th
grounding lead must be connected to the
frame of the range with the ground plate 
and the ground screw.

Remove the 3 lower terminal screws from
the terminal block. Remove the ground
screw and ground plate and retain them.

Cut and discard the ground strap. DO NOT
DISCARD ANY SCREWS.

Insert the one ground screw into the power
cord ground wire terminal ring, through the
ground plate and into the frame of the range.

Insert the 3 terminal screws (removed earlier)
through each power cord terminal ring and
into the lower terminals of the terminal block.
Be certain that the center wire (white/neutral)
is connected to the center lower position of
the terminal block. Tighten screws securely
into the terminal block.

Skip to Step 8 and proceed with the installation.

E

D

C

B

A

5

3-WIRE POWER CORD
INSTALLATION

WARNING: 

The neutral or ground

wire of the power cord must be connected
to the neutral terminal located in the
center of the terminal block. The power
leads must be connected to the lower left
and the lower right terminals of the
terminal block.

Remove the 3 lower terminal screws
from the terminal block. Insert the 3
terminal screws through each power cord
terminal ring and into the lower terminals
of the terminal block. Be certain that the
center wire (white/neutral) is connected
to the center lower position of the
terminal block. Tighten screws securely
into the terminal block.

DO NOT remove the ground strap
connection.

Skip to Step 8 and proceed with the
installation.

B

A

4

Ground
strap

Terminal
block 
(appearance
may vary)

Neutral
terminal

Power cord

Before

After

Terminal
block

Terminal
block

Neutral
terminal

Neutral terminal

Ground strap

Ground
plate
(grounding
to range)

Ground
screw

Ground strap 

Ground
plate

or

Содержание Free-Standing Ranges

Страница 1: ...e beginning the installation switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel ANTI TIP DEVICE WARNING To reduce the risk of tipping the appliance must be secured by properly installed Anti ...

Страница 2: ...st be no deeper than 13 Be sure your appliance is properly installed and grounded by a qualified technician Make sure the cabinets and wall coverings around the range can withstand the temperatures up to 200 F generated by the range 2 Installation Instructions PREPARE TO INSTALL THE RANGE MATERIALS YOU MAY NEED Anchor Sleeves Lag Bolts For Anti Tip Bracket Mounted on Concrete Floors Only 3 Wire Co...

Страница 3: ...OVE THE COOKTOP Make sure the wall covering countertop flooring and cabinets around the range can withstand the heat up to 200 F generated by the range Allow 30 minimum clearance between surface units and bottom of unprotected wood or metal cabinet and 15 minimum between countertop and adjacent cabinet bottom Recommended spacing to heat sensitive surfaces 2 21 2 21 2 71 2 25 36 30 Acceptable elect...

Страница 4: ...MENTS CAUTION For personal safety do not use an extension cord with this appliance Remove house fuse or open circuit breaker before beginning installation This appliance must be supplied with the proper voltage and frequency and connected to an individual properly grounded branch circuit protected by a circuit breaker or fuse having amperage appropriate for the wattage specified on the rating plat...

Страница 5: ...strain relief they can be removed for better fit NOTE Do not install the power cord without a strain relief The strain relief bracket should be installed before reinstalling the rear range wiring cover Skip to Step 4 or 5 C Wire cover 5 screws to remove wire cover Knockout ring in bracket Knockout ring removed Power cord Strain relief Terminal block Bracket Retaining tabs Back of range Terminal bl...

Страница 6: ...tral is connected to the center lower position of the terminal block Tighten screws securely into the terminal block Skip to Step 8 and proceed with the installation E D C B A 5 3 WIRE POWER CORD INSTALLATION WARNING The neutral or ground wire of the power cord must be connected to the neutral terminal located in the center of the terminal block The power leads must be connected to the lower left ...

Страница 7: ...local codes Skip to Step 8 and proceed with the installation B A 6 4 WIRE CONDUIT INSTALLATION Loosen the three lower terminal screws from the terminal block Remove the ground screw and ground plate and retain them Cut and discard the ground strap DO NOT DISCARD ANY SCREWS Insert the ground bare wire tip between the range frame and the ground plate removed earlier and secure it in place with the g...

Страница 8: ... liquids or from the range itself 9 Typical installation of anti tip bracket attachment to wall Bracket Screw must enter wood or metal Wall plate REPLACE THE WIRE COVER Replace the wire cover on the range back by sliding its left edge under the retaining tabs and replacing the five screws removed earlier Make sure that no wires are pinched between the cover and the range back 8 REMOVE STORAGE DRAW...

Страница 9: ...e door and drawer are parallel to each other and that both operate smoothly If they do not see the Owner s Manual for proper replacement Check to make sure that the rear leveling leg is fully inserted into the Anti Tip bracket and that the bracket is securely installed 14 OPERATION CHECKLIST Turn on one of the surface units to observe that the element glows within 60 seconds Turn the unit off when...

Страница 10: ...10 Notes ...

Страница 11: ...11 Notes ...

Страница 12: ...12 Printed in the United States ...

Отзывы: